IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint,
paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These
OBSERVED PROBLEM
Heater produces a clicking/tick-
ing noise just after burner is lit or
shut off
Heater produces unwanted odors
Heater shuts off in use (ODS
operates)
Gas odor even when control knob
is in OFF position
Gas odor during combustion
112882-01D
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Metal expanding while heating
or contracting while cooling
1. Heater burning vapors from
paint, hair spray, glues, clean-
ers, chemicals, new carpet,
etc. (See IMPORTANT state-
ment above)
2. Gas leak. See Warning
statement above
1. Not enough fresh air is
available
2. Low line pressure
3. O D S / p i l o t i s p a r t i a l l y
clogged
1. Gas leak. See Warning
statement above
2. Control valve defective
1. Foreign matter between con-
trol valve and burner
2. Gas leak. See Warning
statement above
www.desatech.com
REMEDY
1. This is common with most heat-
ers. If noise is excessive, contact
qualified service person
1. Open window and ventilate
room. Stop using odor causing
products while heater is running
2. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 15)
1. Open window and/or door for
ventilation
2. Contact local natural or pro-
pane/LP gas company
3. Clean ODS/pilot (see Cleaning
and Maintenance, page 23)
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 15)
2. Replace control valve
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 15)