Uponor T-75 Installation Manual
Hide thumbs Also See for T-75:
Table of Contents

Advertisement

R A D I A N T H E AT I N G A N D
C O O L I N G S Y S T E M S
C L I M AT E C O ˘ N T R O L ™
Z O N I N G S Y S T E M
INSTALLATION GUIDE
Climate Co ˘ntrol
Zoning System
Installation Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T-75 and is the answer not in the manual?

Questions and answers

Summary of Contents for Uponor T-75

  • Page 1 R A D I A N T H E AT I N G A N D C O O L I N G S Y S T E M S C L I M AT E C O ˘ N T R O L ™ Z O N I N G S Y S T E M INSTALLATION GUIDE Climate Co ˘ntrol...
  • Page 2 Apple Valley, MN 55124 USA Phone: (800) 321-4739 Fax: (952) 891-2008 www.uponor-usa.com © 2008 Uponor All Rights Reserved. First Edition First Printing May 2008 Printed in the United States of America www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 3: Table Of Contents

    Base Unit With Antenna and Actuators ....3 Interface I-75 ......3 Uponor Climate Co ˘...
  • Page 4: Safety Measures

    Contacting an Installer ..... . . 40 Contacting Uponor ......40 LED on Troubleshooting Solutions .
  • Page 5: Section 2: The Uponor Climate Co ˘ Ntrol Zoning System Overview

    12 thermostats and 14 actuators. The base unit is typically located near the manifolds. The Uponor Climate Co ˘ ntrol Zoning System is a Interface I-75 wireless zoning control for radiant floor systems. The interface allows viewing of important...
  • Page 6: Uponor Climate Co ˘Ntrol Zoning System Components

    • Protect the mounting locations for the Zoning System Language data stick from moisture. • Use one thermostat for every zone with radiant floor heating. www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 7: Components Installation

    2. Use the double-sided adhesive strip to attach the antenna to a smooth wall, such as glazed ceramic tiles. � Connect to terminals 9 and 10. 10 feet www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 8 • Check the actuators and antenna to ensure that the wiring is complete. • Check that the power compartment lid is closed. • Connect the power supply plug into the electrical outlet. www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 9: Section 4: Thermostat Installation

    02, 03, etc. For a system with an interface and several base units, an identification for the base unit should be added, e.g., 1.02, 1.03, 2.02, 2.03, etc. T-75 www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 10: Register Room Thermostats

    Then repeat the steps as outlined in the Register Room Thermostats section on this page. www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 11: Section 5: Thermostat And Base Unit Testing

    The LEDs will switch off for channels linked to this thermostat. The LEDs will not switch off if channels are not linked to this thermostat. Note: If LED remains lit, there is no communication. www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 12: Testing The Base Unit Actuator

    2. Close the cover of the base unit. Close the thermostat covers where necessary. 3. Complete the installation report (Section 12). 4. Leave installation guide at jobsite for future reference. www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 13: Interface Bracket Installation

    8. Secure the cable in the cable guide. 2. Let the screws protrude slightly Maximum cable length: 60 feet from the base unit. 2. Hang the bracket on the screws. www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 14: Connections

    Attention: If a common pump supports multiple manifolds, a pump relay can be Pump Relay connected to the closest base unit. See the circulation pump supplier documentation Pump before performing the connection. www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 15: Time And Date Setup

    The system will automatically return to Advanced mode after 10 minutes. 01 Jan 2008 Interface Keys Uponor screen > Main Menu > Settings > System 1. Check that the wiring is complete. Displays the next Parameters > Controller ID Goes to next field...
  • Page 16: Installation Inspection

    • Check the interface for alarms. 2. Close the base unit cover. 3. Complete the installation report in Section 12. 4. Give this manual and all information about the system to the user. www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 17: Setting The Minimum And Maximum Temperatures

    Increases the value Closing the Thermostat Decreases the Goes to line below value Confirms selection Displays the next and displays the Press screen screen of the current menu www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 18: Interface Screens

    Alarm: A short circuit or similar problem mode. (Current setting is 66.2°F.) is reported. Current status: COMF: Comfort mode. Status ECO: Economy mode > to open the next screen www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 19: Settings Menu

    Setting the Min and Max Temperatures re-editing. In heat mode, ECO mode reduces 1. Uponor screen > Main Menu > Settings > Rooms > Different ECO profiles may be applied to the Editing the ECO Profiles room temperatures at the set times. There are Min / Max Temperatures thermostat for any day of the week.
  • Page 20: Exercise Actuators And Pumps

    > > 1. Uponor screen Main Menu Settings System 1. Uponor screen > Main Menu > Vacation Mode > • Approval and certification: > > • Demand contact: 24VAC at 2 Amps max (not fused) Apply Vacation Mode - KNX: Konnex approval and certification...
  • Page 21: Base Unit Connection Diagrams

    Base Unit Connection Diagram Connection of the interface with the quick connectors (49-foot cable) 110v/60Hz Compartment – Heat-demand Relay 24VDC Heat Demand Power Supply Relay (dry) 110VAC only www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 22: Section 10: System Maintenance

    • Use a dry soft cloth to clean the Zoning System and all its components. Disposal of the Product The Zoning System is made up of various recyclable components. Dispose of them properly. www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 23: Section 11: Troubleshooting

    1.02 Liv. room Battery Alarm ! The cause of the - Resolved - 14 Jun 2008 2 : 01 Resolved alarm in the living room thermostat has been resolved. www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 24: Contacting An Installer

    Contacting Uponor • Interference Communication Error Alarm Base Unit An installer may need to contact Uponor for more Base unit 3 has a communication Communication Error! detailed information. Refer to the information in the error. 19 Dec 2008 1 : 38 >...
  • Page 25: Troubleshooting Solutions

    • Change ECO profile or Thermostat assign another profile to All rooms are cold. the room. • End the ECO period by pressing all thermostat keys. Table 10-1: Troubleshooting Solutions (cont.) www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 26 Base Unit pressed • Replace the thermostat. with Interface For additional issues, contact Uponor Technical Services at (888) 321-4739 (U.S.) or (888) 994-7726 (Canada) • To delete the assignment of the old thermostat and replace with the new one. Radio transmission icon...
  • Page 27: Section 12: Installation Report

    Installer should provide contact information and indicate assignments for base unit(s), channel numbers and rooms. Contact Information ____________________________________________________________________________ Company Name ________________________________________________________________________________ Address_______________________________________________________________________________________ _______________________________________________________________________________________ Phone __________________________ Fax _____________________________ e-mail ______________________ Base Unit Number Channels Rooms Relay 110V Pump www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 28 Option: Option: Base Unit Number Channels Rooms Base Unit Number Channels Rooms Pump Pump www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 29 Notes: www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 30 Notes: www.uponor-usa.com • www.uponor.ca Uponor Climate Co ˘ ntrol™ Zoning System Installation Guide...
  • Page 31 Uponor, Inc. Uponor Ltd. 5925 148th Street West 655 Park Street Apple Valley, MN 55124 USA Regina, SK S4N 5N1 CANADA Tel: (800) 321-4739 Tel: (888) 994-7726 Fax: (952) 891-2008 Fax: (800) 638-9517 Web: www.uponor-usa.com Web: www.uponor.ca...