Correct use Linear Units LRE 8 D10 80x80 KGT and LRE 8 D14 80x80 KGT with controller ▪You are appropriately qualified, and motor are both a partly completed machine as defined in the Machinery ▪You are authorised to do so by your company,...
Operating parameters Linear Units LRE 8 D10 80x80 KGT and LRE 8 D14 80x80 KGT are generally constructed from Line 8 profiles that have been cut to size and various assem- blies. Before starting assembly work, it is important to check that all parts are present.
Page 5
Linear Unit LRE 8 D10 80x80 KGT 20x5 Maximum stroke H 2687 mm Safety clearance S 76.5 Basic mass (when stroke length = 0 mm) m Mass per mm of stroke m 12.8 g/mm Total mass m = + H * m Repeatability 0.05...
Preparation Drive, e.g.: Ball Screw Unit 20x20 or Ball Screw Unit 20x5 Support profile, e.g.: Profile 8 80x80 Guide, Roller guide 8 D10/D14 Fundamentally, a Linear Unit converts a rotary motion into a translational These components are picked for assembly and assembled in part or in full, motion.
Shaft-Clamp Profile and Shaft D14: There are various methods for assembling support profile, Shaft-Clamp Profile and Shaft. To make assembly easier, apply a film of oil or grease to the outer surfaces of the Shaft-Clamp Profile that come into contact with the support profile before pressing it into the groove.
The collet mechanism must be held in the floating bearing block for this purpose (see photo). It is advisable to use a fixture made of item profiles to help with this procedure. This fixture can be used to secure the bearing block and check that the screw is being clamped centrically in the collet mechanism.
Tensioning the screw collet mechanism, fixed bearing end Follow the same procedure you used for the floating bearing end to install the collet mechanism on the fixed bearing end. To do this, secure the preassem- bled fixed bearing block to the fixture and introduce the screw vertically. Ensure the centre ring for the fixed bearing end is fitted before the collet mechanism is fastened in place.
Adjust the yoke adapter at the preassembled fixed bearing end. To do this, move the yoke adapter as far as it will go towards the fixed bearing end (by turning the screw with a cranked handle or similar). Fit the floating bearing end bearing block and centre ring over the floating bearing end collet mechanism and fix it in place temporarily, so as to limit the effects of any sagging in the screw.
Application options Ø10 Connecting the yoke adapter to the LRF carriage Place the carriage of the linear guide onto the profile and slide it over the yoke adapter. Use the two grub screws (DIN 913-M5x5) to make height and angle adjustments to the yoke adapter.
Installing the bearing block, floating bearing end Until now, the bearing block at the floating bearing end has only been fixed in place temporarily. Now loosen the relevant screws so that the bearing block can move within the range permitted by the centre ring. Now move the carriage to the floating bearing end.
Connecting Drive Set KGT D40/D15 - 0.0.667.76 Drive Set KGT D40/D15 has been optimised for item Linear Units with a Ball Screw Unit. It connects them with a motor. This is made possible by an Adapt- er Plate that can be machined to suit any requirements. The central coupling bore can also be enlarged to match the drive shaft of the motor.
Page 14
Drive Set KGT D40/D15 SE 60 (0.0.672.78) and Drive Set KGT D40/D15 The drive shaft transfers drive torque without backlash. To ensure this SE 80 (0.0.672.77) are used solely to connect item Motors to Linear Unit functionality, position centre ring ZR1 between the bearing block and LRE 8 D10/D14 80x80 KGT.
Page 15
Units from item are automatically fitted with a Slide Stop that can be moved for the system. Thanks to its special shape, the Slide Stop can be used with to a different position or removed entirely, as required.
Page 16
Linear Unit LRE 8 D14 80x80 KGT 20x5 L = Gesamtlänge in Abhängigkeit von Hub H S = Sicherheitsabstand L=H+400 L =H+313 Linear Unit LRE 8 D10 80x80 KGT 20x20 L = Gesamtlänge in Abhängigkeit von Hub H S = Sicherheitsabstand L=H+400 L =H+313...
Synthetic lubrication oil ISO VG 460, e.g. item Track Oil for Linear Guides subsequently get shorter (approx. every 200 to 300 operating hours). A spray- (0.0.612.75).