Elkay EZS8WS 1A Series Installation, Care & Use Manual
Elkay EZS8WS 1A Series Installation, Care & Use Manual

Elkay EZS8WS 1A Series Installation, Care & Use Manual

Bottle filling station & cooler

Advertisement

EZSTL8WS*1A
EZS8WS EZH2O B
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELEC-
TROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS
PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN
FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT THE BOTTLE FILLING STATION AND WATER
COOLER BE PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI).
INSTALLER
EZS8WS Bottle Fillers are among the easiest to install on the market today. To
insure you install these models easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND
OTHER APPLICABLE CODES. After installation, leave these instructions with the
Fountain for future reference.
EZS8WS*1A
EZS8WS*2A
EZSTLR8WS*1A
EZSTL8WS*2A
T M
OTTLE
EZS8WS*3A
EZSDWS*1A
EZSTL8WS*3A
INSTALLATION, CARE & USE MANUAL
F
S
ILLING
TATION
IMPORTANT
THIS IS AN INDOOR APPLICATION ONLY.
ALL SERVICE TO BE PERFORMED BY AN
AUTHORIZED SERVICE PERSON.
TOOLS REQUIRED
BUT NOT PROVIDED:
SAFETY GLASSES
GLOVES
ELECTRIC DRILL
3/4" WRENCH OR CRECENT WRENCH
5/16" NUT DRIVER
UTILITY KNIFE
TAPE MEASURE
PENCIL
CENTER PUNCH
1/2" SOCKET & RATCHET WRENCH
5/32" ALLEN WRENCH
Page 1
https://manual-hub.com/
EZSTLDWS*1A
& C
OOLER
98706C (Rev. D - 9/11)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EZS8WS 1A Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Elkay EZS8WS 1A Series

  • Page 1 EZS8WS*1A EZS8WS*2A EZS8WS*3A EZSDWS*1A EZSTL8WS*1A EZSTLR8WS*1A EZSTL8WS*2A EZSTL8WS*3A EZSTLDWS*1A INSTALLATION, CARE & USE MANUAL EZS8WS EZH2O B & C OTTLE ILLING TATION OOLER IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON. TOOLS REQUIRED BUT NOT PROVIDED: SAFETY GLASSES...
  • Page 2 EZS8WS*1A EZS8WS*2A EZS8WS*3A EZSDWS*1A EZSTL8WS*1A EZSTLR8WS*1A EZSTL8WS*2A EZSTL8WS*3A EZSTLDWS*1A 17 7/8 454mm 3 9/16 90mm 178mm 178mm 7/16 11mm MOUNTING HOLES 18 13/16 478mm 381mm Single Rough-In Fig. 1 17 7/8 454mm 3 9/16 90mm 178mm 178mm 7/16 11mm MOUNTING HOLES 18 13/16 478mm 381mm...
  • Page 3 EZS8WS*1A EZS8WS*2A EZS8WS*3A EZSDWS*1A EZSTL8WS*1A EZSTLR8WS*1A EZSTL8WS*2A EZSTL8WS*3A EZSTLDWS*1A 7/16” BOLT HOLES FOR MOUNTING FASTENING UNIT TO WALL SCREWS TOP COVER UNIT CENTER LINE Fig. 4 Fig. 3 BOTTLE FILLER INSTALLATION Remove two (2) mounting screws with 5/32” allen wrench holding top cover to Bottle Filler (See FIG. 4). Remove top cover. Note do not discard mounting screws, they will be needed to reinstall top cover..
  • Page 4 EZS8WS*1A EZS8WS*2A EZS8WS*3A EZSDWS*1A EZSTL8WS*1A EZSTLR8WS*1A EZSTL8WS*2A EZSTL8WS*3A EZSTLDWS*1A BF6-BF7-BF8 PROGRAMS SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE RESETTING BOTTLE COUNT 1) To verify the software program of the control board the 1) Depress the program button for approximately 2 seconds unit will need to be shut down and restarted.
  • Page 5 EZS8WS*1A EZS8WS*2A EZS8WS*3A EZSDWS*1A EZSTL8WS*1A EZSTLR8WS*1A EZSTL8WS*2A EZSTL8WS*3A EZSTLDWS*1A BF9 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE SETTING UNIT TYPE 1) To verify the software program of the control board the 1) Depress the program button for approximately 2 seconds unit will need to be shut down and restarted.
  • Page 6: Replacement Part Kits

    IMPRESO EN LOS E.E.U.U. POUR OBTENIR DES PIÈCES, CONTACTEZ VOTRE DISTRIBUTEUR LOCAL OU COMPOSEZ LE 1.800.323.0620 IMPRIMÉ AUX É.-U. ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 98706C (Rev. D - 9/11) Page 6...
  • Page 7 EZF(S)4*1D EZF(S)8*1D, 2D, 3D EZF(S)D*1D LZF(S)8*1D, 2D, 3D LZF(S)D*1D INSTALLATION, CARE & USE MANUAL Manual de Instalación, Cuidado y Utilización Manuel d’installation/entretien/utilisation EZ & LZ Series Barrier-Free Water Coolers EZ & LZ La Barrera de la serie Liberta Agua Coolers EZ &...
  • Page 8 EZF(S)4 *1D EZF(S)8*1D, 2D, 3D EZF(S)D*1D LZF(S)8*1D, 2D, 3D LZF(S)D*1D FIG. 2 98569C (Rev. E - 11/11) Page 2 https://manual-hub.com/...
  • Page 9: Entretien

    EZF(S)4*1D EZF(S)8*1D, 2D, 3D EZF(S)D*1D LZF(S)8*1D, 2D, 3D LZF(S)D*1D HANGER BRACKETS & TRAP INSTALACIÓN DE LOS SOPORTES INSTALLATION DES SUPPORTS FIJADORES Y EL PURGADOR DE SUSPENSION ET DU SIPHON INSTALLATION Retire el soporte fijador que se encuentra 1) Retirez le support de suspension fixé au dos du 1) Remove hanger bracket fastened to back of conectado a la parte posterior del enfriador refroidisseur en retirant une (1) vis.
  • Page 10 EZF(S)4 *1D EZF(S)8*1D, 2D, 3D EZF(S)D*1D LZF(S)8*1D, 2D, 3D LZF(S)D*1D Service Instructions Lower and Upper Shroud To access the refrigeration system and plumbing connections, remove four screws from bottom of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires and water tube.
  • Page 11: Cleaning The Strainer

    EZF(S)4*1D EZF(S)8*1D, 2D, 3D EZF(S)D*1D LZF(S)8*1D, 2D, 3D LZF(S)D*1D 22, 23 & 24 Basin Estanque Bassin BUBBLER DETAIL VANDAL RESISTANT BUBBLER DETAIL DETALLE DEL GRIFO DETALLE DEL GRIFO RESISTENTE AL VANDALISMO DETAIL DU BARBOTEUR DESCRIPTION DU BARBOTEUR RESISTANT AU VANDALISME FIG.
  • Page 12 EZF(S)4 *1D EZF(S)8*1D, 2D, 3D EZF(S)D*1D LZF(S)8*1D, 2D, 3D LZF(S)D*1D When provided Cuando provisto Si Fourni FIG. 8 ® WATERSENTRY Filter Detail ® Detalle WATERSENTRY Filtro ® Description WATERSENTRY Filtrage ® WATERSENTRY FILTER PARTS LIST LISTA DE PIEZAS DEL FILTRO LISTE DES PIÈCES DU (See Fig.
  • Page 13: Switch Activation

    EZF(S)4*1D EZF(S)8*1D, 2D, 3D EZF(S)D*1D LZF(S)8*1D, 2D, 3D LZF(S)D*1D Switch Activation Note: Only side push activation is shown. Front push works the same. Detalle de la activación del interruptor ó Nota: Lateral presion activaci n que se muestran. Frontal presion es la similar. Description de l’activation de l’interrupteur ó...
  • Page 14 EZF(S)4 *1D EZF(S)8*1D, 2D, 3D EZF(S)D*1D LZF(S)8*1D, 2D, 3D LZF(S)D*1D 230V PARTS LIST/ 230V LISTA DE PIEZAS/ 230V LISTE DES PIÈCES ITEM NO. PART NO. DESCRIPTION DESCRIPCIÓN DESCRIPTION 36066C Power Cord Cable eléctrico Cordon d’Alimentation 36067C Power Cord Non-Refrigerated Cable eléctrico L/R Cordon d’Alimentation L/R 31431C Fan Motor...
  • Page 15 POUR OBTENIR DES PIÈCES, CONTACTEZ VOTRE DISTRIBUTEUR LOCAL OU COMPOSEZ LE 1.800.323.0620 PRINTED IN U.S.A. IMPRESO EN LOS E.E.U.U. ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 IMPRIMÉ AUX É.-U. Page 9 98569C (Rev. E - 11/11)

This manual is also suitable for:

Ezs8ws 2a seriesEzs8ws 3a seriesEzsdws 1a seriesEzstl8ws 1a seriesEzstlr8ws 1a seriesEzstl8ws 2a series ... Show all