Storage Tab: User-Defined Application Properties - HP X1600 - StorageWorks Network Storage System 5.4TB SAS Model NAS Server User Manual

Automated storage manager
Hide thumbs Also See for X1600 - StorageWorks Network Storage System 5.4TB SAS Model NAS Server:
Table of Contents

Advertisement

Storage tab—Displays the user-defined application's storage space, including allocated space,
used space, free space, and the following storage allocation details:
Table 21 Storage tab: User-defined application properties
Property
Application Path
Protocol
Application Server Host Name
Application Server Volume -
Name
Application Server Volume -
Status
Application Server Volume - Ex-
clusive Storage
Application Server Volume - RAID
Level
Application Server Volume - RAID
Stripe Size
Application Server Volume - Read
Cache
Application Server Volume -
Write Cache
Application Server Volume -
Number of Hot Spares
Application Server Volume -
Mount Paths
Warning Threshold tab—Allows you to change the percent full warning threshold value for the
user-defined application. See
ation.
Snapshots tab — Allows you to schedule snapshots of the user-defined application. For more in-
formation, see
"Scheduling and running
Backup tab — Allows you to schedule backups of the user-defined application. See
"Scheduling
backups" on page 36 for more information.
Replication tab — Allows you to configure data replication of the user-defined application. See
"Running
replication" on page 40 for more information.
Value
Path to the file directory on the application server where the user-defined
application data is saved by the user-defined application. The file dir-
ectory is located on the volume created on the iSCSI LUN that was ex-
ported by ASM to the application server.
Communication protocol used to transfer data between the server that
hosts the user-defined application and your HP Storage System.
Name of server that hosts the user-defined application.
Name of the volume on the application server to which the user-defined
application saves its data. The volume resides on the iSCSI LUN (logical
disk) exported by ASM to the application server.
Status of the volume on the application server where the user-defined
application data is stored.
Indicates if user-defined application storage is configured with exclusive
storage. See
Table 5
on page 23 for more information.
The RAID level to which the user-defined application storage is con-
figured. See
Customizing RAID levels
The RAID stripe size to which the user-defined application storage is
configured. See
Table 5
Speeds up reads when enabled. This setting is determined by the stor-
age array, not ASM.
Speeds up writes when enabled. This setting is determined by the stor-
age array, not ASM.
The number of hot spares with which the database component storage
is configured. See
Table 5
Path the application server volume is mounted on. The volume is built
on the iSCSI LUN exported by ASM to the application server.
Setting a percent full warning threshold
snapshots" on page 33.
HP StorageWorks X1000 Automated Storage Manager
on page 25 for more information.
on page 23 for more information.
on page 23 for more information.
on page 26 for more inform-
57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks x1000