INSTALLATION
Continued
NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one
of the following:
• operate the logs only with the
flue damper open
• raise the mantel to an accept-
able height
• remove the mantel
12"
10"
8"
6"
2
1 /2
"
Minimum
Noncombustible
Material
Hood
(GA6050,
(GA6050,
GA6052)
GA6052 and
GA605)
Figure 7 - Minimum Mantel Clearances
When Using Hood
FLOOR CLEARANCES
A. If installing appliance on the floor level, you
must maintain the minimum distance of 14"
to combustibles (see Figure 8).
B. If combustible materials are less than 14" to
the fireplace, you must install appliance at
least 5" above the combustible flooring (see
Figure 9).
Figure 8 - Minimum Fireplace Clearances
if Installed at Floor Level
119421-01A
Mantel Shelf
All minimum
distances are
in inches
8"
12"
15"
18"
20"
Min.
Distances to
Underside of
Mantel
Combustible
Material
14"
Min.
Noncombustible
Material
www.desatech.com
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
INSTALLING DAMpER CLAMp
ACCESSORY FOR VENTED
OpERATION
Note: When used as a vented heater, appliance
must be installed only in a solid-fuel burning
Underside
of Mantel
fireplace with a working flue and constructed of
Shelf
noncombustible material.
If your heater is a manually-controlled model, you
may use this heater as a vented product. There
are three reasons for operating your heater in the
Log Set
vented mode.
18", 24",
30" Models
1. The fireplace does not meet the clearance
to combustibles requirements for vent-free
Top of
operation.
Fireplace
Opening
2. State or local codes do not permit vent-free
operation.
3. You prefer vented operation.
If reasons number 1 or 2 above apply to you, you
must permanently open chimney flue damper. You
must install the damper clamp accessory (to order,
see Accessories, page 25). This will insure vented
operation (see Figure 10). The damper clamp will
keep damper open. Installation instructions are
included with clamp accessory.
Damper
Clamp
Masonry
Fireplace
Figure 10 - Attaching Damper Clamp
Hearth
5"
Min.
Damper
Damper
Clamp
Damper
Manufactured
Combustible
Material
Damper
Fireplace
11