Carrier 42KWS09VS User Manual And Installation Manual
Carrier 42KWS09VS User Manual And Installation Manual

Carrier 42KWS09VS User Manual And Installation Manual

Window type split air conditioner

Advertisement

Quick Links

Advertisement

loading
Need help?

Need help?

Do you have a question about the 42KWS09VS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carrier 42KWS09VS

  • Page 2 Safety precautions Product features User instructions Air conditioner components Remote operation Maintenance methods User Experience Guide Fault Inspection Selection of installation location Electrical installation requirements Installation of indoor units Installation of outdoor units Trial operation Packing List Use authorized disposal sites for your old appliance. Help to keep your country tidy! This appliance is using R32 mildly flammable refrigerant.
  • Page 3 WARNING CAUTION...
  • Page 9 The amount Maximum Horse Minimum refrigerant of refrigerant Minimum room Model refrigerant that can be area Power height (m) charging amount charge added additionally 42KWS09VS 0.12 0.82 38KWS09VS 42KWS12VS 0.12 0.82 38KWS12VS 42KWS18VS 0.75 0.18 0.93 38KWS18VS 42QWS09VS 0.12 0.82 38QWS09VS 42QWS12VS 0.12...
  • Page 10 , , , , This product contains fluorinated greenhouse gases and its function relies on these. = Manufacturing Charge(Indicated on the nameplate) = Additional Charge(See the instructions in the manual) = Total Amount • • • •...
  • Page 11: Features Of This Product

    Features of this product Using world-renowned compressors and microcomputer control chips, the working performance is stable and reliable. The use of high-efficiency compressors and high-efficiency heat exchangers results in higher efficiency and more significant energy savings. Adopting non equidistant through flow blades, large wind wheels, and stepper motors to drive the wind pendulum, achieving silent operation.
  • Page 13 From left to right, they are automatic, refrigeration, dehumidification, heating, and air supply; On the left is a child lock, and on the right is a sleep pattern; The swinging pattern is often displayed, including up and down swinging and left and right swinging (manual); The left side is the fresh air pattern (reserved), and the right side is the Follow me pattern (reserved).
  • Page 14 6. Digital display: timed status displays timed time, timed on continuously displays timed time, timed off After completing the interval setting, delay for 5 seconds to switch to the pre timer state; Automatic, refrigeration, dehumidification, and heating display set temperature; The signal pattern in the upper right corner flashes when there is signal transmission, in order of timing unit and ℃...
  • Page 16 upwind area Stationar automatic up-and- Pull the horizontal airflow down swing direction guide plate by move in cycles hand to adjust the left and right wind directions. upwind area adown Press the "Wind Direction" key once, and the leveling air door will swing automatically.
  • Page 17 : : ℃ : ℃ : ℃ : ℃...
  • Page 18 Immerse the cloth in warm or cold water below 40 ℃, wring it dry before wiping. Wash with a soft sponge like substance and thoroughly wipe off any moisture. When it is very dirty, a neutral cleaning agent can be used. 1.
  • Page 19 Unable to operate Compressor is running or stopping Heating operation without heating blowing out Poor cooling effect or heating effect High operating noise Remote control display is abnormal The air conditioner is leaking condensate water...
  • Page 20 During installation, the unit must be reliably grounde Please entrust local dealers or service outlets to arrange professional personn with air conditioning installation certificates to install. Users are strictly prohibited from installing on their own. Before connecting the power to the air conditioner, be sure to carefully che whether the wiring and piping are completely correct and secure.
  • Page 21 3. . Places that are not easily accessible to childre 4. . Places where strong winds are difficult to reac 5. . Operating noise or blowing hot air does not affect neighboring area 6. . It should be firmly installed on a sturdy platform to avoid increased vibration noise.
  • Page 22 2. The grounding wire must use yellow/green wires with sufficient wire diameter, and it is strictly prohibited to connect it to water pipes, gas pipes, neutral wires, and lightning protection lines. 3. When wiring, it is necessary to refer to the electrical circuit diagram pasted inside the machine and ensure that the actual object is correct before connecting.
  • Page 23 front back right back down left rear left Cut off this part when piping to the left. Cut off this part Cut off this part when when piping to the piping on the lower side. right.
  • Page 26 Counterbore pipe tube carrier Check Compare the flaring operation with the following Install the nut legend. If the flaring operation is defective, the Remove the connecting nuts installed on flaring part shall be cut off before the flaring indoor and outdoor units, and put the operation.
  • Page 27 Connect the pipeline to the shut-off valve opening of the outdoor unit using the same method used for indoor units. Use a wrench to clamp the wide body, use a torque wrench to clamp the connecting nut, and use the same tightening torque as the indoor unit to connect the pipeline to the outdoor unit.
  • Page 28 Indoor unit Brown Blue Black Yellow Green Outdoor terminal block Shell Brown Blue orange Outdoor Electric Control Note: If the above diagram is consistent with the wiring diagram on the machine Not completely consistent, please refer to the one on the machine.
  • Page 29 globe valve (three end valve) globe valve composite vacuum (two end valve) auxiliary air pressure gauge port pressure gauge confluent valve handle Hi handle inflatable hose inflatable hose vacuum pump...
  • Page 30 ℃ ℃ ℃ ℃ ℃ ℃...
  • Page 31 Some systems require additional charging depending on pipe lengths. The standard pipe length varies according to local regulations. For example, in North America, the standard pipe length is 7.5m (25’). In other areas, the standard pipe length is 5m (16‘). The refrigerant should be charged from the service port on the outdoor unit’s low pressure valve.