Desa VGL18NRA Owner's Operation And Installation Manual page 12

Unvented (vent-free) gas log heater also design-certified as vented decorative appliances when not used with hand-held thermostat remote
Table of Contents

Advertisement

INSTALLATION
Continued
FLOOR CLEARANCES
A. If installing appliance on the floor level, you
must maintain the minimum distance of 14"
to combustibles (see Figure 8).
B. If combustible materials are less than 14" to
the fireplace, you must install appliance at
least 5" above the combustible flooring (see
Figure 9).
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
INSTALLING DAMPER CLAMP
ACCESSORY FOR VENTED
OPERATION
Note: When used as a vented heater, appliance
must be installed only in a solid-fuel burning
fireplace with a working flue and constructed of
noncombustible material.
If you choose to use your heater as a manually-
controlled model (no remote control installed),
you may use this heater as a vented product. There
are three reasons for operating your heater in the
vented mode.
1. The fireplace does not meet the clearance
to combustibles requirements for vent-free
operation.
12
Combustible
Material
14"
Min.
Noncombustible Material
Hearth
Combustible
Material
5"
Min.
www.desatech.com
2. State or local codes do not permit vent-free
operation.
3. You prefer vented operation.
If reasons number 1 or 2 above apply to you, you
must permanently open chimney flue damper. You
must install the damper clamp accessory (to order,
see Accessories, page 29). This will insure vented
operation (see Figure 10). The damper clamp will
keep damper open. Installation instructions are
included with clamp accessory.
See chart below for minimum permanent flue
opening you must provide. Attach damper clamp
so the minimum permanent flue opening will be
maintained at all times.
Chimney
Height (ft.)
6' to 15'
15' to 30'
Area of Various
Standard
Round Flues
Diameter
(inches)
5
6
7
8
Damper
Clamp
Damper
Masonry Fireplace
Figure 10 - Attaching Damper Clamp
Minimum
Permanent Flue
Opening (sq. ins.)
39 sq. inches
29 sq. inches
Area
(sq. inches)
20
29
39
51
Damper
Manufactured
Fireplace
112882-01D