Delfield 6176XL-S Service, Installation And Care Manual

Delfield 6176XL-S Service, Installation And Care Manual

Reach ins
Hide thumbs Also See for 6176XL-S:

Advertisement

6000XL & 6100XL Series Reach Ins
Service, Installation and Care Manual
Please read this manual completely before attempting to install or operate this equipment! Notify carrier of
damage! Inspect all components immediately. See page 2.
Refrigerators and Freezers

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6176XL-S and is the answer not in the manual?

Questions and answers

Summarization of Contents

Installation
Installation Location Guidelines
Proper placement for air circulation and floor support to ensure optimal refrigeration.
Unit Leveling Procedures
Ensuring the unit is level for proper door alignment, strain reduction, and product stability.
Unit Stabilization and Mobility
Securing units on casters and precautions for laying the unit on its side.
Electrical Connection Requirements
Connecting the unit to the correct power source based on amperage data and codes.
Installation Warranty Note
Improper installation procedures may void unit repairs and standard warranties.
Operation
Temperature Control Settings
Adjusting the thermostat for refrigerators and freezers to set desired internal temperatures.
Refrigeration Cycle Explanation
How evaporator fans, door switches, and anti-sweat heaters function during the cooling cycle.
Freezer Defrost Cycle
Explanation of the automatic defrost process for freezers using heaters and timers.
Defrost Control Models
Details on Paragon 8145 and Air-O-Tronics defrost controls for different freezer models.
Setting Defrost Timer Time of Day
Instructions for setting the time on Paragon 8145 defrost timers for two and three door models.
One Door Freezer Defrost Operation
How to adjust defrost cycles for one-door models using dip switches.
Two/Three Door Freezer Defrost Operation
Setting defrost initiation times for two and three-door models using the Paragon 8145 timer.
Maintenance
Interior and Exterior Cleaning
Guidelines for cleaning the inside and outside surfaces using appropriate cleaning agents.
Condenser Coil Cleaning
Regular cleaning of the condenser coil to prevent overheating and compressor failure.
Stainless Steel Care and Cleaning
Proper methods for cleaning stainless steel to prevent rust and maintain its finish.
Maintenance Continued
Gasket Maintenance and Replacement
Cleaning and replacing door gaskets to ensure proper seals and prevent mold.
Door and Hinge Adjustment
Adjusting door hinges that may become loose over time due to heavy use.
Drain Maintenance and Troubleshooting
Ensuring drain lines are clear and connected to prevent water accumulation and overflow.
Defrost Timer Programming
Defrost Duration Settings
User control for defrost duration using dip switch settings.
Defrost Cycle Time Settings
User control for defrost cycle frequency using dip switch settings.
Defrost Programming Example
Illustrates defrost duration and cycle frequency settings.
Paragon 8145 Timer Adjustment
Instructions for setting the time of day on the Paragon 8145 defrost timer.
Standard Labor Guidelines
1-Hour Labor Replacement Guide
List of components that can be replaced within a 1-hour labor allowance.
2-Hour Labor Replacement Guide
List of components that can be replaced within a 2-hour labor allowance.
3-Hour Labor Replacement Guide
List of components that can be replaced within a 3-hour labor allowance.
4-Hour Labor Replacement Guide
List of components that can be replaced within a 4-hour labor allowance.
Refrigerant Reimbursement Rates
Maximum reimbursement rates for different types of refrigerants.
Limited Lifetime Warranty
Warranty Coverage Details
Specifies that the ABS interior liner is covered against manufacturing defects.
Delfield's Warranty Obligation
Delfield will ship OEM replacement parts or repair kits for covered ABS interior defects.
User's Warranty Responsibilities
User must follow manual for installation, cleaning, and maintenance to maintain warranty.
Warranty Claim Procedures
Steps for making claims, including returning defective parts and providing necessary information.
Warranty Exclusions
Lists conditions and actions that are not covered by the warranty.
Standard One Year Warranty
One Year Parts and Labor Warranty
Covers defects in material and workmanship for one year from shipment or installation date.
Warranty Exclusions and Limitations
Details conditions like misuse, neglect, alteration, or unauthorized repairs that void the warranty.
Product Spoilage and Installation Responsibility
States no claims for spoilage and contractor responsibility for building access.
Force Majeure and Liability Disclaimers
Disclaims liability for delays due to uncontrollable events and other specific items.
Warranty Disclaimer and Exclusive Remedies
Disclaims implied warranties and states exclusive remedies and liability limits.
Liability for Special or Consequential Damages
States Delfield is not liable for special, incidental, or consequential damages.
Voiding Warranty with Non-Approved Parts
Using modified or unauthorized parts voids the warranty; service agreements are an option.

Table of Contents

Save PDF