Siemens SIPROTEC 7ST63 Manual

Siemens SIPROTEC 7ST63 Manual

Input/output unit, bay control unit, communication module, profibus-dp communication profile
Table of Contents

Advertisement

SIPROTEC
Protection devices
7SA522, 7SA6
7SD5, 7SD610
7SJ61...7SJ64
7ST622, 7ST61, 7ST63
7UM61, 7UM62
7UT612, 7UT613, 7UT63
7VE61, 7VE63
7VK61
Input/Output unit
6MD63
Bay control unit
6MD663/6MD664
Communication module
PROFIBUS-DP
Communication profile
Revision 4.2
Edition: April 2005
C53000-L1840-B001-03
Preface
Table of contents
PROFIBUS Communication modules
Parameters and properties
Data type definitions
PROFIBUS-DP - Parameterization in DIGSI
Technical data
Index
1
2
3
4
5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIPROTEC 7ST63 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Preface
Purpose of this Manual
Explains the manual's objective, scope, and the topics covered.
PROFIBUS Communication Modules
Communication Module Types and Hardware Revisions
Details on available PROFIBUS communication modules, their hardware revisions, and compatibility.
Display of Module-Specific Information
Explains how to access and interpret module-specific data on the SIPROTEC device.
Parameters and Properties
Bus Specific Parameters
Defines settings for serial communication between PROFIBUS-DP master and slave.
PROFIBUS-DP Settings
Covers slave address and PNO identification number for PROFIBUS-DP configuration.
Configuration of the Fibre-Optical Interface
Details settings for operating mode, redundancy, and network size for fibre-optical modules.
Event List Settings
Configures the number of entries for the event list.
PROFIBUS-DP Configuration Data
Provides data required in the PROFIBUS-DP master for device parameterization.
Execution of Switching Operations via PROFIBUS-DP
Explains how to execute switching operations using PROFIBUS-DP.
Command Output Modes
Explains double commands, single commands, continuous, and pulse output modes.
Transformer Tap Change Commands
Details transformer tap change commands via PROFIBUS-DP.
Behaviour Under Special Operating Conditions
Describes device behavior during special operating conditions.
Response in Case of Disturbed Communication
Details system response to communication interruptions with the PROFIBUS-DP master.
Signalling of Line-breaks in Redundant Fibre-Optical Ring
Explains how line-breaks are signaled in redundant fibre-optical ring topologies.
Annunciations to the PROFIBUS-DP Master
Describes how the SIPROTEC device sends annunciations to the PROFIBUS-DP master.
Event List via PROFIBUS-DP (Sequence of Events Recorder)
Functionality for recording and retrieving events via PROFIBUS-DP.
Properties of the Event List
Details the characteristics and behavior of the event list.
Structure of a PROFIBUS-DP Telegram with Event List
Describes the structure of PROFIBUS-DP telegrams for event list retrieval.
Handshake Mechanism
Explains the handshake mechanism for event list data exchange.
Data Type Definitions
Single-point Indication (SP, Input) Data Type
Defines the data type for single-point indications transmitted from the device.
Single Command (SC, Output) Data Type
Defines the data type for single commands sent to the device.
Double-point Indication/Command Data Types
Defines data types for double-point indications and double commands.
Measured Value (Signed Integer) Data Type
Defines the data type for measured values transmitted as signed integers.
Measured Value (Float) Data Type
Defines the data type for measured values transmitted in floating-point format.
Metered Measurand (Unsigned Long) Data Type
Defines the data type for metered measurands transmitted as unsigned long.
Transformer Tap Change Command (TC) Data Type
Defines the data type for transformer tap change commands.
Transformer Tap Position Indication (TM) Data Type
Defines the data type for transformer tap position indications.
Message Block for Event List Data Type
Defines the complex data type for event list entries.
PROFIBUS-DP - Parameterization in DIGSI
Interface Selection and Mapping Files
Covers selecting the interface and mapping files for PROFIBUS-DP parameterization.
Standard Mappings 3-1 to 3-n
Available standard mappings for pre-allocation of SIPROTEC data objects.
Interface Selection and Mapping in DIGSI 4.21
Details interface and mapping selection process using DIGSI version 4.21.
Interface Selection and Mapping in DIGSI 4.3+
Details interface and mapping selection process using DIGSI version 4.3 and higher.
Customization of the Allocations
Explains how to customize data object routing in the DIGSI Configuration matrix.
Scaling of Measured Values
Describes the process of converting measured values for PROFIBUS-DP transmission.
Time Synchronization
Details using time synchronization messages via PROFIBUS System Management Service.
Parameterization in DIGSI
Configuring time synchronization evaluation in SIPROTEC devices.
Using SFC14 and SFC15 in STEP7
Explains using system functions SFC14 and SFC15 for data transmission with S7-CPU.
Technical Data
Technical Data: PSE Module Connection
Provides technical specifications for the PROFIBUS RS485 interface (PSE module).
Technical Data: PSO Module Connection
Provides technical specifications for the fibre-optical interface (PSO module).

Table of Contents

Save PDF