Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Qualitrol Manuals
Measuring Instruments
AKM 345 Gen2
Instruction manual
Qualitrol AKM 345 Gen2 Instruction Manual
Capillary based oil thermometer
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
page
of
32
Go
/
32
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
1 General
2 Installation
3 Calibration Check
4 Switch Setting
Optional) Adjustable Switch Differential Setting Instructions
Figure 1 - Switch Setting Scale
5 Technical Data - Matching Resistance TD50/TD76
Figure 2 - TD Adjusting Schematic
Instructions for Adjusting Matching Resistance
Figure 3 - Temperature Gradient Graph
Temperature Gradient Graph for WTI with External 1A and 5A Matching Unit
Figure 4 - Guideline for Adjustment of Heating Current
Wiring the AKM345 Double Gradient Option
Background
Wiring Recommendations
Using the 5 Amp Internal CT Option
Figure 4.1 - Guideline for Wiring Double Gradient Option
Setting the Matching Resistance
Method a
Method B
Figure 4.2 - TD50 / 5 Amp Wiring Example
6 Mounting Styles and Dimensions
Seismic Mount
Universal Mount
Figure 5 - Siesmic Mount
Figure 6 - Universal Mount
Anti-Vibration (Standard) Mount
Figure 7 - Anti-Vibration (Standard) Mount
7 Front Cover Removal
Figure 8 - Cover Hinge Side View
Figure 9 - Front Cover Removal
8 Contact Rating / Breaking Capacity
Figure 10 - Switch Selection
9 Terminal Block Arrangements
Figure 11 - 2 to 4 Switches W/Optional Heater and Remotes
Figure 11.1 - 2 to 4 Switches W/Optional Heater and Remotes
Figure 11.2 - 2 to 4 Switches W/Optional Heater and Remotes
Figure 12 - 5 to 6 Switches Only
Figure 13 - 5 to 6 Switches W/Optional Heater and Remotes
10 Pocket/Well Installation
Figure 14 - Pocket/Well Installation
11 Probe Types
12 Maintenance
Protection Class IP 65
Mountings with Rubber Dampers - Seismic Type and Universal Type
13 Gen2 with Transmitter
Technical Data
Installation Instructions
Figure 15 - 4-20Ma Suggested Wiring TD111
Figure 15.1 - 0-1Ma Suggested Wiring TD119-1
Figure 15.2 - 0-5Ma Suggested Wiring TD119-2
Figure 15.3 - 0-10Ma Suggested Wiring TD119-3
Figure 15.4 - 0-20Ma Suggested Wiring TD119-4
Figure 15.5 – 4-20Ma & 0-5V DC Suggested Wiring TD119-5
Figure 15.6 – 4-20Ma & 0-10V DC Suggested Wiring TD119-5
Figure 15.7 – Suggested Wiring TD66 CU10/PT100
Advertisement
Quick Links
1
General
2
Calibration Check
3
Installation
4
Technical Data - Matching Resistance Td50/Td76
5
Figure 15 - 4-20Ma Suggested Wiring Td111
Download this manual
Instruction Manual
AKM 345 Gen2
Oil Temperature Indicator AKM OTI Type 34
Winding Temperature Indicator AKM WTI Type 35
Document ID: IST-103-1-EN
www.qualitrolcorp.com
(IST-103-1-EN)
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the AKM 345 Gen2 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Qualitrol AKM 345 Gen2
Measuring Instruments Qualitrol AKM OTIWTI Instruction Manual
Capillary based oil thermometer (32 pages)
Measuring Instruments Qualitrol SERVERON TM1 Installation Manual
On-line transformer monitor (21 pages)
Measuring Instruments Qualitrol 505ITM Series Instructions Manual
Intelligent transformer monitor (117 pages)
Measuring Instruments Qualitrol INFORMA PMD-A User Manual
Data acquisition unit (248 pages)
Measuring Instruments Qualitrol OTIWTI AKM345 GEN3 Instruction Manual
Winding temperature indicator (34 pages)
Measuring Instruments Qualitrol 509-200 Operation Manual
Electronic cooling monitor for liquid-filled transformers (36 pages)
Measuring Instruments Qualitrol AKM345 GEN3 OTIWTI Quick Start Manual
Oil and winding temperature indicators (10 pages)
Summarization of Contents
General
Installation
Calibration Check
Switch Setting
(Optional) Adjustable Switch Differential Setting Instructions
Instructions for adjusting the differential setting of adjustable switches on the AKM345.
Technical Data – Matching Resistance TD50/TD76
Instructions for Adjusting Matching Resistance
Guide to correctly set the matching resistance for the TD50/TD76, using a graph.
Temperature Gradient Graph for WTI with External 1A and 5A Matching Unit
Graph illustrating temperature gradient for WTI with external 1A/5A matching units.
Wiring the AKM345 Double Gradient Option
Details on wiring the Double Gradient option for two separate winding simulations.
Using the 5 Amp Internal CT Option
Guidance on utilizing the internal 5 Amp Current Transformer option.
Setting the Matching Resistance
Two methods (A & B) for setting the matching resistance based on accuracy needs.
Mounting Styles and Dimensions
Seismic Mount
Details of the Seismic Mount for high amplitude, low frequency conditions.
Universal Mount
Details of the Universal Mount with adaptable bolt patterns.
Anti-Vibration (Standard) Mount
Details of the Anti-Vibration (Standard) Mount for instrument isolation.
Front Cover Removal
Contact Rating / Breaking capacity
Terminal Block Arrangements
Pocket/Well Installation
Probe Types
Maintenance
Protection Class IP 65
Information on IP 65 protection class and desiccant capsule maintenance.
Mountings with Rubber Dampers - Seismic Type and Universal Type
Maintenance recommendations for vibration dampers on specific mountings.
Gen2 With Transmitter
Technical Data
Technical specifications for the Gen2 transmitter option.
Installation Instructions
Installation guidelines for wiring the Gen2 transmitter.
Table of Contents
Save PDF
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the AKM 345 Gen2 and is the answer not in the manual?
Questions and answers