GENERATORI G2200 G4000 G5500 G6000E IT DEES RU SAFETY MESSAGES Your safety and the safety of others are very important. We have provided important safety messages in this manual and on the generator. Please read these messages carefully. A safety message alerts you to potential hazards that could hurt you or others.
GENERATORI G2200 G4000 G5500 G6000E IT DEES RU 2.COMPONENT 3.CONTROL IDENTIFICATION GENERATOR SwITCh G2200 64000 G5500 DC TERMINAL VOLTAGE POSTS GENERATOR METER SWITCH CIRCUIT FUEL BREAKER VALVE GENERATOR CHOKE SWITCH LEVER STARTER GRIP AIR CLEANER Per avviare il motore, tirare leggermente la maniglia di RECOIL avviamento finché...
GENERATORI G2200 G4000 G5500 G6000E IT DEES RU ChOkE lEvER OIl AlERT SYSTEM The choke lever is used to provide an enriched fuel mixture The oil alert system is especially designed to prevent engine when starting a cold engine. damage caused by an insufficient amount of oil in the Slowly put the choke lever to “OPEN”...
Page 7
GENERATORI G2200 G4000 G5500 G6000E IT DEES RU GENERATOR GROuNDING starting power, and connect others one by one, each with a lower starting power than the preceding one, To prevent electrical shock or misuse from faulty appliances, finally, connect the one with the lowest starting power. the generator should be grounded with an insulated lead.
GENERATORI G2200 G4000 G5500 G6000E IT DEES RU DC CuRRENT WARNING If a carburetor for high altitude operation is installed • DC Terminals onto an engine suitable to a lower altitude, the lean air fuel mixture will cause lower engine output power, over The DC terminals are used to provide power supply for heating and serious damage.
GENERATORI G2200 G4000 G5500 G6000E IT DEES RU 6. STARTING THE ENGINE FuEl 1) Check the fuel level gauge. RECOIl STARTER 2) Replenish the tank if the fuel level is low. Do not let oil level rise above the shoulder of the fuel strainer. (1) Remove all the loads from the output side.
GENERATORI G2200 G4000 G5500 G6000E IT DEES RU 8. MAINTENANCE Always follow the inspection and maintenance recommendations and schedules in this owner’s manual. Good maintenance is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. ENGINE OIl ChANGE Drain the oil while the engine is warm to ensure complete WARNING...
Page 11
GENERATORI G2200 G4000 G5500 G6000E IT DEES RU (3) Reinstall the O-ring, and strainer and screw back the WARNING sediment cup. Never run the generator without the air cleaner. If not, (4) Turn the fuel valve ON and check for leaks. rapid engine wear will result.
GENERATORI G2200 G4000 G5500 G6000E IT DEES RU 10. TROUBLESHOOTING If it need be stored for a long time, be sure the storage area is clean and dry. ENGINE uNAblE TO START: (1) Drain the fuel in the fuel tank out, clean strainer, o-ring and sediment, then refit them well.
Page 13
GENERATORI G2200 G4000 G5500 G6000E IT DEES RU bATTERY FUEL TANK CAP WARNING FUEL METER FUEL Don’t connect the battery positive and negative TANK poles reversely (pay attention to leads mark). When connecting, first connect the positive poles, then negative poles. When disconnecting, first disconnect the negative pole, then positive poles, if not, serious damage may be caused to the generator set and battery.
GENERATORI G2200 G4000 G5500 G6000E IT DEES RU 13. SPECIFICATIONS (5) Turn the GENERATOR switch to electric starting position. (6) After starting engine, immediately release generator switch and generator switch can automatically return to open position. Item G2200 G4000 G5500 G6000E (7) Turn the choke lever to the “OPEN”...