Table of Contents

Advertisement

- Per eventuali chiarimenti interpellare il più vicino rivenditore oppure rivolgersi direttamente a
Servizio assistenza tecnica: SPACE S.r.l - 10090 Trana Torino - Italia - Via Sangano, 48
Tel. (+39) 011 9338865 - Fax (+39) 011 9338864 - e-mail: aftersales@spacetest.com
- For any further information please contact your nearest dealer or speak directly to
Technical services: SPACE S.r.l - 10090 Trana Torino - Italia - Via Sangano, 48
Phone (+39) 011 9338865 - Fax (+39) 011 9338864 - e-mail: aftersales@spacetest.com
- Im Zweifelsfall oder bei Rückfragen wenden Sie sich bitte an den nächsten Händler oder direkt an:
Kundendienst: SPACE S.r.l - 10090 Trana Torino - Italia - Via Sangano, 48
Telefon (+39) 011 9338865 - Fax (+39) 011 9338864 - e-mail: aftersales@spacetest.com
- Pour tout renseignement complémentaire, s'adresser au distributeur le plus proche ou directement à:
Service Après-Vente: SPACE S.r.l - 10090 Trana Torino - Italia - Via Sangano, 48
Tél. (+39) 011 9338865 - Fax (+39) 011 9338864 - e-mail: aftersales@spacetest.com
- En caso de dudas, para eventuales aclaraciones, póngase en contacto con el distribuidor más próximo o diríjase directamente a:
Servicio Post-Venta: SPACE S.r.l - 10090 Trana Torino - Italia - Via Sangano, 48
Tel. (+39) 011 9338865 - Fax (+39) 011 9338864 - e-mail: aftersales@spacetest.com
SDC 2305 - C3
SDC 2306 - C3 - K
SOLLEVATORE A 2 COLONNE
2 POST LIFT
2 SÄULEN HEBEBÜHNE
ELEVATEUR 2 COLONNES
ELEVADOR DE 2 COLUMNAS
0472-M001-3-P1
TEST & SERVICE EQUIPMENT
Redatto da st. gf. Andrea Zuffa
0472-M001-3-P1 – Rev. n
Manuale valido
per i seguenti modelli:
SDC 2305
SDC 2305 C3
SDC 2306
SDC 2306 C3
SDC 2306 K
°
0 (05-2005)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SDC 2306 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Safety Devices
Padlockable Main Switch
Description of the main switch that can be locked with a padlock.
Deadman Device System
System that stops movement when the control is released.
Mechanical Emergency Stop
Mechanical stops that trigger on limit switch warning signals.
Safety Nut
Nut able to bear the same load as the main nut to allow load to reach the floor.
Nut Wear Stop
Prevents elevation beyond 30 cm if main nut wear exceeds set limits.
Transmission Chain Slackening and Breakage
Microswitch detects chain slackening or breakage; specific procedures for each.
Indication of Outstanding Risks
Highlights risks due to manufacturing according to strict standards.
Pictograms on Lift
Information regarding pictograms on the machine and replacement if damaged.
Technical Details
Pre-installation and Movement
Instructions for handling and moving the lift before installation.
Description of the Lift
Main Technical Specifications
Covers carriage translation, lifting/lowering mechanisms, and safety devices.
Suitability for Use
Product construction compliance with European Directive 98/37/CE and test coefficients.
Checking Installation Site Requirements
Installation Site Requirements
Ensures the installation area meets necessary criteria like light, ventilation, and space.
Installation
Installation Requirements
Details minimum floor requirements: concrete class, thickness, reinforcement, and load capacity.
Installation Instructions
Guidance on positioning columns, fitting chains, and ensuring verticality.
Securing Retaining Blocks to the Floor
Instructions for mounting floor fixing plugs and checking anchoring torque.
Installation of the Electric System
Steps for mounting the power column cover guard and connecting the electrical box.
Electrical Installation
Voltage Check
Verify that the system voltage corresponds to the mains voltage.
Connecting Up to the Mains
Details minimum cable cross-sections for three-phase and single-phase connections.
Cabling Connections
Instructions for passing the supply cable and connecting wires to the terminal board.
Completion and Check
Arm Stop Mechanism
Instructions for fitting stops to each arm and ensuring the arm is free when the lift is lowered.
Foot Guards Installation
Instructions for fitting the foot guards as shown in the diagram.
Dismantling Instructions
Procedures for dismantling, storing, or scrapping the machine.
Instructions for Using the Lift
Improper Use of the Lift
Details prohibited uses like lifting people, animals, or dangerous materials.
Use of Accessories
Specifies that only original accessories made by the manufacturer may be used.
Staff Training Requirements
Emphasizes that only trained and authorized personnel can operate the equipment.
Important Usage Precautions
Includes checks for dangerous situations, clean work area, and proper personal protective equipment.
Description and Function of Controls
Explains operation of controls for lifting, lowering, and emergency stop.
Emergency Drop Procedure
Procedure for lowering the load in case of power failure using specific tools.
Maintenance
Slideways Lubrication
Instructions for lubricating slideways every 3 months.
Lubrication Tanks Maintenance
Guidance on topping up lubrication tanks annually.
Main Nuts Check and Replacement
Monthly check of distance between safety nuts and rod; replace if approx. 2mm.
Bearing Lubrication
Inject grease into post lubricators every 3 months.
Chain Lubrication and Tensioning
Lubricate chain every 6 months and check tension.
Storage and Scrapping
Scrapping Procedure
Instructions for making the machine inoperative and classifying parts for disposal.

Table of Contents