Desa VGC18NR/PR Owner's Operation And Installation Manual page 9

Unvented (vent-free) gas log heater
Hide thumbs Also See for VGC18NR/PR:
Table of Contents

Advertisement

INSTALLATION
Continued
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls
or cause odors.
IMPORTANT: Vent-free heaters add moisture to
the air. Although this is beneficial, installing heater
in rooms without enough ventilation air may cause
mildew to form from too much moisture. See Air
for Combustion and Ventilation, page 6.
CHECK GAS TYpE
Use the correct type of gas (natural or propane/LP).
If your gas supply is not the correct gas type, do
not install heater. Call dealer where you bought
heater for proper type heater.
WARNING: This appliance
is equipped for natural or pro-
pane/LP gas. Field conversion
is not permitted.
INSTALLATION AND CLEARANCES
FOR VENT-FREE OPERATION
WARNING: Maintain the
minimum clearances. If you
can, provide greater clearances
from floor, ceiling and adjoining
wall.
MINIMUM FIREpLACE CLEARANCE TO
COMBUSTIBLE MATERIALS
Log Size
Side Wall
Ceiling
Floor
119162-01A
18", 24", 30"
16"
42"
5"
www.desatech.com
LOG SIZING REQUIREMENTS
Minimum Firebox Size
Log
Size
Height
18"
19"
24"
19"
30"
19"
*Measured at 14" depth
Carefully follow the instructions below. This will
ensure safe installation into a masonry, UL127-
listed manufactured fireplace or listed vent-free
firebox.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and wall
should follow diagram in Figure 4.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
/
" from the wall. This combus-
1
2
tible material must be 4" from the side of the
fireplace cabinet (see Figure 4).
Note: When installing your gas logs into
a manufactured firebox, follow firebox
manufacturer's instructions for minimum
clearances to combustible materials.
B. Clearances from the top of the fireplace open-
ing to the ceiling should not be less than 42
inches.
Example
*Minimum 16" from Side Wall
Figure 4 - Minimum Clearance for
Combustible to Wall
Front
Depth
Width
14"
28"
14"
32"
14"
40"
Rear*
Width
20"
22"
30"
*
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vgc18nrVgc18prVgc24nrVgc24prVgc30nrVgc30pr