Download Print this page

ClosetMaid SHELFTRACK 32836 Manual

Nickel hang track rail, closet system hardware

Advertisement

Quick Links

01-11324-12
80 in. Hang Track
203,2 cm Rail Horizontal
203,2 cm Riel Horizontal
32836
WARNING
• Failure to obey installation
Products of China
instructions and warnings can
Produits de la Chine
result in injury or death.
Productos de China
• Use correct hardware for wall type.
© 2018 ClosetMaid LLC
When using standards with hang
Ocala, FL 34471
track, standards must be secured
1-800-874-0008 (USA, Canada)
to the wall. Do not overload.
www.closetmaid.com
MISE EN GARDE
ADVERTENCIA
• Ne pas se conformer aux directives d'installation
• Puede causar herida y hasta la muerte si no
et aux consignes de sécurité peut occasionner des
se observan las instrucciones y advertencias
blessures ou même la mort.
para la instalación del producto.
• Utilisez le matériel de fixation convenant au type
• Use el herraje que corresponda según el tipo
de mur. Lorsque vous utilisez des rails verticaux
de pared. Cuando usando los rieles verticales
avec rails horizontaux, les rails verticaux dovient
con los rieles horizontales, los rieles verticales
être fixés solidement au mur. Ne pas surcharger.
se deben fijar a la pared. No sobrecargue.
FOR STUD INSTALLATION: Secure to the wall with #12x2 in. pan head screws directly into studs.
FOR CONCRETE INSTALLATION: Drill 1/4 in. holes and insert #12 wall anchors. Secure to the wall using #12x2 in. pan head screws.
FOR DRYWALL INSTALLATION: Drill 1/2 in. holes. Remove toggle from bolt and insert bolt through hang track or standard. Then, re-attach toggle to bolt and insert toggle into wall.
Tighten bolt to secure to wall.
1. Install Hang Track: At desired height, level Hang Track with overhang positioned at top. Mark hole locations every 16 in. for studs and every 8 in. for concrete or drywall. Secure to wall.
2. Install Standards: Locate notched end of Standard. Place Standard onto Hang Track so notch fits over bottom rail. Space Standards no more than 24 in. apart.
3. Install Brackets: Insert Brackets into Standards at desired heights.
4. Install shelving: Position shelf so Bracket nose fits between wires on front of shelf. Push shelf back and position back wire behind hooks on back of Brackets. Press shelf down to lock into place.
5. Secure Standards: Locate and mark hole closest to center point of EACH Standard. Swing Standard to one side (DO NOT PULL STANDARDS AWAY FROM WALL.) and drill hole. For concrete and
drywall walls, install anchor or toggle. Reposition Standard back over hole and secure to wall.

Advertisement

loading
Need help?

Need help?

Do you have a question about the SHELFTRACK 32836 and is the answer not in the manual?

Questions and answers

Summary of Contents for ClosetMaid SHELFTRACK 32836

  • Page 1 • Use el herraje que corresponda según el tipo 203,2 cm Rail Horizontal 3. Install Brackets: Insert Brackets into Standards at desired heights. © 2018 ClosetMaid LLC When using standards with hang de mur. Lorsque vous utilisez des rails verticaux de pared.
  • Page 2 End caps protect you, your clothing and the shelving materials. ClosetMaid Superslide shelf system is manufactured by ClosetMaid LLC., Orlando, Florida. Manufacturer reserves the right to change specifications without notice. ® 13485 Veterans Way Orlando, Florida 32827 1-800-874-0008 US: closetmaidpro.com, closetmaid.com...