EAW UXA4807D User Manual
EAW UXA4807D User Manual

EAW UXA4807D User Manual

Advertisement

Quick Links

UXA4807D
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UXA4807D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EAW UXA4807D

  • Page 1 UXA4807D User Manual...
  • Page 2: Safety And Environmental Notices

    Technical and Safety Notices Please read the following important technical, safety Safety and Environmental Notices and environmental notices before installing and using Note: The intent of the lightning flash with arrowhead symbol in a your amplifier. triangle is to alert the user to the presence of uninsulated “dangerous” Technical Notices voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans.
  • Page 3: Important Safety Instructions

    Technical and Safety Notices Important Safety Instructions Environmental Statement Read these instructions. This product complies with international directives, Keep these instructions. including but not limited to the Restriction of Heed all warnings. Hazardous Substances (RoHS) in electrical and Follow all instructions. electronic equipment, the Registration, Evaluation, Do not use this apparatus near water.
  • Page 4: Introduction And Overview

    Introduction and Overview 1. Introduction 2. Amplifier Overview UXA4807D amplifiers are a full rack width, 2U format power UXA4807D power amplifiers have been designed to amplifiers that can drive both conventional low impedance (Lo-Z, provide configurable, consistent and reliable high 4Ω...
  • Page 5: Carton Contents

    • Input connector x 2 or 4 configuration menus. The configuration menus are accessed via • GPIO socket connector x1 the UXA4807D control web app interface and cover Input, Zone, • Output connector x 1, 2 or 4 Output and General Settings functions. The configuration menus •...
  • Page 6: Installation

    (19 inch) equipment rack installation. If the amplifier will not be installed in an equipment rack, UXA4807D amplifiers can be placed free-standing on a flat surface. Adhesive rubber feet are supplied for this purpose. It is important that any installation provides space for airflow through the ventilation apertures at the front and rear of the amplifier.
  • Page 7 Installation Diagram 4B UXA4807D amplifier with rear support brackets fitted. Rear Support + Button + 1 x M4 x 8 each side...
  • Page 8 5.2.2 Wireless (WiFi) Network Connection supply and can be used with mains input voltage from 100V AC to To connect a UXA4807D amplifier to a TCP/IP network using a 240V AC, 50/60Hz. Use the mains cable supplied with the amplifier wireless connection (WiFi) follow the steps below.
  • Page 9: Configuration Menus

    5.3 Configuration Menus 5.3.1 Input Tab The Input Tab provides naming, mono/stereo selection, Opening a web browser that is network connected to a UXA4807D sensitivity, and gain trim for each amplifier input channel. An amplifier initially displays the UXA4807D Control Web App internal pink noise source, provided for system testing and set up, Dashboard illustrated in Diagram 5a.
  • Page 10 Web App Configuration 5.3.2 Zone Tab The Zone Tab enables installation zones to be defined and named, and provides access to further sub-menus. Zones might be bar or restaurant areas for example, or different rooms in a home. For all Zone Tab menus, the installation zone under configuration is selected by highlighting one of the zone identifiers (A, B, C or D) at the top of the page.
  • Page 11 The Output Tab also enables Speaker Preset configurations to be created, exported, imported or cleared. Note:: The number of individual outputs available for configuration will depend on the UXA4807D amplifier model and the input, zone and output mode configuration. •...
  • Page 12 1. Select either the IMPORT PRESET FROM FILE or SELECT PRESET FROM LIBRARY (EAW Library available at EAW.com) option from the Speaker Preset menu. If no import option is visible, select CLEAR to delete any existing speaker preset data.
  • Page 13 Web App Configuration Diagram 5k • The Speaker EQ in the preset menu allows for configuring Speaker Preset applied customized parametric EQ on the output level. (Diagram 5m). Diagram 5m The Crossover & Gain in the preset menu allows for •...
  • Page 14 Web App Configuration • Driver Alignment in the preset menu will allow for delay to be set between driver passbands (Diagram 5o). Diagram 5o Preset Driver Alignment The Polarity preset menu enables the polarity of individual • Diagram 5q amplifier outputs to be reversed (Diagram 5p). Preset Limiter The Output Mode preset menu enables individual amplifier •...
  • Page 15 A firmware update routine and identifier button can also be found under the Device menu. Current Firmware may be found at eaw.com under Downloads then DSP Settings. The Backup & Restore menu enables amplifier configuration •...
  • Page 16 Web App Configuration Diagram 5u Signal Flow Schematic...
  • Page 17 Input Priority or Input Ducking to be configured. The Input Priority function enables an alternative input to replace Opening a web browser that is network connected to a UXA4807D and mute the input primarily routed to the zone under...
  • Page 18 5.5 GPIO Setup and Connection Diagram 5w GPIO Settings Menu UXA4807D amplifiers provide a GPIO socket that enables remote control of volume, standby, mute and trigger functions. The GPIO connector pin functions are described in the GPIO Settings menu illustrated in Diagram 5v. The connection of GPIO based remote volume control and standby/mute are illustrated in Diagram 5w and Diagram 5x respectively.
  • Page 19: Resolution Configuration

    Resolution Configuration 6. Configuring UXA Installation Amplifiers in Resolution 2 The Network View Processor shows an overview of the Zones and Outputs in the amplifier. Outputs that are fed by a Zone will appear beside the associated Zone The main window provides an overview of the amplifier state. The main sections of the amplifier can be navigated using the top-row tabs.
  • Page 20 Resolution Configuration The LAN and WIFI addresses are also shown and can help indicate if the proper network connections have been made. Each Zone on the amplifier is shown in the overview. Also indicated are the input source to the zone, and the output channels that the zone feeds.
  • Page 21 Resolution Configuration The input sensitivity can be controlled using the following buttons illustrated on the right. Each analog input has a five band equalizer. The type of each band can be changed to PEQ, High/Low pass, or High/Low shelf. In addition, there is a fixed 100Hz High Pass filter that may be toggled on or off. Each EQ point can be controlled in EQ Filters.
  • Page 22 Resolution Configuration Channel linking supports grouping channels that share a subset of EQ settings. Any adjustments made to a shared EQ control on one channel will be propagated to all channels in the group New groups can be created. The first channel added to the group will define the initial EQ settings. A channel can be added to a group by selecting the group number in the drop down box.
  • Page 23 Resolution Configuration The Mixer input channel supports mixing Analog, SPDIF, and Dante inputs into a single mixed input. Each input channel has a gain control and meters. The Generator input provides Sine Wave and Pink Noise signals as input sources. The volume limit of the generator can be set from -48dB to 0dB.
  • Page 24 Resolution Configuration 6.2 Zone Channels Tab Zones provide input control for outputs. Each zone has a primary input source and a priority source. The priority source can be set to automatically override the primary source, based on signal detection, for important announcements or emergencies. Zones support Stereo channels, volume level, and mute.
  • Page 25 Resolution Configuration The priority input selection defines an alternate input source used to interrupt the current signal when announcements or emergency signals need to be made. There are two modes for signal detection. Priority mode is used to interrupt the primary source signal when a minimum Threshold level is detected on the priority input.
  • Page 26 Resolution Configuration The Zone Volume controls are used to configure the range and external control of the Zone volume. “Volume Range” can be set to minimum and maximum values. Doing so will prevent the gain control from being adjusted beyond these limits. “Allow Mute”...
  • Page 27 Zones provide the input source to an Output channel. Each output has equalization and delay. EAW Greybox presets provide optimized settings for EAW loudspeakers. Each amplifier can store a library of speaker presets. Resolution comes with a list of the most recent preset revisions.
  • Page 28 Resolution Configuration The Routing section defines the Zone input source to the output channel. If the selected Zone source is a stereo input, then a the stereo channel must be chosen as the input to the Zone, or a sum of the ;eft and right channels. The output equalizer can be enabled or disabled on the output channel.
  • Page 29 Resolution Configuration System Information provides user editable information about the amplifier along with installation notes with a limit of 512 characters System Information provides user editable information about the amplifier along with installation notes with a limit of 512 characters A password can be set on the amplifier that governs access to the amplifier through the web interface.
  • Page 30 Resolution Configuration The GPIO settings are used to specify what each GPIO pin is used for. For Zone Volume control, setting a GPIO, such as Pin 4, will allow that pin to be selected as the volume control on any Zone channel. Output routing is used to route input audio signals directly to S/PDIF or Dante outputs.
  • Page 31 Resolution Configuration The WIFI settings under the Network Tab control connection through the WIFI Under LAN Settings on the Network Tab the amplifier can be configured to have a DHCP or Static IP address. Changes must be applied to take effect. Power usage can be configured on the Power tab.
  • Page 32 Resolution Configuration This tab is useful for viewing differences between the preset library in Resolution and the library on the amplifier. Presets that are not available in both places are indicated by orange shading. The current library in Resolution can be sent to the amplifier using the Send button. Sending a preset library to the amplifier will overwrite its current library.
  • Page 33 (–) amplifier terminals always connected Analog Inputs to negative speaker terminals. UXA4807D analog inputs are of line level format with a default input sensitivity of +4dBu (full output voltage swing/ In the case of Hi-Z speaker connections, the two speaker cable sensitivity) in all output modes.
  • Page 34 Connections Diagram 7A UXA4807D rear panel connections...
  • Page 35 Connections 7.4 Speaker Cable Gauge Cable Gauge Table Lo-Z installations, 0.5dB attenuation. 2 Ω, 4 Ω & 8 Ω loads UXA4807D speaker connection cable gauge should be Max Cable Max Cable Max Cable Cable Cross chosen appropriately to reflect the type of installation.
  • Page 36 Connections Diagram 7B Two and four output amplifier balanced analog input cable connections. 5 mm Low-Z Mode 5 mm Diagram 7C Two and four output amplifier Output cable connections. Hi-Z/BTL Modes 5 mm Note: Eight channel amplifiers employ a larger output connector.
  • Page 37 Connections Diagram 7D Two and four output amplifier GPIO cable connections. 5 mm Diagram 7E Eight output amplifier balanced analog input cable connections. 5 mm...
  • Page 38 Connections Diagram 7F Eight output amplifier Output cable connections. 5 mm Low-Z Mode 5 mm Hi-Z/BTL Mode Diagram 7G Note: Two and four channel amplifiers Eight output amplifier GPIO employ a smaller output connector. cable connections. 5 mm...
  • Page 39: Operation

    Audio will be heard from any connected speakers. • Disconnect the amplifier from mains power. Note: UXA4807D amplifiers will by default not wake from Standby • Press and hold the front panel power button while Mode unless an input signal is present, a network ‘ON’ command is simultaneously reconnecting mains power.
  • Page 40: Specifications

    SPECIFICATIONS Channels 4 Inputs, 8 Outputs Output power @ 2.7ohms 8 x 1200W* 8 x 800W Output power @ 4ohms 4 x 2500W (BTL)* 8 x 400W Output Power @ 8ohms 4 x 1500W (BTL) Output Power 70V 4 x 1200W (BTL) Output Power 100V 4 x 1500W (BTL) Total System Power...
  • Page 41 19 National Drive Franklin, MA 02028 Quickstart Guide tel 800 992 5013 / +1 508 234 6158 www.eaw.com ©2025 Eastern Acoustic Works All rights reserved. Products are not drawn to scale. All terms, conditions, and specifications subject to change without notice.

Table of Contents