Summary of Contents for Yaesu FTDX5000 - CAT OPERATION REFERENCE BOOK
Page 1
PERATION OMPUTER IDED RANSCEIVER 5000 ERIES CAT O PERATION EFERENCE 5000 S CAT O ERIES PERATION EFERENCE...
Page 2
PERATION OMPUTER IDED RANSCEIVER CAT J VERVIEW The CAT (Computer Aided Transceiver) System in the 5000 series provides control of frequency, VFO, memory, and other settings such as dual-channel memo- ries and diversity reception using an external personal computer. This allows multiple control operations to be fully automated as single mouse clicks or keystroke op- erations on the computer keyboard.
Page 3
PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND Parameters A computer control command is composed of an alpha- betical command, various parameters, and the terminator Parameters are used to specify information necessary to that signals the end of the control command. implement the desired command. Example: Set the main band (VFO-A) frequency to The parameters to be used for each command are prede- 14.250000 MHz.
Page 4
PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND OMMAND UNCTION OMMAND UNCTION VFO-A TO VFO-B MEMORY READ ANTENNA TUNER CONTROL METER SW AF GAIN MEMORY WRITE AUTO INFORMATION MOX SET VFO-A TO MEMORY CHANNEL NARROW ANTENNA NUMBER NOISE BLANKER VFO-B TO VFO-A NOISE BLANKER LEVEL AUTO NOTCH NOISE REDUCTION...
Page 5
PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES VFO-A TO VFO-B Read Answer A A A A A C C C C C ANTENNA TUNER CONTROL P1 0: Fixed P3 0: Tuner “OFF” P2 0: Fixed 1: Tuner “ON” P1 P2 P3 2: Tuning Start Read Answer...
Page 6
PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES BREAK-IN P1 0: Break-in “OFF” 1: Break-in “ON” Read Answer MANUAL NOTCH P1 0: Main (VFO-A) Band Receiver P3 When P2=0 1: Sub (VFO-B) Band Receiver 000: OFF P1 P2 P3 P3 P3 P2 0: Manual NOTCH “ON/OFF”...
Page 7
PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES CONTOUR P1 0: Main (VFO-A) Band Receiver P3 When P2=0, 1: Sub (VFO-B) Band Receiver 000: CONTOUR/APF “OFF” P1 P2 P3 P3 P2 0: CONTOUR/APF “ON/OFF” 001: CONTOUR “ON” Read 1: CONTOUR FREQUENCY 002: APF “ON”...
Page 8
PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES ENCORDER UP P1 0: MAIN ENCORDER 1: SUB ENCORDER P1 P2 P2 2: MAIN Select Read 3: SUB Select P2 01-99: Steps Answer MENU P1 : 001-176 (MENU Number) P2 : Parameter P1 P1 P1 P2 P2 See Table 1 - Table 3 Read P1 P1 P1...
Page 9
PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES ABLE FUNCTION BYTE 0: 15, 1: 20, 2: 25, 3: 30 (msec) DATA IN SELECT 0: DATA, 1: PC DATA TX GAIN 000~100 DATA OUT 0: VFO-A, 1: VFO-B DATA OUT LEVEL 000~100 DATA VOX DELAY 0030~0300~3000msec (10msec/step) DATA VOX GAIN...
Page 11
PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES F F F F F A A A A A FREQUENCY VFO-A P1 00030000 - 60000000 (Hz) P1 P1 P1 P1 P1 P1 P1 P1 Read Answer P1 P1 P1 P1 P1 P1 P1 P1 FREQUENCY VFO-B P1 00030000 - 60000000 (Hz) P1 P1 P1 P1 P1 P1 P1 P1...
Page 12
PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES IF IF INFORMATION P1 001-117 (Memory Channel) P2 VFO-A Frequency (Hz) P3 Clarifier Direction +: Plus Shift, -- : Minus Shift Clarifier Offset: 0000 - 9999 (Hz) Read P4 0: RX CLAR “OFF” 1: RX CLAR “ON”...
Page 14
PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES METER SW P1 0: COMP 1: ALC 2: PO Read 3: SWR 4: ID Answer 5: VDD MEMORY CHANNEL WRITE P1 Memory Channel Number P2 Memory Channel Frequency (Hz) P3 Clarifier Direction +: Plus Shift, -- : Minus Shift P1 P1 P1 P2 P2 P2 P2 P2 Clarifier Offset: 0000 - 9999 (Hz) P4 0: RX CLAR “OFF”...
Page 15
PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES OFFSET (REPEATER SHIFT) P1 0: Main (VFO-A) Band 1: Sub (VFO-B) Band P1 P2 P2 0: Simplex Read 1: Plus Shift 2: Minus Shift Answer : FM mode only P1 P2 P P P P P A A A A A PRE-AMP (IPO)
Page 16
PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES QUICK SPLIT Read Answer RF ATTENUATOR P1 0: Main (VFO-A) Band Receiver 1: Sub (VFO-B) Band Receiver P1 P2 P2 0: OFF Read 1: 6 dB 2: 12 dB Answer 3: 18 dB P1 P2 R R R R R C C C C C CLAR CLEAR...
Page 17
PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES R R R R R O O O O O ROTATOR P1 0: OFF 1: Counter Clockwise 2: Clockwise Read 3: SPEED 1 % DOWN 4: SPEED 1 % UP Answer P2 DIRECTION (0 - 450) P3 SPEED (0 - 100 %) P1 P2 P2 P2 P3 P3 P3 RADIO STATUS...
Page 18
PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES S-METER READING P1 0: Main (VFO-A) Band S-meter 1: Sub (VFO-B) Band S-meter P2 000 - 255 Read Answer P1 P2 P2 P2 SQUELCLH LEVEL P1 0: Main (VFO-A) Band Receiver 1: Sub (VFO-B) Band Receiver P1 P2 P2 P2 P2 000 - 255 Read...
Page 19
PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES V V V V V G G G G G VOX GAIN P1 000 - 255 P1 P1 P1 Read Answer P1 P1 P1 VFO-A TO MEMORY CHANNEL Read Answer VFO SELECT P1 0: VFO-A 1: VFO-B Read Answer...
Page 20
PERATION OMPUTER IDED RANSCEIVER Copyright 2010 VERTEX STANDARD CO., LTD. All rights reserved No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO., LTD. 5000 S CAT O ERIES PERATION EFERENCE...