Two-Reader Module
PW7K1R2/PW7K1R2B
Install Guide

Advertisement

loading
Need help?

Need help?

Do you have a question about the Pro-Watch 7000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Honeywell Pro-Watch 7000

  • Page 1 Pro-Watch 7000 Two-Reader Module PW7K1R2/PW7K1R2B Install Guide...
  • Page 2 All product and brand names are the service marks, trademarks, registered trademarks, or registered service marks of their respective owners. Printed in the United States of America. Honeywell reserves the right to change any information in this document at any time without prior notice.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Notices............................... iii Warnings and Cautions......................iii Compliance ..........................v Conformité..........................vi Avertissements et mises en garde .................. vii Disclaimer..........................ix Limited Warranty ........................ix Confidentiality ...........................x Compliance ..........................xi CE and WEEE Marking ......................xi Unpacking Procedure ......................xi Shipping Instructions ......................
  • Page 4 Installing the Module .........................27 Appendix A - Programming Sheet............... 27 PW-7000 Two-Reader Module Installation Guide, Document 800-25676V2...
  • Page 5: Notices

    DO NOT ACCEPT VERBAL APPROVALS, BECAUSE THEY ARE NOT VALID. Honeywell never recommends using the PW-7000 or related products for use as a primary warning or monitoring system. Primary warning or monitoring systems should always meet local fire and safety code requirements.
  • Page 6 Note: See the Remote Enclosure Installation manuals for PW5K2ENC1/PW5K2ENC2 or PW5K1ENC3 for installation instructions. Warning: EARTH GROUND all enclosures for proper installation. Warning: The S-4 Suppressor Kit must be installed with every electrical switching device connected through a relay contact, without regard to polarity. One S-4 is installed across the relay at the panel and the other is installed within 18 inches of the electrical switching device.
  • Page 7: Compliance

    Inc. Copyright laws of the United States protect all information in this document or in the software product itself. Note: Any use of this product is subject to the terms and acceptance of the Honeywell, Inc. Software Agreement. Please request a copy from Honeywell, Inc., and review the agreement carefully.
  • Page 8: Conformité

    The Model PW7K1R2B/PRO42R2B Reader Board does not employ configuration mode. Duress Function not applicable as only verified Grade Level 1 under ULC 60839- 11-1, functions with the separately Listed Honeywell OP40 Card Reader, which does not employ a keypad. Conformité...
  • Page 9: Avertissements Et Mises En Garde

    La fonction de contrainte n'est pas applicable car elle n'a été vérifiée que pour les fonctions de niveau 1 avec le lecteur de carte OP40 d'Honeywell répertorié séparé- ment, qui n'utilise pas de clavier. Avertissements et mises en garde Les méthodes de câblage doivent être conformes au Code national de l'électricité...
  • Page 10 Remarque: Pour les instructions d'installation, voir les manuels d'installation des boîtiers distants pour PW5K2ENC1/PW5K2ENC2 ou PW5K1ENC3. Avertissement: METTRE À LA TERRE tous les boîtiers pour une installation correcte. Avertissement: Le kit de suppression S-4 doit être installé avec chaque dispositif de commutation électrique connecté...
  • Page 11: Disclaimer

    Honeywell, Inc. Les lois sur les droits d'auteur des États-Unis protègent toutes les informations contenues dans ce document ou dans le produit logiciel lui-même.
  • Page 12: Confidentiality

    Confidentiality All software, drawings, diagrams, specifications, catalogs, literature, manuals and other materials furnished by Honeywell relating to the design, use and service of the Products shall remain confidential and shall constitute proprietary rights of Honeywell and Customer agrees to treat such information as confidential. Cus-...
  • Page 13: Compliance

    For any additional information regarding the compliance of this product to any EU-specific requirements, please contact: Honeywell Security & Communications Honeywell Security - Quality Assurance Dept., Newhouse Industrial Estate Mother- well Lanarkshire ML1 5SB Scotland United Kingdom Tel: +44)0) 1698 738200 Email: UK64Sales@Honeywell.com...
  • Page 14: Shipping Instructions

    If shipping caused damage to the unit, a claim must be filed with the commercial carrier. If any other defect is apparent, call for a return authorization. Shipping Instructions To ship equipment back to Honeywell, Inc.: Step 1. Contact the customer service department at 800-323-4576 before returning equipment. When you call please have available: •...
  • Page 15: Chapter 1 - Reader Module

    CHAPTER READER MODULE Description The PW-7000Two-Reader Module provides support for up to two access control doors by providing connections for Wiegand or Clock/Data type readers, super- vised inputs, and relay outputs. You can either mount the board in a rack or open flat.
  • Page 16: Specifications

    Specifications The Two-Reader Module is for use in low voltage, class 2 circuits only. Primary power: • 12VDC + 10%, 650mA maximum with 5VDC, or 12 VDC readers, 300 mA max. excluding readers Relay contacts: • Relays 0 and 2 outputs, Form-C, Max 5A @ 30VDC, Min ~0A @30VDC, resistive •...
  • Page 17 Wire requirements: Power 1 twisted pair, 18AWG 24AWG, 4,000 feet (1,200 m) max., twisted pair with shield RS-485 (120 ohms, 23pf) (Belden 9842 or equiv.) Inputs 1 twisted pair per input, 30 ohms max. Outputs As required for the load 6 conductors, 18AWG, 500 feet (150m) max.
  • Page 18: Setup

    Setup Setting Jumpers Table 1: Jumper Settings Jumper Setting Default Selected Port 1 RS-485 EOL terminator is not active Port 1 RS-485 EOL terminator is active Reader 0 Power Terminal provides 5 VDC Reader 0 Power Terminal provides 12 VDC Reader 1 Power Terminal provides 5 VDC Reader 1 Power Terminal provides 12 VDC Setting DIP Switches...
  • Page 19: Led Operation

    Selection ADDRESS 25 ADDRESS 26 ADDRESS 27 ADDRESS 28 ADDRESS 29 ADDRESS 30 ADDRESS 31 Reserved 9,600 BPS 19,200 BPS 38,400 BPS* Not Used* * = Default LED Operation The Two-Reader Module uses two onboard LEDs (D1 and D2) to provide status information during the power-up sequence as well as during normal operation.
  • Page 20: Power

    Table 4: Additional PW7000 Two-Reader Module LEDs LED number Description Reader 0 activity Reader 1 activity Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Tamper Power Relay 0 status Relay 3 status Relay 2 status Relay 4 status Relay 1 status...
  • Page 21: Wiring

    Step 1. TR+ is the plus side of the transmit and receive differential signal. Step 2. TR- is the negative side of the transmit and receive differential signal. Step 3. GND is the signal ground.The wiring for this signal is required and NOT optional.
  • Page 22 Figure 1: PW-7000 Two-Reader Module (PW7K1R2) Wiring: Connectors TB1-TB7 Short TWO READER BOARD Door Status BLACK together* Switch IN4 COMMON WHITE Egress GREEN Push-Button Switch IN5 COMMON Typical Connection IN0 COMMON IN1 COMMON RELAY0 NO RELAY0 C Door Lock Suppressor RELAY0 NC BLACK RELAY1 NO...
  • Page 23 Figure 2: PW-7000 Two-Reader Module (PW7K1R2) Wiring: Connectors TB1, TB7-TB9 Tamper Switch (In CLOSE TWO READER BOARD position when +12VDC Power Cabinet Door is Supply Closed) C - No Charging N/C - No Charging N/C - Low Battery IN6 Common C - Low Battery IN7 Common Relay 4 NC...
  • Page 24 Figure 3: PW-7000 Two-Reader Module (PW7K1R2B) Wiring: Connectors TB1-TB7 Door Status Switch BLACK WHITE Egress GREEN Push-Button TWO READER BOARD Switch IN4 COMMON Typical Connection Short N5 COMMON togethe IN0 COMMON IN1 COMMON RELAY0 NO Door Lock Suppressor RELAY0 C RELAY0 NC RELAY1 NO Separate...
  • Page 25 Figure 4: PW-7000 Two-Reader Module (PW7K1R2B) Wiring: Connector TB1, TB7-TB9 Tamper Switch (In CLOSE position when Cabinet Door is Closed) TWO READER BOARD +12VDC Power Supply C - No Charging N/C - No Charging N/C - Low Battery IN6 Common C - Low Battery IN7 Common Relay 4 NC...
  • Page 26: Reader Wiring

    Input on supervised F/2F readers may be unsupervised or supervised (supervised shown). Reader Wiring The following Honeywell reader module numbers have been approved by UL for use with the PW7K1R2/PW7K1R2B: OS20TOSDP, OS20KTOSDP, OS40TOSDP, OS40KTOSDP. Each reader port supports a reader with TTL interface. Power to the reader is selectable as 5VDC or 12VDC (pass-through).
  • Page 27: Input Wiring

    Table 5: Settings for Wiring to a Reader Port Terminal Typical Wire Color Wiegand Reader Clock/Data Reader OSDP Reader Power (5 or 12 Vdc) Power (5 or 12 Vdc) Power (12 VDC) Brown LED control LED control Yellow Beeper Control Beeper Control White Data 1 Signal...
  • Page 28: Control Output Wiring

    Inputs TMP and PFL are typically used for monitoring cabinet tamper and power failure respectively. These two inputs are not supervised and are not accessible when the board is rack-mounted. These inputs were primarily provided for the case when this board is mounted remotely and cannot take advantage of the tamper and power fail detect inputs on the controller board.
  • Page 29: Mounting Options

    Mounting Options This board can be mounted on-edge in the rack-mount enclosure provided by Honeywell or it can be mounted flat against any surface using standoffs under the mounting holes provided in each of the four corners of this board.
  • Page 30 This page is intentionally left blank. PW-7000 Two-Reader Module Installation Guide, Document 800-25676V2...
  • Page 31: Programming Sheet

    APPENDIX PROGRAMMING SHEET PW-7000 2-Reader Input Module Programming Sheets: Project Name Location / Country Host IC Board Board Description PW Panel RS485 Port Board Address Location Floor Cabinet Location Tamper Input Connected Powerfail Shunted Termination Jumper J1 Not Active RS485 Port + Power Connector Connected Cable # Cable Destination...
  • Page 32 Door 1 Input / Output Connected Cable # Cable Destination Conductor Color Input 0 Com Pin #2 Input 1 Pin #3 Input 1 Com Pin #4 Relay 0 No Pin #5 Relay 0 Com Pin #6 Relay 0 NC Pin #7 Relay 1 No Pin #8 Relay 1 Com...
  • Page 33 Inputs 6 and 7 Connected Cable # Cable Destination Conductor Color Input 6 Pin #1 Input 6 Com Pin #2 Input 7 Pin #3 Input 7 Com Pin #4 Inputs 4 and 5 Connected Cable # Cable Destination Conductor Color Relay 4 NC Pin #1 Relay 4 Com...
  • Page 34 This page is intentionally left blank PW-7000 Two-Reader Module Installation Guide, Document 800-25676V2...
  • Page 36 Honeywell Building Technologies Building 5 Carlton Park King Edward Avenue Narborough Leicester LE19-OAL United Kingdom Copyright©2022 Honeywell International Inc. www.security.honeywell.com/uk/ Technical Support Self-Service | Customer Portal https://myhoneywellbuildingsuniversity.com/training/support/ ™ YouTube | Honeywell Help and Support https://www.youtube.com/channel/UCBEL6ouNV_LN5lEpYRujMTg/featured Document 800-25676V2 06/2023...

This manual is also suitable for:

Pw7k1r2Pw7k1r2b