Advertisement

SITOP power supply
SITOP PSU8200/3800 3ph
Manual
SITOP PSU8200 24 V/20 A
6EP3436-8SB00-0AY0
SITOP PSU8200 24 V/40 A
6EP1437-3BA10
SITOP PSU8200 24 V/40 A
6EP3437-8SB00-0AY0
SITOP PSU8200 36 V/13 A
6EP3446-8SB10-0AY0
SITOP PSU8200 48 V/10 A
6EP3446-8SB00-0AY0
SITOP PSU8200 48 V/20 A
6EP3447-8SB00-0AY0
SITOP PSU3800 12 V/20 A
6EP3424-8UB00-0AY0
SITOP PSU3800 24 V/17 A
6EP3436-8UB00-0AY0
SITOP PSU3800 24 V/40 A
6EP3437-8UB00-0AY0
05.2018
C98130-A7638-A1-6-7629
___________________
Overview
___________________
Notes on safety
___________________
Description, device design,
dimension drawing
___________________
Mounting/removing
___________________
Mounting position, mounting
clearances
___________________
Installation
___________________
Technical data
___________________
Safety, approvals, EMC
___________________
Ambient conditions
___________________
Applications
___________________
Environment
___________________
Service & Support
1
2
3
4
5
6
7
8
9
10
11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SITOP PSU8200 48 V/10 A and is the answer not in the manual?

Questions and answers

Summarization of Contents

Notes on safety
General safety instructions
General safety instructions for handling electrical devices and preventing hazards.
Safety instructions for hazardous zones
Specific safety precautions for operating equipment in hazardous areas (ATEX).
Description, device design, dimension drawing
Device description
Overview of the SITOP PSU8200/3800 3ph power supply and its key features.
Connections and terminal designation
Details on input/output terminals, signaling and remote contacts, and wire specifications.
Potentiometer function
Explanation of the potentiometer for adjusting output voltage and related warnings.
Status displays and signaling
Description of LED indicators and signaling contacts for operating status.
Change-over switch functionality
Function of switches A and B for output characteristic selection.
Block diagram overview
Schematic representation of the internal functional blocks of the power supply.
Dimensions and weight
Physical dimensions and weight specifications for different SITOP models.
Mounting/removing
Device mounting and removal
Instructions for mounting and removing the SITOP PSU8200/3800 3ph in control cabinets.
Mounting position, mounting clearances
Standard mounting position guidelines
Recommended vertical mounting orientation for optimal cooling and clearance.
Other mounting positions and derating
Derating factors and considerations for non-standard mounting orientations.
Installation
Line-side connection procedure
Guidance on connecting the power supply to a 3-phase AC line supply.
Output-side connection procedure
Instructions for connecting loads to the DC output terminals.
Technical data
Input electrical specifications
Detailed data on input voltage, frequency, current, and protection requirements.
Output electrical specifications
Detailed data on output voltage, current, power, and response characteristics.
Efficiency and power loss data
Data on power efficiency and losses at various operating conditions.
Closed-loop control parameters
Parameters for dynamic line/load regulation and response times.
Protection and monitoring features
Information on overvoltage, current limitation, and short-circuit protection.
MTBF (Mean Time Between Failures)
Reliability data indicating the average time between failures for the devices.
Mechanical system specifications
Details on connection systems, dimensions, weight, and mounting types.
Available accessories
List of electrical and mechanical accessories for SITOP products.
Dimension drawing references
References to CAD data for product dimensions.
Safety, approvals, EMC
Electrical safety parameters
Electrical safety data including isolation, protection class, and leakage current.
Test voltage specifications
Electrical withstand voltage test specifications for type, production, and field tests.
Product certifications and approvals
Summary of certifications and approvals like CE, UL, ATEX, IECEx.
EMC compliance standards
EMC test standards for electrostatic discharge, fields, surges, and interference.
Ambient conditions
Environmental operating parameters
Operating temperature, storage, humidity, and mechanical stress specifications.
Applications
Parallel connection for power rating increase
Guidelines for connecting power supplies in parallel to increase total output power.
Parallel connection for redundancy
Methods for configuring power supplies in parallel for increased system availability.
Series connection for increased voltage
Procedure for connecting power supplies in series to achieve higher output voltages.
Output circuit overload protection
Strategies for protecting loads against overload and short circuits.
Protection against short-time voltage dips
Using buffer modules to maintain output voltage during brief supply interruptions.
Protecting against longer power failures
Solutions for buffering longer power failures using DC-UPS modules.
Battery charging application
Specific application for using SITOP PSU3800 for charging lead batteries.
Environment
Disposal and recycling guidelines
Instructions for proper disposal and recycling of the product and packaging.
Service & Support
Technical support and documentation access
Information on obtaining technical support, documentation, and selection tools.
Finding regional contact persons
How to find regional Siemens sales offices for product inquiries.

Table of Contents