SMA Solar Technology AG Table of Contents Table of Contents Notes on this Manual......6 Scope of Validity.
Page 4
Table of Contents SMA Solar Technology AG Connecting the Small Wind Turbine System (DC) ..24 5.4.1 Conditions for the DC Connection ....... . 24 5.4.2...
Page 5
Technical Data ........46 11.1 Windy Boy 1200 (WB 1200) ......46 11.2 Windy Boy 1700 (WB 1700) .
You will find further information on special topics such as designing a line circuit breaker or the description of the operating parameters in the download area at www.SMA.de/en. Refer to the user manual for detailed information on operating the inverter.
SMA Solar Technology AG Notes on this Manual 1.4 Symbols Used The following types of safety precautions and general information are used in this manual: DANGER! DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Also use appropriate protective measures to make sure that the maximum permissible input voltage of the inverter is not exceeded. SMA Solar Technology AG offers you the corresponding components, such as the Windy Boy Protection Box (overvoltage protection for wind power inverters including the rectifier).
SMA Solar Technology AG Safety 2.2 Safety Precautions DANGER! Danger to life due to high voltages in the inverter. • All work on the inverter may be carried out by qualified personnel only. CAUTION! Danger of burn injuries due to hot enclosure parts.
Safety SMA Solar Technology AG 2.3.2 Symbols on the Type Label Symbol Explanation Beware of dangerous electrical voltage. The inverter operates at high voltages. All work on the inverter may be carried out by qualified personnel only. Beware of hot surface.
SMA Solar Technology AG Unpacking 3 Unpacking 3.1 Packing List Check the delivery for completeness and for any visible external damage. Contact your dealer if anything is damaged or missing. Object Number Description Inverter Wall mounting bracket DC plug connectors (2 x positive / 2 x negative)
Installing the Device SMA Solar Technology AG 4 Installing the Device 4.1 Safety DANGER! Danger to life due to fire or explosion. Despite careful construction, electrical devices can cause fires. • Do not mount the inverter on flammable construction materials. • Do not install the inverter in areas where highly flammable materials are stored.
SMA Solar Technology AG Installing the Device 4.2 Selecting the Mounting Location Consider the following points when selecting where to install: • The installation method and location must be suitable for the inverter's weight and dimensions (see section 11 ”Technical Data” (page 46)).
Installing the Device SMA Solar Technology AG 4.3 Mounting the Inverter with Wall Mounting Bracket CAUTION! Risk of injury due to the heavy weight of the inverter! • Remember that the inverter weighs approx. 24.5 kg. • When mounting the bracket, use fastening material suitable for the material.
Page 15
SMA Solar Technology AG Installing the Device 3. Use the upper mounting clips to fit the inverter in the wall mounting bracket so that it cannot be pushed out of the wall mounting bracket from the side. 4. Use the M6x12 screws provided to fix the inverter and prevent it from being lifted out of place.
Electrical Connection SMA Solar Technology AG 5 Electrical Connection 5.1 Overview of the Connection Area 5.1.1 Exterior View The following figure shows the assignment of the individual enclosure openings on the base of the inverter. Object Description DC plug connector for connecting the small wind turbine system...
SMA Solar Technology AG Electrical Connection 5.1.2 Interior View The following illustration shows the various components and connection areas of the open inverter. Object Description Varistors Connection area and sockets for optional communication via RS485 or radio Display PE connection cable for the lid...
Electrical Connection SMA Solar Technology AG 5.2 Connection to the Public Grid (AC) 5.2.1 Conditions for the AC Connection Observe all connection conditions of the utility operator for connecting to the public grid! Cable Sizing The conductor cross-sectional area should be dimensioned so output losses do not exceed 1 % at nominal power.
Page 19
The maximum permissible rating is located in section 11 ”Technical Data” (page 46). Detailed information and examples for the rating of a line circuit breaker can be found in the Technical Information "Line Circuit Breaker" in the SMA Solar Technology AG download area at www.SMA.de/en. DANGER! Danger to life due to fire.
2. Check that the grid voltage is within the admissible voltage range. The exact operating range of the inverter is specified in the operating parameters. The corresponding document is available in the download area at www.SMA.de/en in the category "Technical Description" of the respective inverter.
Page 21
SMA Solar Technology AG Electrical Connection Size used Procedure PG13.5 • Push the sealing ring into the fastening case. • Pass the pressure screw PG13.5 and the fastening case including the sealing ring over the AC cable. • Pass the threaded sleeve over the AC cable.
Page 22
Electrical Connection SMA Solar Technology AG 13. Screw the threaded sleeve tightly onto the socket element. 14. Tighten the pressure screw or cable gland tightly onto the threaded sleeve. Size used Procedure PG13.5 The fastening case along with the sealing ring is pressed into the threaded sleeve and can no longer be seen.
SMA Solar Technology AG Electrical Connection 5.3 Setting the Display Language You can set the language of the display using the switches on the underside of the display assemblies inside the inverter. Procedure 1. Open the inverter as described in section 7.2 ”Opening the Inverter” (page 33).
Electrical Connection SMA Solar Technology AG 5.4 Connecting the Small Wind Turbine System (DC) 5.4.1 Conditions for the DC Connection • The connection cables of the small wind turbine system must be equipped with plug connectors. You will find the necessary DC plug connectors for the DC connection in the delivery.
SMA Solar Technology AG Electrical Connection 5.4.2 Assembling the DC Plug Connector The connection cables of the small wind turbine system must be equipped with the DC plug connectors provided for connecting the inverter. To assemble the DC plug connectors, proceed as follows: Make sure the plug connectors have the correct polarity.
Page 26
Electrical Connection SMA Solar Technology AG Result Action ☑ If the conductor is not visible in the hollow • Loosen the clamping bracket with the help cavity of the clamp, the cable is not in the of a screwdriver. correct position.
SMA Solar Technology AG Electrical Connection 5.4.3 Opening the DC Plug Connector 1. Screw the threaded joint off. 2. To release the plug connector, slot a screw driver into the side catch mechanism and lever out. 3. Carefully pull apart the DC plug connector.
Electrical Connection SMA Solar Technology AG 5.4.4 Connecting the Small Wind Turbine System (DC) DANGER! Danger to life due to high voltages in the inverter. • Before connecting the small wind turbine system, ensure that the small wind turbine system is stopped.
To change the grid-relevant parameters, you need a personal access code, the so-called SMA grid guard code. The application form for the personal access code can be found in the download area at www.SMA.de/en in the category "Data Sheet" of the respective inverter.
• KI-Wind-Reg • T-Stop A description of the operating parameter is available in the download area at www.SMA.de/en in the category "Technical Description" of the respective inverter. The inverter regulates its output power according to the generator voltage. The following illustration shows the function of a typical polynomial characteristic curve of a WB 1200 / WB 1700.
SMA Solar Technology AG Commissioning 6 Commissioning 6.1 Commissioning the Inverter 1. Check the following requirements before commissioning: – Correct mounting and correct connection of the inverter – The enclosure lid is securely closed – The line circuit breaker is laid out correctly –...
Commissioning SMA Solar Technology AG 6.2 Operating Modes of the Inverter Startup Procedure If the inverter has enough voltage and power, the startup process is displayed by means of simultaneous lighting of the three LEDs on the inverter. As soon as the DC input voltage defined in the parameter "U Start"...
SMA Solar Technology AG Opening and Closing 7 Opening and Closing 7.1 Safety DANGER! Electric shock due to high voltage in the inverter. This can result in death or serious burns. Pay attention to the following points before opening the inverter: • Ensure that there are no hazardous voltages present on the AC side •...
Page 34
Opening and Closing SMA Solar Technology AG 3. Release all DC plug connectors with the help of a screwdriver: – Insert a screwdriver into one of the side slits (1). – Lever the screwdriver upward (2) and pull out the plug connector (3).
SMA Solar Technology AG Opening and Closing 7.3 Closing the Inverter 1. Reconnect the protective conductor (PE) connection to the enclosure lid. 2. Secure the enclosure lid of the inverter by evenly tightening the 4 lid screws. 3. Check the DC plug connectors for correct polarity and connect them to the inverter.
Maintenance and Cleaning SMA Solar Technology AG 8 Maintenance and Cleaning Check for proper inverter operation at regular intervals. Impurities such as dust can limit the heat dissipation of the inverter. Also check the inverters and the cables for visible external damage.
You will find descriptions of the display messages during operation, status messages and measuring channels in the enclosed user manual. Do not try to carry out repairs other than those described here. Instead, use the SMA Solar Technology AG 24-hour replacement service (the inverter will be ready for dispatch within 24 hours and sent to a forwarding agency) and repair service.
• If the grid voltage is continually within the acceptable range, and this error is still displayed, contact the SMA Serviceline. Bfr-Srr Internal measurement comparison disturbance or hardware defect. Corrective measures • Contact the SMA Serviceline if this disturbance occurs frequently. WB12_17-IEN101131 Installation Guide...
Page 39
• Check the system design and grid conditions. K1-Close Fault during relay test. Corrective measures K1-Open • Contact the SMA Serviceline if this problem occurs frequently or several times in succession. MSD-FAC Internal measurement comparison disturbance or hardware defect. Corrective measures MSD-UAC •...
Page 40
• Check the system for ground faults as described in section 9.3.1 ”Checking the Small Wind Turbine System for a Ground Fault” (page 42). The inverter's firmware is faulty. Corrective measures • Contact the SMA Serviceline if this disturbance occurs frequently. Shut-Down Temporary inverter fault. Corrective measures • Contact the SMA Serviceline.
Page 41
5.4.4 ”Connecting the Small Wind Turbine System (DC)” (page 28). If the message occurs again, disconnect the inverter again and contact the SMA Serviceline. Watchdog Internal program run fault. Corrective measures Watchdog-Srr • Contact the SMA Serviceline if this disturbance occurs frequently. Installation Guide WB12_17-IEN101131...
Failure Search SMA Solar Technology AG 9.3 Red LED is Glowing Continuously Should the red LED on the inverter illuminate continuously during operation, either there has been a ground fault in the system or at least one of the varistors inside the inverter is defective.
B and Result Action ☑ There is a conducting There is probably a different fault in the inverter. connection. 1. Close the inverter as described in section 7.3 ”Closing the Inverter” (page 35). 2. Contact the SMA Serviceline. Installation Guide WB12_17-IEN101131...
Page 44
The varistors are specially manufactured for use in the inverter and are not commercially available. You must order replacement varistors directly from SMA Solar Technology AG (see section 12 ”Accessories” (page 52)). • To replace the varistors, proceed to step 3.
Dispose of the inverter at the end of its service life in accordance with the disposal regulations for electronic waste which apply at the installation site at that time. Alternatively, send it back to SMA Solar Technology AG with shipping paid by sender, and labeled "ZUR ENTSORGUNG"...
Technical Data SMA Solar Technology AG 11 Technical Data 11.1 Windy Boy 1200 (WB 1200) DC Input Turbine control Polynomial characteristic curve Nominal power 1,200 W DC, nom Maximum power 1,320 W DC, max Recommended generator power at 2,500 1,050 W DC, 2500...
SMA Solar Technology AG Technical Data AC Output Nominal power 1,200 W AC, nom Maximum power 1,200 W AC, max Nominal current 5.2 A AC, nom Maximum output current 6.1 A AC max Maximum permissible rating 16 A Harmonic distortion of the grid current at <...
Technical Data SMA Solar Technology AG Climatic Conditions Operating temperature range − 25 °C ... +60 °C Relative air humidity (admissible) 0 % ... 100 % Maximum operating altitude above mean sea 2,000 m level General Data Protection rating IP65...
SMA Solar Technology AG Technical Data 11.2 Windy Boy 1700 (WB 1700) DC Input Turbine control Polynomial characteristic curve Nominal power 1,700 W DC, nom Maximum power 1,850 W DC, max Recommended generator power at 2,500 1,400 W DC, 2500 full-load hours per year...
Page 50
Technical Data SMA Solar Technology AG AC Output Nominal power 1,550 W AC, nom Maximum power 1,700 W AC, max Nominal current 6.7 A AC, nom Maximum output current 8,6 A AC max Maximum permissible rating 16 A Harmonic distortion of the grid current at <...
Page 51
SMA Solar Technology AG Technical Data Climatic Conditions Operating temperature range − 25 °C … +60 °C Relative air humidity (admissible) 0 % … 100 % Maximum operating altitude above mean sea 2,000 m level General Data Protection rating IP65...
SMA Solar Technology AG 12 Accessories You will find the corresponding accessories and replacement parts for your inverter in the following overview. If required, you can order these from SMA Solar Technology AG or your dealer. Description Brief description SMA order...
SMA Solar Technology AG Contact 13 Contact If you have technical problems concerning our products, contact the SMA Serviceline. We require the following information in order to provide you with the necessary assistance: • Inverter type • Inverter serial number • Type of connected small wind turbine system •...
Page 54
Contact SMA Solar Technology AG WB12_17-IEN101131 Installation Guide...
The use of supplied software produced by SMA Solar Technology AG is subject to the following conditions: • SMA Solar Technology AG rejects any liability for direct or indirect damages arising from the use of software developed by SMA Solar Technology AG. This also applies to the provision or non-provision of support activities.
Need help?
Do you have a question about the WINDY BOY 1200 and is the answer not in the manual?
Questions and answers