Download Print this page

Yaesu FT-2000D - UPDATE V0151 AND V11.54 INFORMATION Update Manual page 2

Main cpu ver. 0151 and edsp ver. 11.54

Advertisement

Ver. 0151 MAIN CPU implements improvements (also includes all previous updates):
AGC: Corrected the AGC in the "OFF" position; if an AGC MENU SET item was changed, the AGC
would sometimes turn "ON".
KEYER: The extraneous "dot" memory is eliminated during rapid keying when the dash output starts.
CAT: Corrected the 1.5 kHz shift when the CAT "FA" command is used to change the frequency on
the 5MHz band.
SCOPE: The right edge signal position on the display is corrected.
SCOPE: The left edge signal is corrected when the frequency is changed on the display.
Ver. 11.54 EDSP implements improvements (also includes all previous updates):
Corrected FM TX for a slight frequency offset.
NOTES:
*Rotate the [METER] switch to select "COM" (Compression). We recommend setting the PROC level within the 5dB
to 10dB range.
*When menu settings are saved on the DMU-2000 CF card and transferred to the new version, some previous versions
may not transfer correctly. Please check your menu, update the settings, and then save the new settings to the CF card.
1. Down load the FT-2000 data file [FT-2000_PEP2000_4-23-10.zip] from the following website:
http://www.yaesu.com/indexVS.cfm?cmd=DisplayProducts&ProdCatID=102&encProdID=66EA
91711DFB68C03DED4AD35153E12C&DivisionID=65&isArchived=0
2. Save the FT-2000 data file [FT-2000_PEP2000_4-23-10.zip] to the desktop on your computer.
3. Unzip and Extract the contents of [FT-2000_PEP2000_4-23-10.zip] to the desktop of your
computer.
4. You will find the PEP2000_EDSP3 and PEP2000_MAIN folders on your desktop.
The programmers and software are now stored on your computer on the desktop. The files designated
in the last step above are ready to update your FT-2000/D Transceiver.
This procedure is used for uploading new Software into the FT-2000/D Amateur Transceivers using
the CT-119 program cable. If you have the 8pin mini-DIN PGM-SW (P0091526) refer to the 8-pin
mini-DIN PGM-SW page 4.
*Don't forget to write down (or save to a CF Card) any personal menu settings you have changed from the
default before you start. Please see the DMU-2000 Data Management Operation Manual for the procedure
to save your settings to a CF card.
(1)
Turn off the main power switch located on the back of the FT-2000 (or turn off the power
supply for FT-2000D and wait a minute, until the capacitors discharge) and remove the AC
power cord.
Install the data file to PC
MAIN Software Update

Advertisement

loading

This manual is also suitable for: