Wall Monosplit WARRIORS DC Inverter Wall Monosplit WARRIORS DC Inverter Table of Contents n PRODUCT LINEUP & DATA TABLES ....................3 1. PRODUCT DATA ..........................[1]-1 1.1 MODEL REFERENCE ........................[1]-1 1.2 GENERAL SPECIFICATIONS ..................... [1]-2 1.3 DIMENSIONAL DRAWINGS ...................... [1]-6 1.4 CENTRE OF GRAVITY .......................
Wall Monosplit WARRIORS DC Inverter n PRODUCT LINEUP & DATA TABLES WARRIORS DC INVERTER in cooling in heating 21.5dB maximum silence in Silent mode MONOSPLIT WALL AIR CONDITIONING UNIT OPERATION -15~50 Warriors is a sober and elegant air conditioning unit that can be adapted to any type of décor.
Page 4
Wall Monosplit WARRIORS DC Inverter RESIDENTIAL AIR CONDITIONERS WITH R32 REFRIGERANT WARRIORS DC INVERTER Wall HKEMS 264-354 Z -15~50 in cooling High density filter Refrigerant leak detection Automatic horizontal Remote control swinging of air outlet flaps included as -20~30 in heating Self Cleaning Anti-freeze function 8 standard...
Wall Monosplit WARRIORS DC Inverter: 1. Product Data 1. PRODUCT DATA 1.1 MODEL REFERENCE Refer to the following table to determine the specific Indoor and Outdoor Unit model of your purchased equipment. Indoor Unit Model Outdoor Unit Model Capacity (Btu/h) Power Supply HKEMS 264 Z HCNMX 264 Z...
Wall Monosplit WARRIORS DC Inverter: 1. Product Data 1.2 GENERAL SPECIFICATIONS Indoor Model HKEMS 264 Z Outdoor Model HCNMX 264 Z 220~240-1-50 Power supply V-Ph-Hz 2150 Max. input consumption Max. current KSK103D32UEZ31 Model Type ROTARY GMCC Brand 2020/3245 ±3% Capacity 332/850 ±3% Input 2.42/5.70 ±3%...
Page 7
Wall Monosplit WARRIORS DC Inverter: 1. Product Data Indoor Model HKEMS 264 Z Outdoor Model HCNMX 264 Z Outdoor sound pressure level dB(A) Outdoor sound power level dB(A) Dimension (W × × × × Outdoor unit Packing (W × × ×...
Page 8
Wall Monosplit WARRIORS DC Inverter: 1. Product Data Indoor Model HKEMS 354 Z Outdoor Model HCNMX 354 Z 220~240-1-50 Power supply V-Ph-Hz Max. input consumption 2150 Max. current Model KSK103D32UEZ31 Type ROTARY Brand GMCC Capacity 2020/3245 ±3% 332/850 ±3% Input 2.42/5.70 ±3% Compressor Rated current (RLA)
Page 9
Wall Monosplit WARRIORS DC Inverter: 1. Product Data Indoor Model HKEMS 354 Z Outdoor Model HCNMX 354 Z 54.5 Outdoor sound pressure level dB(A) Outdoor sound power level dB(A) Dimension (W × × × × Outdoor unit Packing (W × ×...
Wall Monosplit WARRIORS DC Inverter: 1. Product Data 1.3 DIMENSIONAL DRAWINGS 1.3.1 Indoor Units Unit: mm W (mm) D (mm) H (mm) Model HKEMS 264 Z HKEMS 354 Z [1]-6...
Wall Monosplit WARRIORS DC Inverter: 1. Product Data 1.5 ELECTRICAL WIRING DIAGRAMS 1.5.1 Indoor Units Abbreviation Paraphrase Yellow-Green Conductor Positive and Negative Ion Generator Capacitor PLASMA Electronic Dust Collector LIVE NEUTRAL Indoor Room Temperature Coil Temperature of Indoor Heat Exchanger [1]-9...
Page 14
Wall Monosplit WARRIORS DC Inverter: 1. Product Data Models HKEMS 264 Z, HKEMS 354 Z [1]-10...
Page 15
Wall Monosplit WARRIORS DC Inverter: 1. Product Data 1.5.2 Outdoor Units Abbreviation Paraphrase Gas Valve Assembly / 4-WAY VALVE 4-WAY Alternating Current FAN AC-FAN Direct Current FAN DC-FAN Compressor COMP [1]-11...
Page 16
Wall Monosplit WARRIORS DC Inverter: 1. Product Data Models HCNMX 264 Z, HCNMX 354 Z OPTIONAL AC-Fan OPTIONAL CN 16 CN 2 CN 1 CN 3 CN 50 Black [1]-12...
Wall Monosplit WARRIORS DC Inverter: 1. Product Data 1.7 CAPACITY TABLES 1.7.1 Cooling HKEMS 264 Z - HCNMX 264 Z Indoor temp. Indoor Outdoor 16.0 18.0 19.0 22.0 WB (°C) airflow temp. DB (°C) Indoor temp. 23.0 25.0 27.0 30.0 23.0 25.0 27.0...
Page 19
Wall Monosplit WARRIORS DC Inverter: 1. Product Data HKEMS 264 Z - HCNMX 264 Z Indoor temp. Indoor Outdoor 16.0 18.0 19.0 22.0 WB (°C) airflow temp. DB (°C) Indoor temp. 23.0 25.0 27.0 30.0 23.0 25.0 27.0 30.0 23.0 25.0 27.0 30.0...
Page 20
Wall Monosplit WARRIORS DC Inverter: 1. Product Data HKEMS 354 Z - HCNMX 354 Z Indoor temp. Indoor Outdoor 16.0 18.0 19.0 22.0 WB (°C) airflow temp. DB (°C) Indoor temp. 23.0 25.0 27.0 30.0 23.0 25.0 27.0 30.0 23.0 25.0 27.0 30.0...
Page 21
Wall Monosplit WARRIORS DC Inverter: 1. Product Data HKEMS 354 Z - HCNMX 354 Z Indoor temp. Indoor Outdoor 16.0 18.0 19.0 22.0 WB (°C) airflow temp. Indoor temp. DB (°C) 23.0 25.0 27.0 30.0 23.0 25.0 27.0 30.0 23.0 25.0 27.0 30.0...
Page 22
Wall Monosplit WARRIORS DC Inverter: 1. Product Data 1.7.2 Heating HKEMS 264 Z - HCNMX 264 Z [SI_Unit] HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE Indoor TC: TOTAL CAPACITY IN KILOWATTS (KW) PI: TOTAL POWER IN KILOWATTS (KW) Outdoor airflow temp.
Page 23
Wall Monosplit WARRIORS DC Inverter: 1. Product Data HKEMS 354 Z - HCNMX 354 Z [SI_Unit] HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE Indoor TC: TOTAL CAPACITY IN KILOWATTS (KW) PI: TOTAL POWER IN KILOWATTS (KW) Outdoor airflow temp. Indoor Temp. Conditions (DB °C ) Indoor Temp.
Wall Monosplit WARRIORS DC Inverter: 1. Product Data 1.8 NOISE CRITERION CURVES 1.8.1 Indoor Units 0.8m Microphone Notes: - Sound is measured at 1.0m away from the center of the unit. - Data is valid at free field condition. - Data is valid at nominal operation conditions. - Reference acoustic pressure 0dB=20µPa.
Page 25
Wall Monosplit WARRIORS DC Inverter: 1. Product Data Model HKEMS 354 Z [1]-21...
Page 26
Wall Monosplit WARRIORS DC Inverter: 1. Product Data 1.8.2 Outdoor Units Microphone Note: H=0.5 × Height of Outdoor Unit Notes: - Sound is measured at 1.0m away from the center of the unit. - Data is valid at free field condition. - Data is valid at nominal operation conditions.
Page 27
Wall Monosplit WARRIORS DC Inverter: 1. Product Data Model HCNMX 354 Z [1]-23...
Wall Monosplit WARRIORS DC Inverter: 1. Product Data 1.9 ELECTRICAL CHARACTERISTICS Indoor Unit Power Supply Models Phase Voltage HKEMS 264 Z 0.29 220-240 HKEMS 354 Z 0.29 Outdoor Unit Power Supply Compressor Models Phase Voltage HCNMX 264 Z 8.18 13.9 0.76 220-240 HCNMX 354 Z...
Wall Monosplit WARRIORS DC Inverter: 2. Control Functions 2. CONTROL FUNCTIONS 2.1 OPERATION MODES AND FUNCTIONS 2.1.1 Display Function Unit display functions: Follow the display type of your purchased product: fresh defrost run timer fresh defrost run timer fresh defrost run timer Display Function...
Wall Monosplit WARRIORS DC Inverter: 2. Control Functions 2.1.2 Abbreviations Unit element abbreviations: Abbreviation Element Indoor room temperature Coil temperature of evaporator Coil temperature of condenser Outdoor ambient temperature Compressor discharge temperature 2.1.3 Safety Features Compressor three-minute delay at restart Compressor functions are delayed for up to 1 minute upon the first startup of the unit, and are delayed for up to 3 minutes upon subsequent unit restarts.
Wall Monosplit WARRIORS DC Inverter: 2. Control Functions • When T1-Ts > ∆T5 + 3°C, the compressor continues operation. • When the AC is operating in mute mode, the compressor operates at a low frequency. • When the current exceeds the preset value, the current protection function activates and the compressor ceases operation.
Wall Monosplit WARRIORS DC Inverter: 2. Control Functions 2.1.6.3 Outdoor Fan Control: • The Outdoor Unit will be run at different fan speed according to T4 and compressor frequency. • For different outdoor units, the fan speeds are different. 2.1.6.4 Defrosting mode •...
Wall Monosplit WARRIORS DC Inverter: 2. Control Functions - Quit normal defrosting - Turn off by remote controller. - Press AUTO/COOL button continuously for 5s again. 2.1.10 Sleep function • The sleep function is available in cooling, heating, or auto mode. •...
Wall Monosplit WARRIORS DC Inverter: 2. Control Functions 2.2 INFRARED REMOTE CONTROLLER 2.2.1 IR Remote Controller RG-57A6-BGEF Remote Controller Specifications: Model RG-57A6-BGEF Rated Voltage 3.0V (Dry batteries R03/LR03 × 2) Reaching Distance 8m (when using 3.0 voltage, it gets 11m) Environment Temperature Range -5°C~60°C Remote Controller Buttons' Outline...
Page 36
Wall Monosplit WARRIORS DC Inverter: 2. Control Functions ON/OFF Button. To start/stop air conditioner’s operation. MODE Setting Button. To select operation mode of the air conditioner: AUTO / COOL / HEAT / FAN / DRY. FAN Speed Button. To select fan speed: AUTO / LOW / MEDIUM / HIGH. SLEEP Function Button.
Page 37
Wall Monosplit WARRIORS DC Inverter: 2. Control Functions LCD Display (IR Remote Controller) Outline All information are simultaneously displayed when the remote controller is powered up. Operation Mode display: AUTO COOL HEAT Displayed when data are transmitted. Displayed when remote controller is ON. Battery level display (low battery detection).
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation 3.2 OUTDOOR UNIT LOCATION SELECTION 3.2.1 For unit location selection, you can also refer to the Installation Manual. 3.2.2 Do not install the Unit in the following locations: • Where oil drilling or fracking is taking place. •...
Page 41
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation • Do not install the rows of series like following figure. 3.2.5 If the Outdoor Unit is exposed to heavy wind • Install unit so that air outlet fan is at a 90° angle to the direction of the wind. If needed, build a barrier in front of the unit to protect it from extremely heavy winds.
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation 3.3 INDOOR UNIT INSTALLATION 3.3.1 Service spaces for Indoor Unit 12cm or more 12cm or more 3.3.2 Attach mounting plate to wall • The mounting plate is the device on which you will mount the Indoor Unit. 1.
Page 43
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation Models HKEMS 264 Z 398mm 233.1mm 146.5mm Indoor Unit Outline Right rear wall Left rear wall hole: Ø65mm hole (Ø65mm) 115.6mm 117.5mm 101.6mm 45mm 715mm Model HKEMS 354 Z 398mm 241mm 28.5mm Indoor Unit Outline Right rear wall Left rear wall...
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation 3.3.3 Drill wall hole for connective piping You must drill a hole in the wall for refrigerant piping, the drainage pipe, and the signal cable that will connect the Indoor and Outdoor Unit. 1.
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation Be extremely careful not to dent or damage the piping while bending them away from the unit. Any dents in the piping will affect the unit’s performance. 3.3.5 Connect drain hose By default, the drain hose is attached to the left hand side of unit (when you’re facing the back of the unit). •...
Page 46
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation 3.3.6 Connect signal and power cable 3.3.6.1 Before performing electrical work, read these regulations 1. All wiring must comply with local and national electrical codes, and must be installed by a licensed Electrician. 2.
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation 4. Unscrew the cable clamp below the terminal block and place it to the side. 5. Facing the back of the unit, remove the plastic panel on the bottom left-hand side. 6. Feed the signal wire through this slot, from the back of the unit to the front. 7.
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation 3.3.8 Mount Indoor Unit 3.3.8.1 If you installed new connective piping to the Outdoor Unit, do the following: 1. If you have already passed the refrigerant piping through the hole in the wall, proceed to “Prepare refrigerant piping”.
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation 3.4 OUTDOOR UNIT INSTALLATION 3.4.1 Service spaces for Outdoor Unit (Wall or obstacle) More than 30cm More than 60cm More than 30cm Maintain channel More than 60cm Air inlet Air outlet More than 200cm 3.4.2 Bolts pitch Capacity (kBtu/h) A (mm)
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation Caution: Since the gravity center of the unit is not at its physical center, so please be careful when lifting it with a sling. Never hold the inlet of the Outdoor Unit to prevent it from deforming. Do not touch the fan with hands or other objects.
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation 3.5 REFRIGERANT PIPE INSTALLATION 3.5.1 Maximum length and drop height Ensure that the length of the refrigerant pipe, the number of bends, and the drop height between the Indoor and Outdoor Unit meet the requirements shown in the following table. Capacity (kBtu/h) Max.
Page 52
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation 3.5.2 The procedure of connecting pipes 1. Choose the pipe size according to the specification table. 2. Confirm the cross way of the pipes. 3. Measure the necessary pipe length. 4. Cut the selected pipe with pipe cutter. •...
Page 53
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation Flare dimension “B” (mm) Flare shape Pipe Diameter Min. Max. 1/4” (6.35) 90°± 4 3/8” (9.52) 13.2 13.5 1/2” (12.7) 16.2 16.5 R0.4~0.8 5/8” (15.88) 19.2 19.7 3/4” (19.05) 23.2 23.7 !!! WARNING !!!: For safety reasons refrigerant piping connections both on the Indoor Unit side and on the Outdoor Unit side must be conducted in the outdoor environment, as R32 refrigerant is a potentially flammable gas.
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation 3.6 VACUUM DRYING AND REFRIGERANT LEAKAGE CHECKING 3.6.1 Purpose of vacuum drying • Eliminating moisture in system to prevent the phenomena of ice-blockage and copper oxidation. Ice-blockage shall cause abnormal operation of system, while copper oxide shall damage compressor. •...
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation 3.7 ADDITIONAL REFRIGERANT CHARGE • After the vacuum drying process was carried out, the additional refrigerant charge process may need to be perfor- med. • The Outdoor Unit is factory charged with refrigerant. The additional refrigerant charge volume is decided by the diameter and length of the liquid pipe between Indoor and Outdoor Unit.
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation 3.8 ELECTRICAL LEAKS AND GAS LEAKAGE CHECKS 3.8.1 Electrical Safety Checks After installation, confirm that all electrical wiring is installed in accordance with local and national Regulations, and according to the Installation Instructions. 3.8.1.1 Before test run •...
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation 3.9 TEST OPERATION 3.9.1 Before Test Run Only perform Test Run after you have completed the following steps: • Electrical Safety Checks. Confirm that the unit’s electrical system is safe and operating properly. •...
Page 58
Wall Monosplit WARRIORS DC Inverter: 3. Units’ Installation 3.9.3 If indoor ambient temperature is below 17°C You can’t use the remote controller to turn on the COOL function when the ambient temperature is below 17°C. In this instance, you can use the “MANUAL CONTROL” button to test the COOL function. 1.
Page 61
Wall Monosplit WARRIORS DC Inverter HOKKAIDO is a brand of TERMAL SALES TERMAL SALES S.r.l. Via della Salute 14 Tel. +39 051 4133 111 40132 Bologna Italy w w w. h o k k a i d o . i t Due to on-going technological development of the products by the manufacturer, we reserve the right to vary the technical specifications at any time without notice.