FMS BMGZ710 Operating Manual

Robust evaluation unit for conveyor belt scales, with optional profnet interface
Hide thumbs Also See for BMGZ710:

Advertisement

Quick Links

Operating Manual BMGZ710
and BMGZ710.PNET
Robust evaluation unit for conveyor belt scales, with
optional PROFNET interface
Document Version
3.20
Published / Author
01/2024
NS
Firmware Version BMGZ710
2.35
Firmware Version BMGZ710.PNET
2.35
Diese Bedienungsanleitung ist auch in Deutsch erhältlich.
Bitte kontaktieren Sie Ihre nächstgelegene FMS Vertretung.
© by FMS Force Measuring Systems AG, CH-8154 Oberglatt – All rights reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BMGZ710 and is the answer not in the manual?

Questions and answers

Summary of Contents for FMS BMGZ710

  • Page 1 3.20 Published / Author 01/2024 Firmware Version BMGZ710 2.35 Firmware Version BMGZ710.PNET 2.35 Diese Bedienungsanleitung ist auch in Deutsch erhältlich. Bitte kontaktieren Sie Ihre nächstgelegene FMS Vertretung. © by FMS Force Measuring Systems AG, CH-8154 Oberglatt – All rights reserved.
  • Page 2: Table Of Contents

    Scope of delivery ..........................6 Order code for evaluation unit ......................6 INSTALLATION ............................7 Electrical connection (see installation instructions for the FMS measuring roller) ......9 OPERATION AND SURFACE ......................... 12 Navigation, quick start ........................12 Histogram ............................14 CONFIGURATION............................
  • Page 3 Operating Manual BMGZ710 and BMGZ710.PNET OPTIONAL ETHERNET INTERFACE – PROFINET ................39 Ethernet Configuration Device – FOR PROFINET DEVICE ONLY ..........39 10.1 10.2 Communication ..........................42 10.2.1 Function ........................... 42 10.2.2 Services und Protocols ......................43 10.3 Cyclic data traffic ..........................43 10.4...
  • Page 4: Safety Instructions

    Operating Manual BMGZ710 and BMGZ710.PNET 2 Safety instructions All safety, operating, and installation instructions given here serve to ensure that the device functions properly. They must be observed in all circumstances to ensure the safe operation of systems. Failure to comply with the safety instructions or use of the devices outside of the specified performance characteristics may endanger the safety and health of persons.
  • Page 5: Product Information

    Operating Manual BMGZ710 and BMGZ710.PNET 3 Product information 3.1 System configuration Figure1: Measuring roller and evaluation unit 3.2 Product description The evaluation units in the BMGZ700 series are designed to meet the demanding conditions of applications in mobile and stationary conveyor systems. The illuminated graphical display shows the current flow rate, the daily amount, the total amount, and the belt speed.
  • Page 6: Scope Of Delivery

    Operating Manual BMGZ710 and BMGZ710.PNET 3.4 Scope of delivery Included in the delivery: Evaluation unit; for the .K version, the evaluation unit is preinstalled in the control cabinet Not included in the delivery: Power supply unit, installation materials Also available: Measuring roller, connection cable from evaluation unit to measuring roller (specify length), M12 d-coded Ethernet cable, or RJ45 patch cable for web browser.
  • Page 7: Installation

    Operating Manual BMGZ710 and BMGZ710.PNET 4 Installation Several versions of the evaluation unit are available. Figure3: BMGZ710.W Wall mount Unscrew the 4 screws on the cover with the membrane control panel and display The cover can now be opened The housing is screwed on through the 4 holes in the bottom of the housing Figure4: BMGZ710.S Panel mount...
  • Page 8 Operating Manual BMGZ710 and BMGZ710.PNET Figure5: BMGZ710.K Cabinet The cabinet is screwed on through the 4 holes in the back wall Use the rubber mounts if the system experiences vibrations Figure6: Speciality BMGZ710.K 29.01.2024...
  • Page 9: Electrical Connection (See Installation Instructions For The Fms Measuring Roller)

    Operating Manual BMGZ710 and BMGZ710.PNET 4.1 Electrical connection (see installation instructions for the FMS measuring roller) The connection between the measuring roller and the evaluation unit must use the 8- core twisted-pair cable (4x2x0.75 mm ) provided. The cable must be laid away from any power cables to ensure that no interference is induced in the measurement signal.
  • Page 10 Operating Manual BMGZ710 and BMGZ710.PNET Figure8: Terminal assignment BMGZ710 29.01.2024...
  • Page 11 Operating Manual BMGZ710 and BMGZ710.PNET Figure9: ethernet connector M12, D-coded Figure10: Connection cable, measuring roller side 29.01.2024...
  • Page 12: Operation And Surface

    Operating Manual BMGZ710 and BMGZ710.PNET 5 Operation and surface Figure11: View of device 5.1 Navigation, quick start The menu is divided into two levels To navigate between levels, use the softkeys (menu) or Level 1: HOME Display current system data with different representations...
  • Page 13 Operating Manual BMGZ710 and BMGZ710.PNET Levels, navigation Levels Navigation Display HOME Home Histogram Zero setting Batch Detail 29.01.2024...
  • Page 14: Histogram

    Operating Manual BMGZ710 and BMGZ710.PNET Press "Menu" CONFIGURATION Press PARAMETER Table 1: levels, display 5.2 Histogram Pressing "Edit" takes you to the configuration of the display. The "Scaling" parameter allows you to adjust the division of the vertical axis. The "Recording"...
  • Page 15: Configuration

    Operating Manual BMGZ710 and BMGZ710.PNET 6 Configuration 6.1 Machine parameters The machine parameters directly affect the weighing results. Machine parameters Parameter Unit Selection Default Min. Max. Offset [Digit] -32768 32767 Gain Belt length 5000 Diameter [mm] 1000 Pulse Distance [mm]...
  • Page 16 Operating Manual BMGZ710 and BMGZ710.PNET Parameter Name Description Belt length The unrolled length of the conveyor belt is saved under this parameter. This value is required for taring. Unit Min. Max. 5000 Default Increment Diameter The diameter of the centre roller is saved under this parameter (see measuring roller nameplate).
  • Page 17 Operating Manual BMGZ710 and BMGZ710.PNET Parameter Name Description Nominal force Nominal force of the force senors. This value is indicated on the label of the measuring roller and the labels of each force sensor. See measuring roller nameplate. Unit Min.
  • Page 18: Operating Parameters

    Operating Manual BMGZ710 and BMGZ710.PNET 6.2 Operating parameters Operating parameters Parameter Unit Selection Default Min. Max. Pulse output [kg] 10000 Current output 0 to 20; 4 to 20 mA 4 to 20 mA Filter output [Hz] 10.0 20.0 Scaling [t/h] 1000.0...
  • Page 19: Description Of Operating Parameters

    Operating Manual BMGZ710 and BMGZ710.PNET 6.2.1 Description of operating parameters Operating parameters Name Description Pulse output This output emits a pulse each time the defined weight has passed the measuring roller. The weight corresponding to one pulse is stored under this parameter.
  • Page 20: System Parameters

    Operating Manual BMGZ710 and BMGZ710.PNET Operating parameters Name Description Scaling output Here, you can define the flow rate that generates the maximum output signal (10 V or 20 mA) at the analogue outputs. The resolution is 12 bits. Unit Min.
  • Page 21: Description Of System Parameters

    Operating Manual BMGZ710 and BMGZ710.PNET 6.3.1 Description of system parameters System parameters Name Description Language This parameter allows the display language to be selected. Either German or English can be selected. Unit Selection German, English Default German Filter display First-order low-pass filter to filter out undesirable fluctuations from the display.
  • Page 22: Service

    Operating Manual BMGZ710 and BMGZ710.PNET System parameters Name Description Subnet mask The subnet mask is entered in four blocks. Unit Min. Max. Default 255.255.255.0 Table 6: Description of system parameters 6.4 Service Service Parameter Unit Display A/D values raw Digit...
  • Page 23 Operating Manual BMGZ710 and BMGZ710.PNET Q [t/h] > scaling >10V or >20mA. Check scaling The analog output (DAC) is limited (> 4095 Digits), which would lead to more than 10V or 20mA. → check scaling 3 Analog output < minimum Q [t/h] <...
  • Page 24: Digital Inputs

    Operating Manual BMGZ710 and BMGZ710.PNET 6.5 Digital inputs The functions of the digital inputs are preconfigured and cannot be changed. 6.5.1 Digital input 1 (zero setting) Setting this input begins the procedure for zero setting. Setting the input to inactive aborts the ongoing procedure.
  • Page 25: Digital Outputs

    Operating Manual BMGZ710 and BMGZ710.PNET 6.6 Digital outputs The functions of the digital outputs are pre-configured and cannot be changed. 6.6.1 Digital output 1 (BMGZ OK) 24 VDC, max. 100 mA This output is always “active” if the evaluation unit is switched on and there is no error.
  • Page 26: Standard Procedures

    Operating Manual BMGZ710 and BMGZ710.PNET 7 Standard procedures 7.1 Taring (zero setting) Taring ensures that no weight is integrated when the belt is idling to avoid weighing errors. The weight of the belt and the measuring roller are subtracted from the measurement.
  • Page 27: Calibrating

    Operating Manual BMGZ710 and BMGZ710.PNET Setting the “taring” digital input begins the recalculation of the offset. The “taring active” digital output is set until the procedure is completed or aborted. If the “taring” input is reset before the remaining time has elapsed, the procedure is aborted, the “taring active”...
  • Page 28: Manual Batch Weighing

    Operating Manual BMGZ710 and BMGZ710.PNET 7.3 Manual batch weighing Figure15: Manual weighing of a batch Start the conveyor belt without any load Press the “Reset” softkey on the home screen The batch amount is set to zero The batch counter is incremented Run the desired amount over the conveyor system.
  • Page 29: Configuration Via Web Interface

    Operating Manual BMGZ710 and BMGZ710.PNET 8 Configuration via web interface You can configure the evaluation unit using a web browser (Internet Explorer 7 or higher). To do this, either connect the web guiding controller to an Ethernet network or connect it directly to a PC.
  • Page 30 Operating Manual BMGZ710 and BMGZ710.PNET Figure18: Status of LAN connection Figure19: Status of LAN connection Select “Properties” The “Local Area Connection Properties” window will open Select “Internet Protocol Version 4 (TCP/IPv4)”. Select “Properties”. The corresponding window will open. 29.01.2024...
  • Page 31 Operating Manual BMGZ710 and BMGZ710.PNET Figure20: Internet protocol properties Select “Use the following IP address:” Enter the PC address (e.g. 192.168.000.1) In the subnet mask, enter: 255 255 255 000 Close the window with “OK”. Close all other windows The computer is now ready to communicate with the evaluation unit: Open a web browser (Microsoft Internet Explorer, Mozilla Firefox, etc.)
  • Page 32: Home Screen

    Operating Manual BMGZ710 and BMGZ710.PNET 8.2 Home screen Figure21: Home screen with device information The home page gives information about general device properties, such as the serial number and software version. The menu on the left side of the screen allows you to navigate on the page.
  • Page 33: Parameters

    Operating Manual BMGZ710 and BMGZ710.PNET 8.4 Parameters The parameters page allows you to modify the parameters. In PROFINET environments, this is usually done from the PLC. Figure23: Parameters Press “Save changes” to save any modifications, or they will be lost.
  • Page 34: Alibi Protocol

    Operating Manual BMGZ710 and BMGZ710.PNET 8.5 Alibi protocol Figure24: Alibi protocol Index – consecutive numbering Start – start time and date of the batch measurement End – end time and date of the batch measurement Batch no. – saved batch number; missing batch numbers correspond to measurements made with “Reset”...
  • Page 35: Ethernet Settings

    Operating Manual BMGZ710 and BMGZ710.PNET 8.6 Ethernet settings Figure25: Ethernet settings 8.7 System settings The internal firmware version can be seen on the system settings page. New firmware can also be loaded here. Figure26: System settings The latest firmware files can be found in the download section of our website.
  • Page 36: Dimensions

    Operating Manual BMGZ710 and BMGZ710.PNET 9 Dimensions Figure27: Dimensions BMGZ710.W 29.01.2024...
  • Page 37 Operating Manual BMGZ710 and BMGZ710.PNET Figure28: Dimensions BMGZ710.S 29.01.2024...
  • Page 38 Operating Manual BMGZ710 and BMGZ710.PNET Figure29: Dimensions BMGZ710.K 29.01.2024...
  • Page 39: Optional Ethernet Interface - Profinet

    Operating Manual BMGZ710 and BMGZ710.PNET 10 Optional ethernet interface – PROFINET A PROFINET interface is available for the electronics of the BMGZ700 series with the option .PNET. BMGZ710.PNET BMGZ750.PNET – calibratable version, see separate operating manual Figure 30: peripherical devices 10.1 Ethernet Configuration Device –...
  • Page 40 Operating Manual BMGZ710 and BMGZ710.PNET Connect the measuring amplifier with your PC. Please note that the ethernet port on your PC has an IP address that is set to static. Start the program Figure 1: Ethernet Device Configuration – initial screen Select the device and press «Configure»...
  • Page 41 Operating Manual BMGZ710 and BMGZ710.PNET Figure 3: Ethernet Device Configuration – IP Configuration Enter the desired IP address and also set the subnet mask to 255.255.255.0 29.01.2024...
  • Page 42: Communication

    Operating Manual BMGZ710 and BMGZ710.PNET Figure 4: Ethernet Device Configuration – IP Adresse geändert Press «OK» to store the settings. 10.2 Communication With the acyclic data exchange, IO devices (slaves) can be parameterized, configured or status information can be read out. This is accomplished with the read/write frames via the standard IT services using UDP/IP.Allgemeine...
  • Page 43: Services Und Protocols

    Operating Manual BMGZ710 and BMGZ710.PNET A computer with the corresponding application can now request a "read" or "write" to a data model of the controller. This executes the read/write command via PROFINET and returns the status or the data to the computer.
  • Page 44 Operating Manual BMGZ710 and BMGZ710.PNET Sub- Type Parameter Unit Valid range Description slot and number format Bit 0 State of Digital True Taring belt scale (edge triggered ↑) Input 1 Taring belt scale False No action Bit 1: State of Digital True Start batch (edge triggered ↑)
  • Page 45 Operating Manual BMGZ710 and BMGZ710.PNET Sub- Type Parameter Unit Valid range Description slot and number format INT32 0 to Delivery rate 5'000'000 #.### INT32 0 to Conveyor belt speed 10'000'00 #.## INT32 Raw ADC value Digit -32'768 to Read ADC input value without signal 32'767 processing.
  • Page 46: Acyclic Data Traffic

    Operating Manual BMGZ710 and BMGZ710.PNET 10.4 Acyclic data traffic After successful system startup, IO controllers and the assigned IO devices can exchange acyclic demand data. The table below shows which parameters and commands are transmitted in which form with the acyclic data traffic.
  • Page 47 Operating Manual BMGZ710 and BMGZ710.PNET A PLC can exchange acyclic data with the evaluation electronics. This data is used for configuration and remote control of the evaluation electronics. The following table shows all commands for parameter configuration. The parameters can be read and written.
  • Page 48 Operating Manual BMGZ710 and BMGZ710.PNET Sub- Type Parameter Unit Valid range Description slot and number format UINT16 Language German English UINT16 Filter display 1 to 100 UINT16 Date format DD.MM.YYYY MM/DD/YYYY INT32 Device Time of day 0 to Current device time. The value...
  • Page 49 Operating Manual BMGZ710 and BMGZ710.PNET Sub- Type Parameter Unit Valid range Description slot and number format UINT16 Logged end date Date 4018 to End date of the logged batch. 42404 The value represents the number of days since 1990-1-1 (4018 = 2001-1-1 / 42404 = 2106-02-...
  • Page 50 Operating Manual BMGZ710 and BMGZ710.PNET The following table shows the commands for remote control. For the remote control commands, only writing is useful. Note, however, that it is possible to write the same value again. This will also execute the command again.
  • Page 51: Technical Data Bmgz710

    Operating Manual BMGZ710 and BMGZ710.PNET 11 Technical data BMGZ710 Table 7: Technical data BMGZ710 11.1 Specification PROFINET interface Table 8: specifications PROFINET 29.01.2024...
  • Page 52 Operating Manual BMGZ710 and BMGZ710.PNET FMS Force Measuring Systems AG FMS USA, Inc. Aspstrasse 6 2155 Stonington Avenue Suite 119 8154 Oberglatt (Switzerland) Hoffman Estates,, IL 60169 (USA) Tel. +41 44 852 80 80 Tel. +1 847 519 4400 info@fms-technology.com fmsusa@fms-technology.com...

This manual is also suitable for:

Bmgz710.pnet

Table of Contents