LOCAL CODES

Install and use furnace with care. Follow all
local codes. In the absence of local codes, use
the latest edition of the following:
• National Fuel Gas Code ANS Z223.1,
also known as NFPA 54 * (USA)
• National Electric Code ANS/NFPA 70*
• CAN/CGA-B149[.1 or .2] Installation
Codes** (Canada).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
**Available from:
Standards Council of Canada
350 Sparks Street
Ottawa, Ontario K1R 7S8
This furnace must be grounded when in-
stalled. Follow all local codes. In the ab-
sence of local codes, refer to the National
Electrical Code ANS/NFPA No. 70 (U.S.A.)
or CSA C22.1 Canadian Electrical Code,
Part I (Canada).
The installation must conform with local
codes, in the absence of local codes, with the
National Fuel Gas Code, ANS Z223.1/Ca-
nadian Installation Code, CAN/CGA B149.
When installing furnace in a manufactured
(mobile) home, follow the Manufactured
Home Construction and Safety Standard,
Title 24CFR, Part 3280 (formerly the Fed-
eral Standard for Mobile Home Construc-
tion and Safety, Title 24, part 280; 1975).
When such a standard is not applicable,
follow the Standard for Manufactured Home
Installations, 1982 (Manufactured Home
Sites, Communities, and Set-Ups), ANS
A225.1/NFPA 501A.
In Canada, install furnace in accordance with
Standard CSA Z240.4 - Gas Equipped Recre-
ational Vehicles and Mobile Housing and
any applicable local codes and regulations.
Appliance input ratings are based on sea
level operation and need not be changed for
operation up to 2,000 feet elevation. For
operation at elevations above 2,000 feet,
manufactured to specified deration condi-
tions for Canada and the United States.
201835
UNPACKING
1. Remove furnace from carton.
2. Remove all protective packaging ap-
plied to furnace for shipment.
3.
Remove the following items from carton:
• Hardware package containing four
large screws, two small screws, and
thermostat mounting plate
• Hardware package (thermostat and
two screws)
• Equipment shutoff valve
If any of these items are missing,
promptly inform dealer where you
bought furnace.
4.
Check furnace for any shipping damage.
If furnace is damaged, promptly inform
dealer where you bought furnace.

SPECIFICATIONS

*Rated Heating Input (BTU/Hr)
Thermal Output Capacity
(average loss calculation)
Type Gas
Ignition
Operating Amps
Volts/Cycles
Main Burner
Pressure Regulator Setting
Inlet Connection
Inlet Gas Pressure (in. of water)*
Maximum
Minimum
Dimensions, Inches (H x W x D)
Furnace
Weight (pounds)
Furnace
Shipping
* For purposes of input adjustment.
3
OWNER'S MANUAL
PRODUCT
FEATURES
HOT SURFACE IGNITOR
This furnace has an electronic ignitor. There
is no standing pilot. No matches or batteries
are required.
THERMOSTATIC HEAT
CONTROL
The thermostat is temperature sensitive. It
automatically turns the furnace on and off.
This results in the greatest heating comfort.
This can also result in lower gas bills.
LIMIT SWITCH
The limit switch shuts off the gas to the main
burner if the furnace becomes too hot to
operate safely.
DNV25NB
25,000
18,750 Btu/Hr
Natural Only
Hot Surface Ignitor
1.5
120/60
1
3.5" W.C.
3/8 NPT
7"
5"
3
1
5
15
/
x 16
/
x 23
/
32
8
53
65
DNV40NB
40,000
30,000 Btu/Hr
Natural Only
Hot Surface Ignitor
2
120/60
2
3.5" W.C.
3/8 NPT
7"
5"
3
3
5
15
/
x 21
/
x 23
/
8
32
4
8
71
98