Siemens 6GK5612-0BA10-2AA3 Commissioning And Hardware Installation Manual

Siemens 6GK5612-0BA10-2AA3 Commissioning And Hardware Installation Manual

Scalance s series industrial ethernet security

Advertisement

SCALANCE S
SIMATIC NET
Industrial Ethernet Security
SCALANCE S
Commissioning and Hardware Installation Manual
05/2016
C79000-G8976-C266-06
___________________
Preface
___________________
Safety notices
___________________
Description
___________________
Deployment planning
___________________
Mounting
___________________
Commissioning
___________________
Troubleshooting/FAQs
___________________
Dimension drawings
___________________
Approvals
1
2
3
4
5
6
7
8
A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6GK5612-0BA10-2AA3 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Preface
Trademarks
Lists registered trademarks of Siemens AG and other names.
Validity of the documentation
Details the SCALANCE S devices covered by the manual and installation guidance.
Notes on configuration
Explains the tools and documentation for configuring SCALANCE S devices.
Information on media modules and SFPs
Points to the section detailing media modules and SFPs for SCALANCE S627-2M.
Safety Notices
General Notices
Provides general safety advice, including warnings about battery replacement.
Information on Use in Hazardous Areas
Details safety precautions for using the device in hazardous environments.
Notices on Use in Hazardous Areas According to ATEX and IECEx
Specifies safety notices for ATEX/IECEx conditions, including temperature and enclosure requirements.
Information on Use in Hazardous Areas According to UL-Hazloc
Outlines safety notices for UL-HazLoc conditions, focusing on explosion hazards.
Information on Use in Hazardous Areas According to UL
Provides safety notices for areas subject to NEC or CEC regulations.
Description
Technical Specifications
Presents detailed technical data including connections, electrical data, and cable lengths.
Hardware Characteristics
Describes essential hardware features like rugged housing, mounting options, and indicators.
Components of the Product
Lists the items included in the SCALANCE S product package.
Power Supply
Explains the power supply requirements, including voltage range and safety extra-low voltage.
Signaling Contact
Details the function, connection, and fault signaling capabilities of the signaling contact.
Displays
Illustrates and describes the various LEDs and indicators on the SCALANCE S device.
Deployment Planning
Unpacking and Checking
Provides instructions for unpacking and inspecting the SCALANCE S device for damage.
Attachment to Ethernet
Explains how to connect the SCALANCE S device to Ethernet networks via its ports.
Reset Button - Resetting Configuration to Factory Settings
Describes how to use the reset button for device restart and factory resets.
C-PLUG (Configuration Plug)
Explains the function, insertion, removal, and replacement of the C-PLUG.
Mounting
Notes on Installation
Provides general guidelines and safety precautions for installing the SCALANCE S.
Types of Installation
Outlines the different methods for installing the SCALANCE S device.
Installation on a DIN Rail
Details the procedure for mounting the SCALANCE S on a 35 mm DIN rail.
Installation on a Standard Rail
Explains how to install the SCALANCE S on a SIMATIC S7-300 standard rail.
Wall Mounting
Describes the fittings and considerations for wall mounting the SCALANCE S.
Grounding
Specifies the grounding methods for different installation types.
Commissioning
Step 1: Connecting Up the SCALANCE S Device
Guides through the initial physical connection of the SCALANCE S device.
Step 2: Configuring and Downloading
Details the process of configuring the SCALANCE S using the Security Configuration Tool.
Troubleshooting and FAQs
Replacing a SCALANCE S Device
Explains how to replace a SCALANCE S device, particularly using a C-PLUG.
Transferring New Firmware
Describes the process and requirements for updating the firmware of a SCALANCE S device.
SCALANCE S Device Does Not Restart Correctly
Provides solutions for issues where the SCALANCE S device fails to restart properly.
SCALANCE S Device Cannot Be Reached
Lists possible causes and troubleshooting steps when the SCALANCE S device is inaccessible.
SCALANCE S Device is Compromised
Explains scenarios where the SCALANCE S device security is compromised and how to address them.
Dimension Drawings
Dimension Drawing for SCALANCE S602 / S612 / S623 Devices
Provides dimensional drawings for SCALANCE S602, S612, and S623 models.
Dimension Drawing for SCALANCE S627-2M Devices
Presents dimensional drawings specific to the SCALANCE S627-2M model.
Approvals
Current Approvals on the Internet
Directs users to online resources for the latest product approvals.
EMC Directive (Electromagnetic Compatibility)
Details compliance with the EMC directive for industrial applications.
RoHS Directive (Restriction of Certain Hazardous Substances)
Outlines compliance with the RoHS directive for hazardous substances.
cULus Approval for Information Technology Equipment
Lists cULus approvals for IT equipment safety standards.
cULus Approval Hazardous Location
Specifies cULus approvals for devices used in hazardous locations.
ATEX (Explosion Protection Directive)
Describes ATEX certification and classification for explosive atmospheres.
IECEx
Details IECEx certification and classification for explosion protection.

Table of Contents