HP StorageWorks
Storage server 2U fixed rail in-
stallation instructions
This document provides procedures for installing a 2U-
size storage server into a rack using fixed rails (non-
sliding). HP assumes that you are qualified in servicing
computer equipment, and trained in recognizing haz-
ards in products with hazardous energy levels.
© Copyright 2007 Hewlett-Packard Development Company, L.P.
First edition (February 2007)
The information in this document is subject to change without notice.
Printed in the US
www.hp.com
*440929-001*
Rail hardware
1
Right rail assembly
2
Left rail assembly
WARNING!
Before you begin, make sure that the rack is sufficiently stable.
If provided, lower the rack leveler feet and make sure any re-
quired stabilizers are installed. If provided, extend the rack anti-
tip device. Failure to extend the anti-tip device could result in
personal injury or damage if the rack tips over.
Install the rails in the rack
NOTE:
If the holes in the rack uprights are round instead of square, re-
move the standard pins from the rails and replace them with the
round-hole pins provided with the rail kit. The pins are load-
bearing. Do not remove the standard pins except to replace
them with the pins for round-hole racks.
1.
Identify the left (L) and right (R) rack rails by markings stamped into
the rails.
2.
Insert the rear end of the right rack rail into the inside back of the
rack until the pins extend through the holes in the rack upright.
Squeeze the scissor-type locking latch to enable the latch and pins
to extend through the rack holes.
CAUTION:
Be sure that the scissor-type locking latch engages when
the end of the rail seats into the rack uprights.
3
Rail pins

Advertisement

loading

Summary of Contents for HP DL320s - ProLiant 9TB SATA Storage Server NAS

  • Page 1 Install the rails in the rack NOTE: © Copyright 2007 Hewlett-Packard Development Company, L.P. If the holes in the rack uprights are round instead of square, re- First edition (February 2007) move the standard pins from the rails and replace them with the round-hole pins provided with the rail kit.
  • Page 2 Pull off the storage server side covers to expose the thumbscrews on each side. Secure the server to the front of the rack using the thumbscrews (2). Reattach the storage server side covers. Extend the front end of the rail toward the inside front of the rack. Pull the safety latch to release the scissor-type lock latch and squeeze Secure the server in the rack the scissor-type latch together to insert the rail and pins through the...