OPERATING HEATER (MANUALLY-CONTROLLED MODELS)
16
To Turn Off Gas to Appliance
Manual Lighting Procedure
OPERATING HEATER (THERMOSTAT MODELS)
For Your Safety Read Before Lighting
Lighting Instructions
OPERATING HEATER
Continued
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. Remove control cover log (see Figure 23, page 15).
2. Press in and turn control knob clockwise
HI position.
3. Turn the control knob clockwise
position.
4. Press in control knob and turn clockwise
OFF position.
5. Replace control cover log (see Figure 23, page 15).
Shutting Off Burners Only (pilot stays lit)
1. Remove control cover log (see Figure 23, page 15).
2. Turn the control knob clockwise
3. Press in and turn control knob clockwise
PILOT position.
4. Replace control cover log (see Figure 23, page 15).
MANUAL LIGHTING
PROCEDURE
1.
Follow steps 1 through 6 under Lighting Instructions, page 15.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob. Now follow
steps 9 and 10, page 15, column 2.
THERMOSTAT MODELS
FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
to the
Clockwise
to the PILOT
Clockwise
to the
Clockwise
to the HI position.
Clockwise
to the
Clockwise
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by
hand, don't try to repair it, call a qualified service techni-
cian or gas supplier. Force or attempted repair may result
in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
LIGHTING
INSTRUCTIONS
WARNING:
• If fireplace has glass doors, never operate this
heater with glass doors closed. If you operate
heater with doors closed, heat buildup inside fire-
place will cause glass to burst. Make sure there are
no obstructions across opening of fireplace.
• You must operate this heater with a fireplace screen
in place. Make sure fireplace screen is closed
before running heater.
NOTICE: During initial operation of new heater, burn-
ing logs will give off a paper-burning smell. Orange
flame will also be present. Open damper or window to
vent smell. This will only last a few hours.
Note: Home owners generally prefer to operate their heater
with the chimney damper closed. This will put all the heat into
the room. However, there may be times you will desire the full
flames of the HI heat setting but will find the heat output
excessive. You can open the chimney damper (if you have one)
fully or partially to release some of the heat.
WARNING: Damper handle will be hot if heater
has been running.