Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Samsung Manuals
Air Conditioner
AR24RXFP Series
Installation manual
Samsung AR24RXFP Series Installation Manual
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
page
of
27
Go
/
27
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Installation
Safety Information on Installation
Preparation
Step 1.1 Choosing the Installation Location
Step 1.2 Unpacking
Step 1.3 Checking and Preparing Accessories and Tools
Step 1.4 Drilling a Hole through the Wall
Indoor Unit Installation
Step 2.1 Connecting the Power and Communication Cables (Assembly Cable)
Step 2.2 Optional: Extending the Power Cable
Step 2.3 Installing and Connecting the Drain Hose
Step 2.4 Optional: Extending the Drain Hose
Step 2.5 Optional: Changing the Direction of the Drain Hose
Step 2.7 Shortening or Extending the Refrigerant Pipes (Assembly Pipe)
Step 2.8 Fixing the Installation Plate
Outdoor Unit Installation
Step 3.1 Fixing the Outdoor Unit in Place
Step 3.3 Evacuating the Air
Step 3.4 Adding Refrigerant
Step 3.5 Important Information: Regulation Regarding the Refrigerant Used
Installation Inspection
Step 4.1 Performing the Gas Leak Tests
Step 4.2 Running the Smart Install Mode
Step 4.3 Performing Final Check and Trial Operation
Maintenane Procedures
Sub PCB Installation(Optional)
Advertisement
Quick Links
1
Table of Contents
2
Step 1.1 Choosing the Installation Location
3
Step 2.1 Connecting the Power and Communication Cables (Assembly Cable)
4
Maintenane Procedures
Download this manual
Air conditioner
Installation manual
AR**RXFP***
• Thank you for purchasing this Samsung air conditioner.
• Before operating this unit, please read this user manual carefully and retain it for future reference.
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the AR24RXFP Series and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Samsung AR24RXFP Series
Air Conditioner Samsung AR18HSFNBWKNEU Service Manual
Split-type air conditioner (133 pages)
Air Conditioner Samsung AR09HSFSHWKNCV Service Manual
Indoor / outdoor unit (149 pages)
Air Conditioner Samsung AR09HSFSJWKN User & Installation Manual
(63 pages)
Air Conditioner Samsung AR09HCF Series User & Installation Manual
(56 pages)
Air Conditioner Samsung AR09KSWSJWKNCV Service Manual
(134 pages)
Air Conditioner Samsung AR12JSALBWKNCV Service Manual
(79 pages)
Air Conditioner Samsung AR24RXWXCWKNEU Service Manual
Indoor/outdoor units (128 pages)
Air Conditioner Samsung AR09RXPXBWKNEU Service Manual
Indoor/outdoor units (128 pages)
Air Conditioner Samsung AR TSFY WKNCV Series Service Manual
Indoor/outdoor unit (108 pages)
Air Conditioner Samsung AR09TXHQASINEU User's Manual & Installation Manual
(240 pages)
Air Conditioner Samsung AR09TXHQBWKNEU User Manual
(240 pages)
Air Conditioner Samsung AR09RXFPEWQNEU Service Manual
(112 pages)
Air Conditioner Samsung AR07TSFABWKN Service Manual
Multi air conditioner (109 pages)
Air Conditioner Samsung AR24BXHQASINUA User Manual
(50 pages)
Air Conditioner Samsung AR07CSDAFWKN Service Manual
Multi air conditioner (141 pages)
Air Conditioner Samsung AR07DXDAFWKN Service Manual
Multi air conditioner (220 pages)
Summarization of Contents
Safety and General Information
General Installation Information
Read manual carefully before installation and keep for future reference. Handle with care.
Product Installation Safety Guidelines
Crucial safety guidelines for installation, handling damaged products, and performing functional tests.
Installation Guides and Preparation
Seaside Installation Guide
Specific instructions for installing air conditioners near the sea to prevent corrosion and ensure proper function.
Outdoor Unit Installation Requirements
Guidelines and restrictions for installing the outdoor unit, including environmental and safety considerations.
Choosing the Indoor Unit Installation Location
Guidance on selecting an appropriate installation location for the indoor unit, considering clearances and pipe routing.
Unpacking the Indoor Unit
Procedure for safely unpacking the indoor unit from its packaging.
Indoor Unit Installation Steps
Drilling Wall Holes for Piping
Instructions on drilling the correct size hole in the wall for pipe bundle passage, ensuring proper slant.
Bundling Pipes, Cables, and Drain Hose
Steps for insulating and taping refrigerant pipes, power cables, and drain hose for protection and condensation prevention.
Connecting Power and Communication Cables
Detailed steps for connecting power and communication cables to the indoor unit, including wire specifications.
Extending the Power Cable
Procedure for safely extending the power cable using connection sleeves and contraction tubes.
Installing and Connecting the Drain Hose
Instructions for installing the drain hose and testing its drainage functionality.
Extending the Drain Hose
Guide on how to extend the drain hose using an extension hose and appropriate insulation.
Changing Drain Hose Direction
Steps to change the direction of the drain hose for proper water flow and drainage.
Connecting Refrigerant Pipes
Procedure for connecting indoor and outdoor unit refrigerant pipes using flare connections, specifying pipe types.
Modifying Refrigerant Pipe Length
Instructions for shortening or extending refrigerant pipes, including torque specifications and bending radius.
Fixing the Installation Plate
Guidelines for securely fixing the indoor unit's installation plate to walls, window frames, or gypsum boards.
Outdoor Unit Installation Steps
Fixing the Outdoor Unit in Place
Instructions for placing and securing the outdoor unit on its support, ensuring stability and proper air flow.
Connecting Outdoor Unit Cables and Pipes
Steps for connecting power, communication cables, and refrigerant pipes to the outdoor unit.
Evacuating Air from the System
Procedure for removing air and moisture from the refrigerant circuit using a vacuum pump to ensure system integrity.
Adding Refrigerant (R-32)
Guidelines for safely adding R-32 refrigerant, including precautions and pipe length considerations.
Refrigerant Regulations and Safety
Information on fluorinated greenhouse gases (R-32) and relevant regulations for handling and venting.
Installation Inspection and Maintenance
Performing Gas Leak Tests
Detailed steps for testing refrigerant pipe connections for leaks using soap lather or liquid.
Running Smart Install Mode
Instructions on how to initiate and use the Smart Install mode for automated system setup and checks.
Final Checks and Trial Operation
Steps to perform final checks and conduct a trial operation to ensure the air conditioner functions correctly.
Gas Leak Tests for Repair
Procedure for performing gas leak tests during repair of the refrigerant circuit, emphasizing safety and proper flushing.
Decommissioning Procedures
Requirements for safely decommissioning the unit, including refrigerant recovery and electrical isolation.
Optional Sub PCB Installation
Sub PCB Installation Steps
Instructions for installing the optional Sub PCB, typically for multi-system control.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the AR24RXFP Series and is the answer not in the manual?
Questions and answers