MPX 1 V1.10 MIDI Implementation Details
typedef struct
{
BYTE global_patch_sources[10];
BYTE global_patch_destinations[10];
}GLOBAL_PATCHES;
Bypass Controllers Dump (Type 0x012C in V1.00; 0x012D in V1.10)
This dump allows you to send "Bypass Controllers" assignments to, or receive them from the system. The
bypass controllers allow the operator to define a particular controller to toggle the effects and system
bypass on and off. The 7 bypass controllers are assigned as follows:
0 - Master Bypass
1 - Pitch Bypass
2 - Chorus Bypass
3 - Modulation Bypass
4 - EQ Bypass
5 - Reverb Bypass
6 - Delay Bypass
The dump consists of seven 1-byte controller sources that can be patched to these destinations. The
sources are the controllers from Appendix A; Controller Indeces beginning with "Tog1" (0x19) and ending
at "CC119" (0x96). A value of 0xFF is used if the controller is unassigned ("None" displayed).
Remap Controllers Dump (Type 0x012B in V1.00; 0x012C in V1.10)
This dump allows you to send "Remap Controllers table" assignments to, or receive them from the system.
The remap controllers table is used by the system to define the MIDI controller number which will be used
to transmit the control source if it is used in a patch and has a non-0xff value in this table. The value 0xff
designates "not assigned". The system supports 163 controller sources (listed in Appendix A) which each
have an associated remap value in the remap table. The table in the Appendix identifies the assignment
of each byte of this dump sequentially.