Specifications; Accessories; Wiring Diagram - Desa Firewerks MPF18VNA Owner's Operation And Installation Manual

Desa owner's operation and installation manual vented decorative gas log heater mpf24vna, mpf24vpa, mpf18vna,, mpf18vpa
Hide thumbs Also See for Firewerks MPF18VNA:
Table of Contents

Advertisement

This appliance has been design certified to ANSI ZZ1.60-2003 and CSA 2.26-2003 Decorative Gas
Appliances for Installation in Solid Fuel Burning Fireplaces by OMNI Test Laboratories.
MPF18VNA AND MPF24VNA
• Variable Rating: 36,000/53,000 Btu/hr
• Gas Type: Natural Gas Only
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 10.5", Minimum* - 5.0"
* For purpose of input adjustment
Purchase these appliances from your local dealer.
If they can not supply these accessories, call DESA
at 1-866-672-6040 for referral information. You
can also write to the address listed on the back
page of this manual.
EQUIPMENT SHUTOFF VALVE
GA5010
Equipment shutoff valve with 1/8" NPT tap. Fits
1/2" pipe.
FIREPLACE HOOD
Black - GA6050
Brass - GA6052
Antique Brass - GA6053
Helps deflect heat away from mantel or wall above
fireplace. Fits opening 28" to 48" wide.
DAMPER CLAMP - GA6080
(Not Shown)
Permanently opens chimney flue damper for
vented operation.
LAVA ROCK - GA6060
(Not Shown)
Order when additional rock is desired (1.8 lb. bag)
114925-01C
SPECIFICATIONS
MPF18VPA AND MPF24VPA
• Variable Rating: 35,000/45,000 Btu/hr
• Gas Type: Propane/LP Gas Only
• Ignition: Piezo
• Manifold Pressure: 10" W.C.
• Inlet Gas Pressure (in. of water):
* For purpose of input adjustment

ACCESSORIES

RECEIVER AND HAND-HELD
REMOTE CONTROL KIT - HRC100
Allows the gas log heater to be turned on and off
using a hand-held remote control. A wall-mount
docking station is included.
CLEANING KIT - GCK
(Not Shown)
Your vented gas appliance requires regular cleaning
and maintenance to prevent performance problems.
This kit gives you the tools and instructions to make
it easy to clean all critical areas of your appliance.
When Using Remote
To Remote
Receiver
www.desatech.com
Maximum - 14", Minimum* - 11"

WIRING DIAGRAM

Thermopile
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Firewerks mpf18vpaFirewerks mpf24vpaFirewerks mpf24vna

Table of Contents