Operating Manual EMGZ309._.EIP Table of contents Safety Instructions .................. 4 1.1 Description conditions 1.2 List of safety instructions Product Description ................5 2.1 Product Range 2.2 Block Diagram 2.3 System Description EMGZ309 2.4 System Description EMGZ309._.EIP Quick Installation Guide ................. 7 3.1 Preparations for Set-up 3.2 Installation Procedure 3.3 Installation and wiring...
Page 3
Operating Manual EMGZ309._.EIP Parameterization over the Operating Panel ........24 8.1 Reset to Default Parameter Set 8.2 Parameter List 8.3 Description of Parameters Parameter Setting via a PC ..............33 9.1 Parameterization in an Ethernet Network via Web Browser 9.2 Offsetkompensation über einen Webbrowser 9.3 Calibration via the Web Browser 9.4 Parameterization via a PC (peer-to-peer connection) Dimensions ...................
Operating Manual EMGZ309._.EIP 1 Safety Instructions 1.1 Description conditions a) High danger of health injury or loss of life Danger This symbol refers to high risk for persons to get health injury or loss of life. It has to be followed strictly. b) Risk of damage of machines Caution This symbol refers to informations, that, if ignored, could cause heavy mecanical...
2.3 System Description EMGZ309 The digital tension measuring amplifiers EMGZ309 are suitable for tension measurement with all FMS force sensors. The amplifier can handle 1 or 2 force sensors. Three different analogue output modes can be selected (0…20mA, 4…20mA or 0…10 VDC). As a plug & play unit the setup through the operating panel is straightforward and quickly accomplished.
Operating Manual EMGZ309._.EIP Fig. 2: System Configuration EMGZ309 Amplifier using the analogue output E309019e 2.4 System Description EMGZ309._.EIP The amplifier EMGZ321._.EIP offers in addition to his standard features the possibility to be used as an EtherNet/IP device in a corresponding network. EtherNet/IP bases on the Ethernet TCP/IP and the UDP technology as well as on the CIP (Common Industrial Protocol).
Operating Manual EMGZ309._.EIP 3 Quick Installation Guide In a Plug & Play configuration the set-up of the EMGZ309 and force sensor is limited to only the offset compensation and the calibration. 3.1 Preparations for Set-up 1. Read the Operation Manual of your force measuring sensors 2.
Operating Manual EMGZ309._.EIP 3.4 Mounting the Force Sensors Mounting of the force sensors is done according to the FMS Installation manual which is delivered together with the force sensors. 3.5 Wiring the Amplifier One or two force sensors can be connected to the measuring amplifier. When using two force sensors, the sensors are internally connected in parallel.
Page 9
Operating Manual EMGZ309._.EIP Caution Bad earth ground connection may cause electric shock to persons, malfunction of the total system or damage of the electronic unit! It is vital to ensure that proper earth connection is done. The cable must be installed separate from power lines Note The shield should be connected only to the electronic unit.
Operating Manual EMGZ309._.EIP 4 Configuring the Amplifier The amplifier EMGZ309._.EIP can be configured over the operation panel (chapter 8), over a PC (web interface, chapter 9) or over EtherNet/IP. The basic configuration is performed over the operation panel. 4.1 Power up the EMGZ 309._.EIP 1.
Operating Manual EMGZ309._.EIP 4.3 Change the Measuring Units The default tension measuring units is N (Newton). The user can, however, select another unit before the calibration process. To select the units of measure, follow the steps below: 1. Hold the PARA key until the display changes to [Dis. Filt] 2.
The second method based calculation method conjunction with the FMS Calculator. This Calculator can be down loaded from the FMS web page. Please consult the factory for this option. Fig. 7: Calibrating the measuring amplifierC431011e Note If the Device Mode is set to [VoltGaug], the force corresponding to the calibration weight must be input in Volt (V) in the following calibration procedure.
Operating Manual EMGZ309._.EIP 4.8 Calibration over the Operating Panel 1. Load a rope with a defined weight corresponding to your calibration force on the roller. The roller configuration must correspond to the real configuration in the machine (wrap angle, distance of the rollers etc.). 2.
If necessary download and install FMS-calculator from the FMS homepage at: http://www.fms-technology.com/en/technical-information.php Gain-calculation-tool The gain calculator is an optional feature of the FMS-calculator. It delivers the gain factor for easy weightless calibration of FMS amplifiers. 1. First, the application related parameters must be entered in the FMS-calculator e.g.
Page 15
Fig. 9: Gain calculation tool E309_gain_e.jpg Calibration Procedure: 1. Calculate the gain factor with the FMS-calculator as described. 2. Press the PARA key for longer then 3 seconds to entered the parametrisation mode. 3. Scroll up or down the parameter menu with the keys until the display show [Gain].
If these prerequisites are given, the controller will recognise the amplifier as an EtherNet/IP device in the network and be able to communicate with it. The interface information for EMGZ309._.EIP is defined in an EDS-file. EDS-files for EMGZ309._.EIP can be downloaded from the FMS webpage. Link: http://www.fms-technology.com/en/eds-files.php...
Operating Manual EMGZ309._.EIP 5.4 Configuration of the Amplifier over EtherNet/IP EMGZ309._.EIP may, but need not be configured via EtherNet/IP. The Amplifier can be configured by means of a machine control unit, provided this unit is integrated in the same network. The communication between machine control and amplifier is carried out with dedicated software (e.g.
Operating Manual EMGZ309._.EIP 6 Integration in an Allen-Bradley PLC Following chapters deal with the integration and operation of the EMGZ309._.EIP amplifier with an Allen-Bradley PLC. The project software RSLogix5000 from Allen- Bradley is required to program the PLC. Furthermore, it is assumed that a development system with PC and corresponding development software RSLogix from Rockwell Automation is available and the programmer is familiar with these tools..
Page 19
Operating Manual EMGZ309._.EIP Fig. 10: Controller Organisation E309021 In this example CompactLogixL23E-QB1B is used. If a different hardware is used, one may find the listing Ethernet in another place. However, the principal approach is always the same. After a right mouse click on Ethernet a dialog window will open up.
Page 20
Operating Manual EMGZ309._.EIP Open plus-sign [+] in front of Communications to see all the other listings. Fig. 11: Module Selection E309022 Select ETHERNET- MODULE Generic Ethernet Module confirm with OK. Fig. 12: : Module Selection open E309023 Following window opens up in which the Name EMGZ309_91, Comm Format DINT and...
Operating Manual EMGZ309._.EIP The dialog window (Fig. 14) will open up. Here, one can enter the cycle time. This determines how often the data will be propagated in the network. The minimal cycle time is 2 ms. Default setting is 10 ms.
Operating Manual EMGZ309._.EIP 7 Operation 7.1 Operating the EMGZ309 over the Operating Panel The EMGZ309 amplifier can go in 5 different states: Operation State: Amplifier operating Display Selection: Selection of force or output reading Offset Compensation: Automatic procedure to offset the roller weight ...
Operating Manual EMGZ309._.EIP 7.2 Display Value Selection State The EMGZ309 can display either a tension value or the amplifier output that is an electrical unit corresponding to the measured tension. A) For tension display following unit can be selected: N, kN, lb, g, kg B) The amplifier output can be displayed in 0…10VDC, 0…20mA or 4…20mA 7.3 Displaying of Overload, Over and Underflow In the Operation State the EMGZ309 amplifier will indicate limit violations on the...
Operating Manual EMGZ309._.EIP 8 Parameterization over the Operating Panel After offset compensation and calibration the system is configured. It can now be put into operation. The following state diagrams (Fig. 17 to 19) help to navigate through the parameter setting menu. In the Parameterisation State the EMGZ309 can be brought into the 2 modes: “Parameter Selection”...
Page 25
Operating Manual EMGZ309._.EIP The display shows the unit of measure that was previously selected. Permanent key pressing expedites the changing speed. If the Device Mode [VoltGauge] is set, these parameters are deactivated Fig. 18: State Diagram Parameter Setting (2 part) E309017e...
Operating Manual EMGZ309._.EIP Fig. 19: State Diagram Parameter Setting (3 part) E309027e 8.1 Reset to Default Parameter Set Factory settings of your EMGZ309 amplifier can be re-established either over the parameter setting menu (see 8.3 “Description of Parameters”) or as shown below: Fig.
Operating Manual EMGZ309._.EIP 8.3 Description of Parameters Display Filter LCD: Dis.Filt Use: The display filter (lowpass) steadies the value shown in the display when there is a high fluctuation of the force values. The parameter Dis.Filt stores the cut off frequency of the filter. The lower the cut off frequency, the more sluggish the display will be.
Page 29
Operating Manual EMGZ309._.EIP System Force LCD: SysForce Use: The System Force [SysForce] determines the measuring capability of your measuring roller. E.g. If two 500 N sensors are installed in your measuring roller, enter 1000N. If only one 500N sensor is used, enter 500N.
Page 30
This parameter stores the value determined with the Procedure Calibration (see 4.7 “Calibration over the Operating Panel”). Alternatively you can input a calculated value using the FMS Calculator described in chapter 4.8, if the material tension cannot be simulated. Parameter Range...
Page 31
The Ethernet interface of EMGZ309 can be switched on and off with this parameter. The deactivation of this interface reduces the power consumption by 25% and lowers heat generation in the device considerably. FMS recommends to activated the Ethernet interface only when needed.. Parameter Range...
Page 32
Operating Manual EMGZ309._.EIP Subnet Mask Address LCD: Subnet Use: The parameter assigns the Subnet Mask of the amplifier in the Ethernet network. This enables the user to communicate via a web browser with the controller. The Subnet Mask must be entered in 4 separate blocks (Sub.
Operating Manual EMGZ309._.EIP 9 Parameter Setting via a PC The EMGZ309 amplifier can be embedded in an Ethernet network and the parameter setting can be done over this network by means of web browser (Internet Explorer 7 or higher or Firefox 3.5 or higher). The devices have a static IP-address that can be set over the user interface.
Operating Manual EMGZ309._.EIP 9.1 Parameterization in an Ethernet Network via Web Browser First of all it must be certain that the EMGZ309 uses an IP address in a static block (not assigned by the server). For the integration of an EMGZ309 amplifier in your EtherNet network please contact your IT system administrator.
Page 35
Operating Manual EMGZ309._.EIP Fig. 25: Current Reading for Device Mode Force Gauge Current Reading Force Fig. 26: Current Reading for Device Mode Volt Gauge Current Reading Volt...
Page 36
Operating Manual EMGZ309._.EIP Fig. 27: Parameter list for Device Mode Force Gauge Parameters-Force Fig. 28: Parameter list for Device Mode Volt Gauge Parameters-Volt...
Page 37
Operating Manual EMGZ309._.EIP Fig. 29: Offset compensation and calibration for Device Mode Force Gauge Offset-Calibration-Force Fig. 30: Offset compensation and calibration for Device Mode Volt Gauge Offset-Calibration-Volt...
2. Enter the force corresponding to your calibration weight in Volt (V) in the field “Weight”. If this value is not known, the calibration method with the FMS- Calculator can be used to determine it. (see chapter 4.9 „Analytic Calibration...
The following chapter describes the procedure for setting up a desktop or laptop computer to communicate with FMS EMGZ309 amplifier. Before connecting the FMS EMGZ309 amplifier with a “cross over cable” directly to a PC, the computer must be configured with a “static” IP address that lets it recognize the EMGZ309 amplifier.
Page 41
Operating Manual EMGZ309._.EIP The following dialog box will appear. Make sure the “General” tab is selected. Select the radio button “Use the following IP address:” In the IP address box enter the IP address for the computer that could be 192.168.0.1.
Page 42
Operating Manual EMGZ309._.EIP The dialog box will change to look like the following: Click the “OK” button. The following dialog box will appear again:...
Page 43
Operating Manual EMGZ309._.EIP Click on the “Close” button. Close the “Network Connection” window Close “Control Panel” The computer is now ready to communicate with the EMGZ309 amplifier: 1. Connect the “cross over cable” to both the EMGZ309 and to the appropriate port on the desktop or laptop computer.
Operating Manual EMGZ309._.EIP 10 Dimensions The EMGZ309 series is available in three different housing options. The mechanical dimensions can be seen in the following pages. Fig. 33: Outline Drawing EMGZ309.R rail mount housing E309006e Ethernet connection: RJ-45 connector...
Operating Manual EMGZ309._.EIP 11 Technical Specification Sensor excitation 5VDC max. 60mA (high voltage stability) Temperature drift offset < 0.01% / K [0.006% / °F] Linearity error < 0.1% Processor cycle time Operation /Parameter Setting 3 keys and LCD 2x8 characters (size 8mm) EtherNet/IP-Bus Interface (optional) Standard: CIP über IEE 802.3...