Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Robur Manuals
Heater
G 100
Instructions for installation, use and maintenance manual
Robur G 100 Instructions For Installation, Use And Maintenance Manual
Gas unit heaters product line g series condensing and modulating gas fired unit heaters to heat medium large areas natural gas/lpg fired
Hide thumbs
1
2
3
Table Of Contents
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
page
of
64
Go
/
64
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Section1: GENERAL INFORMATION and TECHNICAL CHARACTERISTICS
General Warnings
Operation of the Unit
Constructive Characteristics
Technical Data
Dimensions of G Series Gas Fired Unit Heater
Section 2: END USER
Functions of Chronothermostat
Setting the Time and Day on the Chronothermostat
Setting the Comfort, Economy and Anti- Freezing Temperatures on the Chronothermostat
Programming of the Daily Set Point on the Chronothermostat
Selecting a Preset Daily Profile on the Chronothermostat
Selecting a Preset Weekly Profile on the Chronothermostat
Timed Functions of the Chronothermostat
Keyboard Block
Information Screen of the Chronothermostat
Selection Menu Window
Malfunction Warnings
Table of Icon Meanings on Chronothermostat Display
How to Use the Unit Heater
How to Use the Unit with the Chronothermostat
How to Use the Unit Without a Chronothermostat
Setting Field
End of Season
Section 3: PLUMBER INSTALLER
General Rules for Installation of the Appliance
Installation Sequence
Size and Installation of the Air Inlet / Exhaust Flue
Condensate Drainage
Section 4: ELECTRICAL INSTALLER
How to Connect the Heater to the Electrical System
How to Connect the Chronothermostat to the Heater
Unit Operation with External Consent
Remote Signalling of the Anomalies
Installation Wiring Diagram
Wiring Diagram for Multiple Heater with One Programmer
Section 5: ASSISTANCE and MAINTENANCE
Start up of the Unit
How to Regulate the Gas Valve
Conversion to Another Type of Gas
Maintenance
Advertisement
Quick Links
1
General Warnings
Download this manual
Installation, use and
maintenance manual
Gas unit heaters product line
G Series
Condensing and modulating Gas Fired Unit Heaters
to heat medium large areas
Natural gas/LPG fired
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the G 100 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Robur G 100
Heater Robur G 30 Instructions For Installation, Use And Maintenance Manual
Gas unit heaters product line g series condensing and modulating gas fired unit heaters to heat medium large areas natural gas/lpg fired (64 pages)
Heater Robur TS 2000 Installation, Use And Maintenance Manual
Individual natural gas/lpg natural draught gas-fired convectors (20 pages)
Heater Robur Supercromo D-LBR167 Installation, Use & Maintenance Manual
Independent gas-fired convectors with direct exchange to heat small and medium sized rooms, fired by natural gas/lpg (28 pages)
Heater Robur Supercromo Installation, Use And Maintenance Manual
Independent gas-fired convectors with direct exchange to heat small and medium sized rooms (28 pages)
Heater Robur 5001 Trouble-Shooting And Service Manual
Gas-fired wall heater (22 pages)
Heater Robur Next-R Installation, Use And Maintenance Manual
(60 pages)
Heater ROBUR TS2000 Series Installation, Use And Maintenance Manual
(20 pages)
Heater Robur AY00-119 Series Manual
(4 pages)
Heater Robur Next-R Instructions For Installation, Use And Maintenance Manual
Gas unit heaters for use in industrial and commercial installations (52 pages)
Heater Robur Calorio M 42M Installation, Use And Maintenance Manual
Independent direct exchange gas-fired convectors with automatic modulation to heat small and medium-sized rooms (36 pages)
Heater Robur Heaters Line F2 C Series Instructions For Installation, Use And Maintenance Manual
Gas fired unit heaters for heating medium-large areas natural gas/lpg fired (46 pages)
Summarization of Contents
Section 1: General Information & Technical Specs
General Warnings
Essential safety guidelines and precautions for the installation and use of the unit.
Unit Operation Overview
Explanation of how the gas fired unit heater operates, including burner ignition and fan control.
Constructive Characteristics
Details on the design features and components of the gas fired unit heaters.
Technical Data Specifications
Key technical specifications, performance data, and measurements for the G Series heaters.
Dimensions of G Series Gas Fired Unit Heaters
Physical dimensions and layout diagrams for the G Series gas fired unit heater models.
Section 2: End User Operations
Chronothermostat Functions
Overview of the buttons and their functions on the digital chronothermostat controller.
Setting Time and Day on Chronothermostat
Step-by-step instructions for setting the current time and day on the chronothermostat.
Setting Temperatures (Comfort, Economy, Anti-Freezing)
Guide to setting desired temperatures for comfort, economy, and frost protection modes.
Programming Daily Set Points
Procedure for programming daily temperature changes and operating schedules on the chronothermostat.
Selecting Preset Daily Profiles
Instructions for choosing pre-defined daily heating and cooling profiles for the chronothermostat.
Selecting Preset Weekly Profiles
Guide to selecting and applying pre-defined weekly heating and cooling schedules.
Chronothermostat Timed Functions
Explanation of timed operation modes: Forced Automatic, Timed Shut Down, and Timed Manual.
Forced Automatic Operation
How to activate temporary temperature adjustments outside the programmed schedule.
Timed Shut Down Mode (Vacation Program)
Instructions for setting a period of reduced operation or shutdown for vacation.
Timed Manual Operation (Party)
How to set a specific temperature for a limited duration, returning to automatic mode afterward.
Chronothermostat Keyboard Block
Enabling and disabling the keyboard lock feature to prevent unauthorized changes.
Chronothermostat Information Screen
Accessing and understanding various parameters displayed on the chronothermostat's information screen.
Selection Menu Window
Overview of parameters available for personalizing the unit's operating mode.
Malfunction Warnings
Identification and interpretation of error codes displayed on the chronothermostat.
Chronothermostat Display Icon Meanings
Reference guide to the icons displayed on the chronothermostat screen and their meanings.
How to Use the Unit Heater
General options for operating the gas fired unit heater with or without a chronothermostat.
Using the Unit with Chronothermostat
Detailed operating modes (heating/ventilation) when using the chronothermostat.
Automatic Modulating Functioning
Explanation of automatic heat output modulation with total or fixed ventilation.
Automatic Fix Functioning
How the unit operates with fixed heat output, controlled automatically by the chronothermostat.
Using the Unit Without Chronothermostat
Operating the unit in winter, summer, or renewable air modes without a chronothermostat.
Setting Field for Heat Input Adjustment
Adjusting the unit's maximum heat output percentage via the chronothermostat.
End of Season Procedures
Steps for properly shutting down the appliance at the end of the heating season.
Section 3: Plumber Installation Guide
General Rules for Appliance Installation
Essential guidelines and regulations for the safe and correct installation of the unit.
Installation Sequence Steps
The recommended order of operations for installing the gas fired unit heater.
Air Inlet and Exhaust Flue Installation
Guidance on sizing and installing air intake and exhaust flue systems for various configurations.
Sample Calculation for Flue System
An example calculation demonstrating how to determine pressure loss for air/flue ducting.
Condensate Drainage System
Instructions for connecting and maintaining the condensate drainage kit and piping.
Section 4: Electrical Installer Guide
Connecting Heater to Electrical System
Procedure for safely connecting the unit to the main electrical supply.
Connecting Chronothermostat to Heater
Instructions for wiring the chronothermostat to the unit's control board.
Unit Operation with External Consent
How to integrate external controls for unit operation in winter or summer modes.
Remote Signalling of Anomalies
Methods for remotely monitoring unit status and receiving anomaly notifications.
Installation Wiring Diagrams
Diagrams illustrating the electrical connections for G series units, including single and multiple units.
Wiring Diagram for Multiple Heaters
Specific wiring diagram for controlling multiple heaters with a single programmer.
Section 5: Assistance & Maintenance
Unit Start-Up Procedure
Steps for initial unit startup, verification of installation data, and correct functioning.
Regulating the Gas Valve
Procedure for adjusting the gas valve settings to ensure correct operation and performance.
Conversion to Different Gas Type
Instructions for converting the unit to operate with different types of gas, including nozzle replacement.
Routine Maintenance
Recommendations for regular cleaning and checks to ensure optimal performance and safety.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the G 100 and is the answer not in the manual?
Questions and answers