  • Page 1 Intel® Storage Server SSR212MC2/ SSR212MC2R User Guide ® A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number D90842-002...
  • Page 2 Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
  • Page 3 Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http://support.intel.com/support/motherboards/server/sb/cs- 010770.htm. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor...
  • Page 4 Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 5 Preface About this Manual Thank you for purchasing and using the Intel® Storage Server SSR212MC2/ SSR212MC2R. This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this storage system. This document provides a brief overview of...
  • Page 6 Hardware (peripheral Tested Hardware Operating Systems List boards, adapter cards) and operating systems that have been tested with this product For software to manage StorView* Enclosure Management Software ® your Intel storage system Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 7 Preparation of Site and Host Server ..................17 Unpacking the Enclosure System ..................... 17 Planning and Configuring Your Installation ................17 Rack Installation Prerequisites ....................18 Installing the Enclosure in a Rack ..................18 Rail Kit Assembly ........................19 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 8 Removing and Installing the Processor Air Duct ..............44 Removing the Processor Air Duct .................... 44 Installing the Processor Air Duct ....................45 Installing and Removing Memory ..................45 Installing FBDIMMs ........................45 viii Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 9 Replacing a Server Board ....................97 Replacing the SAS Expander PCB ..................107 Replacing an Intel® RAID Controller SRCSAS144E ............110 Replacing the Intel® Intelligent AXXRIBBU1 Battery Backup Unit ........112 Installing the Boot Drives ....................115 Installing an Add-in Board ....................122 Troubleshooting and Problem Solving ..............125 Overview ..........................125...
  • Page 10 C Setting up RAID on the Intel® Storage Server SSR212MC2R ......139 Enter RAID BIOS Console ....................139 Create a RAID Volume ...................... 140 D Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 Start RAID Configuration Utility ..................145 Create a RAID Volume ...................... 145 E RAID Levels ......................155...
  • Page 11 Restriction of Hazardous Substances (RoHS) Compliance ..........171 End of Life / Product Recycling ..................172 H Warranty ......................173 Limited Warranty for Intel® Chassis Subassembly Products ..........173 Extent of Limited Warranty ....................173 Warranty Limitations and Exclusions .................174 Limitations of Liability ......................174 How to Obtain Warranty Service ....................
  • Page 12 Advertencias y precauciones sobre seguridad ............... 206 Aplicaciones y usos previstos ....................207 Selección de la ubicación ....................... 207 Manipulación del equipo ......................207 Advertencias el acceso al sistema ..................209 Descarga electrostática (ESD) ....................210 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 13 List of Figures List of Figures Figure 1. Intel® Storage Server SSR212MC2/SSR212MC2R - Front View....... 1 Figure 2. Intel® Storage Server SSR212MC2/SSR212MC2R - Rear View Showing Service Ar- eas............................2 Figure 3. Rear View........................3 Figure 4. Front View ........................4 Figure 5.
  • Page 14 Figure 96. Re-installing Brace Assembly ................. 88 Figure 97. Removing Brace Assembly..................90 Figure 98. Removing Boot Drive Module ................. 90 Figure 99. Locating IDE Connector on the Server Board ............91 Figure 100. Removing IDE DOM ..................... 91 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 15 Figure 127. Removing Battery Assembly from Battery Backup Unit ........113 Figure 128. Attaching Battery to Battery Backup Unit ............114 Figure 129. Installing the New Intel® Intelligent AXXRIBBU1 Battery Backup Unit ....114 Figure 130. Removing Brace Assembly ................. 115 Figure 131.
  • Page 16 List of Figures Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 17 Table 6. Front Operator’s Panel Switch Functions..............23 Table 7. Intel® Storage Server SSR212MC2 Boot Drive Cable Connections......61 Table 8. Intel® Storage Server SSR212MC2 Boot Drive SAS/SATA Cable Connections ..61 Table 9. Intel® Storage Server SSR212MC2R Boot Drive Cable Connections ....... 63 Table 10.
  • Page 18 List of Tables xviii Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 19 Storage Server Features The Intel® Storage Server SSR212MC2/SSR212MC2R is a 2U (rack space) disk drive enclosure, currently housing twelve low-profile (1-in high), 1.5/3.0 Gb/s, 3.5-in form factor SAS/SATA disk drives. Each individual disk drive is field replaceable. Figure 1 shows a front view of the Intel® Storage Server SSR212MC2/SSR212MC2R...
  • Page 20 D. Boot Drive E. Server Board F. PCI Slots Enclosure Core Product The Intel® Storage Server SSR212MC2/SSR212MC2R design concept is based on an enclosure sub-system together with a set of plug-in modules and (as supplied) consists of: • An enclosure chassis with: —...
  • Page 21 Note: If only one PSU is installed, a blanking plate must be fitted over the empty upper bay. • A server subsystem comprising: — An Intel® Server Board S5000PSL with integral I/O panel — An Intel® RAID Controller SRCSAS144E — An Intel® Intelligent AXXRIBBU1 Battery Backup Unit — A boot drive module •...
  • Page 22 Figure 4. Front View Enclosure Chassis Figure 5. Enclosure Chassis The enclosure chassis consists of a sheet metal enclosure assembly containing an integrated backplane printed circuit board (PCB), an enclosure management PCB, and a module runner system. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 23 Slots for up to six low-profile 3/4-length PCI cards, installed in a vertical orientation.The following PCBs are installed as standard configuration: — (SSR212MC2R only) An Intel® RAID Controller SRCSAS144E, in the left-hand slot (when viewed from the rear) — (SSR212MC2R only) An Intel® Intelligent AXXRIBBU1 Battery Backup Unit, in the right-hand slot (when viewed from the rear) Blank PCI plates are filled in the empty PCI slots.
  • Page 24 • PS2 mouse port • PS2 keyboard port • Serial port • Video port • Two RJ-45 ports - NICs 1 and 2 (1Gb each) • Four USB ports: 0, 1, 2, and 3 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 25 Storage Server Features Server Board LEDs See your Intel® Server Board S5000PSL User Guide for full details on I/O panel LED states. Status LEDs Diagnostic LEDs are present on the server board I/O panel to assist in identifying failed and failing components. See “Server Board LEDs”...
  • Page 26 Used to identify a server from among several servers Power Supply Unit AC-DC power is provided by a commercial dual-redundant power supply with specific load capability, mechanical packaging and output loom to suit this product. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 27 (green/red) LED to indicate PSU status. Multiple Power Supply Units The Intel® Storage Server SSR212MC2/SSR212MC2R can be operated with either one or two PSUs fitted in the power supply mounting cage. If two PSUs are fitted, they provide redundancy for the system so that if one PSU fails the other maintains the power supply while the faulty PSU is being replaced.
  • Page 28 The cooling cage contains ten individual high-speed single-rotor axial fans, individually connected to and interfacing with the enclosure management PCB. This interface provides power and speed control to the fans and returns tacho output from each fan to the management system. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 29 LED) mounted on the front cap of each drive carrier module. See “Disk Drive LEDs” on page 24 for a description of LED states. A. Green LED B. Amber LED C. Torque Screw D. Drive Lock Indicator Aperture Figure 12. Drive Status LEDs and Components Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 30 Warning: Operation of the enclosure with ANY modules missing will disrupt the airflow and the drives will not receive sufficient cooling. Spare Parts and Accessories The following replaceable parts are available for the Intel® Storage Server SSR212MC2/ SSR212MC2R. Table 3. Spare Parts and Accessories...
  • Page 31 Hot swap fans (5 pack) FMCSASX SAS expander card FMCAIRBAFFLE Processor and memory air ducts BB5000PSLSAS 10-pack of Intel® Server Board S5000PSL with integrated 4-port SRCSAS144E 10-pack of Intel® RAID Controller SRCSAS144E AXXRIBBU1 Intel® Intelligent AXXRIBBU1 Battery Backup Unit AMC850WPS...
  • Page 32 Storage Server Features Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 33 Getting Started In this chapter, you are shown how to plan and install your Intel® Storage Server SSR212MC2/SSR212MC2R into an industry standard 19-inch rack cabinet. Caution: When connecting up the Intel® Storage Server SSR212MC2/SSR212MC2R, use only the power cords supplied or power cords which match the specification quoted in “Power...
  • Page 34 1 x 4 bay bank would take the space of one drive width by four drive bays across (in the rack mount configuration). The Intel® Storage Server SSR212MC2/SSR212MC2R subsystem is housed in a 4 x 3 enclosure, i.e., four drive bays wide by three bays high. The top bays are numbered 1 to 4 from left to right, as viewed from the front.
  • Page 35 Getting Started Preparation of Site and Host Server Before beginning, make sure that the site where you intend to set up and use your Intel® Storage Server SSR212MC2/SSR212MC2R has standard AC power available from an independent source or a rack power distribution unit with a UPS (universal power supply).
  • Page 36 Installing the Enclosure in a Rack A set of rack-mounting rails is provided with the system for installing the Intel® Storage Server SSR212MC2/SSR212MC2R in a 19-inch rack cabinet. These rails have been designed and tested to handle the maximum weight of the enclosure and to ensure that multiple enclosures may be installed without loss of space within the rack.
  • Page 37 Getting Started Rail Kit Assembly Refer to the Rail Kit Install Guide: Intel® Storage Server SSR212MC2/SSR212MC2R for instructions on assembling the rail kit. A. Rear Rack Post B. Clamping Screws C. Rack Bracket ASM D. Front Rack Post E. Slide Screw (4) F.
  • Page 38 The Intel® Storage Server SSR212MC2/SSR212MC2R is delivered with backplane PCB, server board, enclosure management PCB, SAS expander PCB, Front Operator’s Panel, and all plug-in modules pre-installed. The Intel® Storage Server SSR212MC2R also ships with an Intel® RAID Controller SRCSAS144E and an Intel® Intelligent AXXRIBBU1 Battery Backup Unit pre-installed.
  • Page 39 Power On Caution: Do not operate the Intel® Storage Server SSR212MC2/SSR212MC2R until the ambient temperature is within the specified operating range. If the drives have been recently installed, ensure they have had time to acclimate before operating them.
  • Page 40 Functions of the push-button switches are defined in Table A. USB Port B. Power Active LED C. Unit Fault LED D. ID LED E. On/Off Switch F. Reset Button (recessed) G. ID LED Activation Switch Figure 17. Front Operator’s Panel Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 41 There may be a power problem (an alarm and power fault indication would normally be present). • In the presence of only one PSU, the drive motors will spin up in a delayed sequence. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 42 To power down the enclosure, either: • Switch off the PSU(s) installed in the enclosure by pressing the power push-button on the Front Operator’s Panel for approximately 3 seconds, • Remove AC mains at the power source. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 43 This chapter provides instructions for removing, installing, and replacing storage system components in your Intel® Storage Server SSR212MC2/SSR212MC2R. Caution: When connecting the Intel® Storage Server SSR212MC2/SSR212MC2R to a power source, use either the power cords that shipped with the system, or match the power cord specifications listed under “Power Cord”...
  • Page 44 — Access to power supply unit openings Upon replacement, the cover MUST be secured by tightening the retaining screw with a screwdriver. Removing the Enclosure Cover 1. Observe all safety and ESD precautions listed in “Safety Information” on page 189. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 45 (see letter “B”) and slide the enclosure cover back (see letter “C”) until it stops. Figure 18. Unlatching Enclosure Cover 3. Lift the cover to completely remove it from the chassis. Figure 19. Removing Enclosure Cover Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 46 A PSU can be replaced if it fails. If your storage system uses a redundant power supply system, you do not need to power down the system to replace the failed PSU as long as the remaining PSU is plugged into an AC power source and is functioning. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 47 3. For redundant PSU systems, make sure you correctly identify the faulty PSU to be replaced. 4. Switch off and disconnect the power supply bail. Disconnect the power supply cord to the faulty PSU. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 48 5. Press the locking tab to the left. Figure 21. Unlatching a Power Supply Unit 6. Grip the handle and withdraw the PSU from the mounting cage. Figure 22. Removing a Power Supply Unit Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 49 2. Check for damage to the new PSU, especially to the rear connector on the module. 3. Slide the PSU into the mounting cage. A click should be heard as the securing spring engages. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 50 Figure 24. Power Supply Unit in Place 4. Connect the AC power cable to the new PSU. Secure the power cord plug with the power supply bail. 5. On non-redundant power supply systems, power up the storage system. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 51 “EARTH LEAKAGE CURRENT” (“TOUCH CURRENT”). Prior to switching on, ensure that the earth connection to the rack has been checked by an electrical engineer qualified in local and national electrical standards. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 52 Hardware Installations and Upgrades Replacing a Cooling Fan The Intel® Storage Server SSR212MC2/SSR212MC2R has ten fans in its cooling cage to ensure proper cooling of the system. Each cooling fan can be individually replaced. Warning: The enclosure cover should only be removed by qualified service personnel as it provides access to a service area.
  • Page 53 3. Grip the faulty fan with finger and thumb and pull it upwards to unplug it from the enclosure management PCB. Remove fan from the enclosure. Figure 27. Removing a Cooling Fan 4. Check the new fan for damage. Do not install it if there are any visible signs of damage. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 54 PCB. Ensure that the fan LED extinguishes within 10 seconds of installation. Figure 28. Installing a Cooling Fan 6. Close the enclosure cover and latch securely by turning the lock mechanism to the “locked” position. Figure 29. Re-installing Enclosure Cover Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 55 “De-activating an Anti-tamper Lock” on page 41 for instructions on de-activating the lock. 3. Release the carrier handle by pressing the latch in the handle towards the handle hinge. Figure 30. Unlatching a Drive Carrier Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 56 1. Observe all safety and ESD precautions listed in “Safety Information” on page 189. 2. Release the drive carrier handle by depressing the latch in the handle. Figure 32. Unlatching a Drive Carrier Handle Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 57 5. Cam the drive carrier home until the camming foot on the base of the drive carrier engages with the enclosure. Continue to push firmly until the handle fully closes. A click should be heard as the latch engages and holds the handle closed. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 58 1. Carefully insert the TORX* screwdriver provided into the cutout in the handle (see letter “A” in the following figure). 2. Rotate the screwdriver in a clockwise direction until the lock symbol is visible in the aperture beside the key (see letter “B”). Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 59 (see letter “B”). Note: Do not turn the lock more than half a turn otherwise the drive carrier may be damaged. Figure 37. De-activating an Anti-tamper Lock 3. Remove the screwdriver. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 60 5. For instructions on re-installing the drive carrier into the drive bay, see “Installing a Drive Carrier Module” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 61 (see letter “B”). Set any jumpers for the hard drive. Figure 39. Installing Hard Drive into Drive Carrier 5. For instructions on re-installing the drive carrier into the drive bay, see “Installing a Hard Drive into a Drive Carrier” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 62 5. Lift the processor air duct from its location over the processor sockets. Figure 40. Removing the Processor Air Duct 6. If removing a processor air duct as part of another procedure, continue with that procedure. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 63 Caution: Before performing any maintenance on the system, back up the data. Follow the instructions in the operating system manual for shutting down the system. Warning: Do not operate the Intel® Storage Server SSR212MC2/SSR212MC2R without the presence of a processor air duct.
  • Page 64 5. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page 6. Locate the DIMM sockets. Callout DIMM Socket Callout DIMM Socket DIMM_A1 DIMM_C1 DIMM_A2 DIMM_C2 DIMM_B1 DIMM_D1 DIMM_B2 DIMM_D2 Figure 42. Locating FBDIMM Sockets Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 65 3. Disconnect the AC power cord(s). 4. Remove the enclosure cover. For instructions, see “Removing the Enclosure Cover” on page 5. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 66 “Installing the Processor Air Duct” on page 10. Re-install the enclosure cover. For instructions, see “Installing the Enclosure Cover” on page 11. Reconnect all peripheral devices and the AC power cord(s). Power up the storage system. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 67 Intel® Storage Server SSR212MC2/SSR212MC2R. Caution: Reduce the risk of ESD damage to the processor by doing the following: (1) Touch the metal chassis before touching the processor or server board. Keep part of your body in contact with the metal chassis to dissipate the static charge while handling the processor.
  • Page 68 Hardware Installations and Upgrades 6. Locate the processor sockets. Callout Processor Socket Callout Processor Socket CPU_2 CPU_1 (Use this socket when installing a single processor.) Figure 45. Locating Processor Sockets Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 69 Fully open the load plate. Figure 47. Opening Load Plate 9. If the protective cover is attached to the load plate, remove it and store it for future use. Figure 48. Removing Protective Cover from Load Plate Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 70 14. Prepare the passive heatsink for installation. The heatsink has thermal interface material (TIM) located on the bottom of it. Use caution when handling the heatsink so as not to damage the TIM. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 71 In the same order, gradually and equally tighten each captive screw until all are firmly tightened. Do not fully tighten one screw at a time. Figure 50. Installing Passive Heatsink Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 72 2. Turn off all peripheral devices connected to the storage system. Power down the storage system. 3. Disconnect the AC power cord(s). 4. Remove the enclosure cover. For instructions, see “Removing the Enclosure Cover” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 73 CPU_2 CPU_1 Figure 52. Locating Processor Sockets 7. Loosen the four captive screws on the corners of the heatsink. 8. Twist the heatsink slightly to break the seal between the heatsink and the processor. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 74 Figure 53. Opening Processor Socket Lever 11. Push down on the rear tab of the load plate to swing the front of the load plate up slightly. Fully open the load plate. Figure 54. Opening Load Plate Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 75 17. Re-install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page 18. Re-install the enclosure cover. For instructions, see “Installing the Enclosure Cover” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 76 4. Remove the enclosure cover. For instructions, see “Removing the Enclosure Cover” on page 5. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page 6. Locate the CMOS battery. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 77 “Installing the Enclosure Cover” on page 13. Reconnect all peripheral devices and the AC power cord(s). Power up the storage system. 14. Run the BIOS Setup utility to restore the configuration settings to the real-time clock. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 78 See the Intel® Server Board S5000PSLUser Guide for information on setting up the server board to support either SATA or SAS options. In the Intel® Storage Server SSR212MC2, the two internal boot drives are connected to the two black SATA ports and can be used with SATA drives.
  • Page 79 Port USB port on connected to server board backplane via mini-SAS to 4x SATA Table 8. Intel® Storage Server SSR212MC2 Boot Drive SAS/SATA Cable Connections Server Board SATA Boot Drive SAS Boot Drive DOM Boot Drive Connector (as shipped) SATA 0...
  • Page 80 “Setting up RAID on the Intel® Storage Server SSR212MC2R” on page 139 information on setting up RAID 0 or RAID 1 options using these boot drives. The twelve drives connected to the storage system backplane are controlled by the Intel® RAID Controller SRCSAS144E. See the Intel® RAID Controller SRCSAS144E Software User Guide and Hardware Guide for information on configuring RAID options.
  • Page 81 Hardware Installations and Upgrades Table 9. Intel® Storage Server SSR212MC2R Boot Drive Cable Connections Boot Drive Mini-USB P4 Power 12 SAS/SATA Boot Drives Options Cable Cable Drives SAS/SATA Connected to Connected to SAS 0 connected Intel® RAID drives on boot...
  • Page 82 Hardware Installations and Upgrades Replacing or Installing a SATA DOM The Intel® Storage Server SSR212MC2/SSR212MC2R can be used with a Disk On Module (DOM) installed directly to the server board’s SATA 0 Port. A SATA DOM is a storage device based on flash memory technology, which emulates an ordinary magnetic hard drive.
  • Page 83 Figure 58. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 59. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 84 9. Press in on the latch on the side of the DOM (see letter “A” in the following figure) to release DOM from connector. Lift DOM off the connector (see letter “B”). Remove the power cable from the DOM (see letter “C”). Figure 61. Removing SATA DOM Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 85 11. Align the two holes at the back of the boot drive module with the two chassis pins. Push until seated properly. Secure the boot drive module to the chassis with the single screw previously removed. Figure 63. Re-installing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 86 Installing a SATA DOM See the documentation supplied by your vendor for more information on how to upgrade the Intel® Storage Server SSR212MC2/SSR212MC2R to use third-party software. 1. Observe all safety and ESD precautions listed in “Safety Information” on page 189.
  • Page 87 Figure 65. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 66. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 88 9. Connect the P4 power cable to the power adapter cable that came with the new SATA DOM. 10. Locate the SATA Port 0 on the server board (see letter “A” in the following figure). Figure 68. Locating SATA Port 0 on Server Board Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 89 12. Align the two holes at the back of the boot drive module with the two chassis pins. Push until seated properly. Secure the boot drive module to the chassis with the single screw previously removed. Figure 70. Re-installing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 90 Replacing or Installing a USB Header DOM The Intel® Storage Server SSR212MC2/SSR212MC2R can be used with Disk On Module (DOM) installed directly to the server board’s USB header. A USB DOM is a storage device based on flash memory technology, which emulates an ordinary magnetic hard drive.
  • Page 91 3. Disconnect the AC power cord(s). 4. Remove the enclosure cover. For instructions, see “Removing the Enclosure Cover” on page 5. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 92 Figure 72. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 73. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 93 9. Press in on both sides of the USB Header DOM (see letter “A” in the following figure) and pull up to remove from the USB header (see letter “B”). Figure 75. Removing USB Header DOM Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 94 11. Align the two holes at the back of the boot drive module with the two chassis pins. Push until seated properly. Secure the boot drive module to the chassis with the single screw previously removed. Figure 77. Re-installing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 95 Installing a USB Header DOM See the documentation supplied by your vendor for more information on how to upgrade the Intel® Storage Server SSR212MC2/SSR212MC2R to use third-party software. 1. Observe all safety and ESD precautions listed in “Safety Information” on page 189.
  • Page 96 Figure 79. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 80. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 97 Figure 81. Disconnecting Power and Disk Drive Cables from Boot Drive Module 9. Locate the USB header on the server board (see letter “A” in the following figure). Remove the mini USB cable. Figure 82. Locating USB Header on the Server Board Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 98 11. Align the two holes at the back of the boot drive module with the two chassis pins. Push until seated properly. Secure the boot drive module to the chassis with the single screw previously removed. Figure 84. Re-installing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 99 “Installing the Processor Air Duct” on page 14. Re-install the enclosure cover. For instructions, see “Installing the Enclosure Cover” on page 15. Reconnect all peripheral devices and the AC power cord(s). Power up the storage system. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 100 Hardware Installations and Upgrades Replacing or Installing a USB Flash Drive The Intel® Storage Server SSR212MC2/SSR212MC2R can be used with a USB Flash Drive installed directly to the server board’s USB port. A USB Flash Drive is a storage device based on flash memory technology, which emulates an ordinary magnetic hard drive.
  • Page 101 Figure 86. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 87. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 102 11. Align the two holes at the back of the boot drive module with the two chassis pins. Push until seated properly. Secure the boot drive module to the chassis with the single screw previously removed. Figure 89. Re-installing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 103 Installing a USB Flash Drive See the documentation supplied by your vendor for more information on how to upgrade the Intel® Storage Server SSR212MC2/SSR212MC2R to use third-party software. 1. Observe all safety and ESD precautions listed in “Safety Information” on page 189.
  • Page 104 Figure 91. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 92. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 105 Figure 93. Disconnecting Power and Disk Drive Cables from Boot Drive Module 9. Locate the USB port on the server board (see letter “A” in the following figure). Figure 94. Locating USB Port on the Server Board Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 106 12. Re-install the brace assembly (see letter “A” in the following figure). Secure to enclosure by tightening the two captive screws (see letter “B”). Figure 96. Re-installing Brace Assembly 13. Re-install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 107 Replacing or Installing an IDE DOM The Intel® Storage Server SSR212MC2/SSR212MC2R can be used with a Disk On Module (DOM) installed directly to the server board’s IDE connector. An IDE DOM is a storage device based on flash memory technology, which emulates an ordinary magnetic hard drive.
  • Page 108 Figure 97. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 98. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 109 Ensure the latches are closed enough for easy removal of the IDE DOM otherwise the housing on the IDE connector may be damaged. Disconnect the power cable from the IDE DOM (see letter “B”). Figure 100. Removing IDE DOM Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 110 11. Align the two holes at the back of the boot drive module with the two chassis pins. Push until seated properly. Secure the boot drive module to the chassis with the single screw previously removed. Figure 102. Re-installing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 111 Installing an IDE DOM See the documentation supplied by your vendor for more information on how to upgrade the Intel® Storage Server SSR212MC2/SSR212MC2R to use third-party software. 1. Observe all safety and ESD precautions listed in “Safety Information” on page 189.
  • Page 112 Figure 104. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 105. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 113 9. Connect the P4 power cable to the power adapter cable that shipped with the new IDE DOM. 10. Locate the IDE connector on the server board (see letter “A” in the following figure). Figure 107. Locating IDE Connector on the Server Board Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 114 12. Align the two holes at the back of the boot drive module with the two chassis pins. Push until seated properly. Secure the boot drive module to the chassis with the single screw previously removed. Figure 109. Re-installing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 115 Caution: Back up the data on the storage system before performing any maintenance procedures. Caution: Before installing a new server board, ensure that the server board has the correct versions of the BIOS, FRU/SDR. and mBMC installed. Refer to the Intel support site at http:// www.intel.com/support/motherboards/server/ssr212mc2...
  • Page 116 Figure 111. Removing Brace Assembly 9. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 112. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 117 Power for a USB DOM device is provided by the USB connector. 12. Remove the USB, SATA, or IDE DOM if one is present. For instructions, see the appropriate DOM removal section in this chapter. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 118 SRCSAS144E (see letter “A” in the following figure). Release the screw on the retaining bracket at the back of the enclosure (see letter “B”). Ease the Intel® Intelligent AXXRIBBU1 Battery Backup Unit out of its PCI slot (see letter “C”).
  • Page 119 SRCSAS144E. Disconnect the SAS cable (see letter “A” in the following figure). Release the screw on the retaining bracket at the back of the enclosure (see letter “B”). Lift the Intel® RAID Controller SRCSAS144E upwards and out of the enclosure (see letter “C”).
  • Page 120 17. Remove the seven screws securing the server board to the chassis. Remove server board from chassis and store in an anti-static bag. 18. Install the new server board by aligning the screw holes in the server board with the standoffs in the chassis. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 121 — Power cable to the front panel connector, uses pins 11 and 13 (see letter “M”) — Serial B/emergency management port cable (see letter “N”) 22. Re-attach standoff (see letter “O”). Figure 117. Connecting Cables and Standoff to Server Board Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 122 Hardware Installations and Upgrades 23. (Intel® Storage Server SSR212MC2R only) Install the Intel® RAID Controller SRCSAS144E in the leftmost PCI slot (see letter “A” in the following figure). Tighten the screw on the retaining bracket at the back of the enclosure (see letter “B”).
  • Page 123 AXXRIBBU1 Battery Backup Unit in the rightmost PCI slot (see letter “A” in the following figure). Tighten the screw on the retaining bracket at the back of the enclosure (see letter “B”). Connect the BBU cable to the Intel® RAID Controller SRCSAS144E (see letter “C”).
  • Page 124 Figure 121. Re-installing Brace Assembly 31. Re-install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page 32. Re-install the enclosure cover. For instructions, see “Installing the Enclosure Cover” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 125 2. Turn off all peripheral devices connected to the storage system. Power down the storage system. 3. Disconnect the AC power cord(s). 4. Remove the enclosure cover. For instructions, see “Removing the Enclosure Cover” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 126 5. Open the PCB cover (see letter “A” in the following figure). Remove the SAS cable (see letter “B”). Pull the SAS Expander PCB assembly forward, unplugging it from the backplane (see letter “C”). Figure 122. Removing the SAS Expander PCB Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 127 Figure 123. Installing the SAS Expander PCB 7. Re-install the enclosure cover. For instructions, see “Installing the Enclosure Cover” on page 8. Reconnect all peripheral devices and the AC power cord(s). Power up the storage system. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 128 Hardware Installations and Upgrades Replacing an Intel® RAID Controller SRCSAS144E The Intel® RAID Controller SRCSAS144E is installed in the left-hand PCI slot (when viewed from the rear) of the Intel® Storage Server SSR212MC2/SSR212MC2R. 1. Observe all safety and ESD precautions listed in “Safety Information”...
  • Page 129 Hardware Installations and Upgrades 6. Install the replacement Intel® RAID Controller SRCSAS144E in the leftmost PCI slot (see letter “A” in the following figure), ensuring it is seated firmly in the slot. Replace the screw removed in the previous step (see letter “B”). Reconnect the BBU cable (see letter “C”).
  • Page 130 Unit The Intel® Intelligent AXXRIBBU1 Battery Backup Unit is installed in the right-hand PCI slot (when viewed from the rear) of the Intel® Storage Server SSR212MC2/ SSR212MC2R. Warning: Risk of explosion if battery pack is replaced by an incorrect type. The battery pack must...
  • Page 131 Hardware Installations and Upgrades 5. Disconnect the BBU cable to the Intel® RAID Controller SRCSAS144E (see letter “A” in the following figure). Release the screw in the retaining bracket at the back of the enclosure (see letter “B”). Ease the Intel® Intelligent AXXRIBBU1 Battery Backup Unit out of the PCI slot (see letter “C”).
  • Page 132 PCI slot (see letter “A” in the following figure). Support the Intel® Intelligent AXXRIBBU1 Battery Backup Unit while aligning the bracket and replacing the screw removed in step 5 (see letter “B”). Connect the BBU cable to the Intel® RAID Controller SRCSAS144E (see letter “C”).
  • Page 133 6. Loosen the two captive screws securing the brace assembly to the enclosure (see letter “A” in the following figure). Lift brace assembly out of enclosure (see letter “B”). Figure 130. Removing Brace Assembly Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 134 8. Turn the boot drive module over. Disconnect the disk drive cables (see letter “A” in the following figure) and the P4 power cable (see letter “B”) from the boot drive module backplane. Figure 132. Disconnecting Power Cable and Disk Drive Cables from Boot Drive Module Backplane Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 135 Hardware Installations and Upgrades 9. Remove the two screws securing the backplane to the boot drive module. Remove the backplane from the boot drive module. Figure 133. Removing Backplane from Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 136 (see letter “A” in the following figure). Secure disk drive to boot drive module with four screws (see letter “B”). Caution: When handling drives, ensure that they are placed (and stored) on a cushioned surface. Figure 134. Installing Lower Boot Drive Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 137 11. (Optional) Install second boot drive in upper slot with circuit side facing up and connectors oriented toward backplane (see letter “A” in the following figure). Secure disk drive to boot drive module with four screws (see letter “B”). Figure 135. Installing Upper Boot Drive Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 138 — Top boot drive to SATA 1 on server board • For Intel® Storage Server SSR212MC2R — Bottom boot drive to SAS 0 on server board — Top boot drive to SAS 1 on server board Figure 137. Connector Locations on Server Board Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 139 Figure 138. Re-installing Boot Drive Module 16. Re-install brace assembly in enclosure (see letter “A” in the following figure). Secure brace assembly to enclosure by tightening the two captive screws (see letter “B”). Figure 139. Re-installing Brace Assembly Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 140 The retaining bracket fits the space that was previously occupied by the expansion slot cover. 11. Secure the add-in board to the chassis with the screw that was previously removed. 12. Attach cables, if necessary. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 141 “Installing the Processor Air Duct” on page 14. Re-install the enclosure cover. For instructions, see “Installing the Enclosure Cover” on page 15. Reconnect all peripheral devices and the AC power cord(s). Power up the storage system. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 142 Hardware Installations and Upgrades Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 143 Computer Doesn’t Recognize the Subsystem 1. Check that the interface cables from the Intel® Storage Server SSR212MC2/ SSR212MC2R to the host computer are fitted correctly. 2. Check that the LEDs on all installed drive carrier modules are illuminated (amber).
  • Page 144 (cage related) 240VA limit (cage related) Blink green Current limit Amber Front Operator’s Panel The Front Operator’s Panel displays the aggregated status of all the modules. Front Operator’s Panel LED states are defined in Table Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 145 Disk drive status is monitored by a green LED and an amber LED mounted on the front of each Drive Carrier module. The conditions for each LED are defined in “Drive Carrier Module Faults” on page 133. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 146 Left No network connection is in place Solid green Active network connection is in place Blinking green Transmit / receive activity is occurring Right 10 Mbps connection (if left LED is on or blinking) Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 147 Slow beep. Fan light Fan broken or out of Replace lit fan. constant. tolerance No beep if muted. Slow beep. Drive Drive fault Replace drive light constant. No beep if muted. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 148 Operator’s Panel ID Buzzer Front Operator’s No issues Panel Fault LED Off Front Operator’s Muted. See Front Operator’s Panel Fault LED Panel LED settings Flashing or Constant above for interpretation of lights and remedy. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 149 On settings above Troubleshooting The following sections describe common problems, with possible solutions, which can occur with your Intel® Storage Server SSR212MC2/SSR212MC2R. For details on how to remove and replace a module see Section “Hardware Installations and Upgrades” on page...
  • Page 150 3. Fan LED is illuminated. 3. Reduce the ambient temperature. Thermal Control The Intel® Storage Server SSR212MC2/SSR212MC2R uses extensive thermal monitoring to ensure component temperatures are kept low and acoustic noise is minimized. Airflow is from front to rear of the enclosure.
  • Page 151 • If the subsystem is powered up and you remove any module, replace it immediately. If the subsystem is used with modules or module blanks missing for more than a few Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 152 Depending on how the enclosure system is set up, if a disk unit fails, it can normally be replaced without interrupting the use of the system. If an enclosure contains two PSUs, either PSU can maintain power to the system while the other is being replaced. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 153 Upgrading Component Firmware or the Server Board BIOS ® ® If replacing an Intel Server Board S5000PSL or Intel RAID Controller SRCSAS144E, refer to the support site at http://www.intel.com/support/motherboards/server/ssr212mc2 for downloading the appropriate firmware or BIOS. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 154 Upgrading Component Firmware Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 155 1 slot 2 D. RMM NIC connector E. PCI Express x4 slot 4 (ROMB F. PCI Express x8 slot 5 slot) G. PCI Express x8 slot 6 H. CMOS battery I. P12V4 connector Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 156 MM. SATA 3 or SAS 1 NN. SATA 4 or SAS 2 OO. SATA 5 or SAS 3 PP. USB port QQ. Front control panel RR. Serial B/emergency SS. Chassis intrusion header header management port header Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 157 2. Press <Ctrl> <G> at bootup when the following screen appears. 3. Once the Intel® RAID BIOS Console starts, a screen will appear displaying the adapter installed in the system. Select the Adapter No. 0 radio button and then click Start.
  • Page 158 Setting up RAID on the Intel® Storage Server SSR212MC2R Create a RAID Volume Note: Refer to the Intel® RAID Controller SRCSAS144E Software User Guide on the Resource CD for a description of applicable RAID levels and logical drive parameters. Note: Refer to the GUI Help files for more information on screen displays.
  • Page 159 Setting up RAID on the Intel® Storage Server SSR212MC2R 6. Select the configuration you wish to set up. (For this example, we selected “Custom Configuration”.) Click Next to continue. 7. Add physical drives to the array by holding the control key while clicking on ready drives.
  • Page 160 Setting up RAID on the Intel® Storage Server SSR212MC2R 8. If desired, define additional arrays. If finished, click Accept DG. Click Next to continue. 9. Select the RAID Level from the pull-down box. Enter in the size of the logical drive.
  • Page 161 Setting up RAID on the Intel® Storage Server SSR212MC2R 10. Click Accept. 11. Click Yes when asked to save the configuration. 12. Click Yes when asked to initialize the new logical drives. Depending on drive size and RAID level, initialization can take many hours to complete.
  • Page 162 Setting up RAID on the Intel® Storage Server SSR212MC2R Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 163 Therefore, software RAID on the 12 drives connected to the backplane is not supported. Software RAID is only supported on the boot drives. 1. Boot the system. 2. Press <Ctrl> <E> when prompted to start the Intel® Embedded Server RAID BIOS Configuration utility. Create a RAID Volume 3.
  • Page 164 Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 4. Select New Configuration and answer “yes” when prompted to proceed. The Array Selection Menu will be displayed. 5. Use the arrow keys to navigate to a drive. Press the space bar to add the selected drive to an array.
  • Page 165 Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 7. Repeat Steps 5 and 6 to create a second array if desired. Press <F10> when finished with creating all arrays. 8. Select an array by highlighting it and pressing the space bar. Press <F10> to configure the properties for the array.
  • Page 166 Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 9. The Logical Drives Configured screen will be displayed. This screen shows the: — Logical drive number — RAID level — Logical drive size — Number of stripes in the physical array —...
  • Page 167 Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 13. When you have finished defining the current logical drive, select Accept and press Enter. The Array Selection Menu screen will be displayed. 14. Repeat Steps 8 through 13 for all logical drives.
  • Page 168 Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 15. Select the array you just configured. Select “yes” when prompted to Save the configuration. Press ESC to return to the main menu. 16. Select Initialize. Caution: All data on the logical drive will be erased during an initialization.
  • Page 169 Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 Use the space bar to highlight the logical drive to initialize. 17. Press F10. Select Yes at the prompt and press Enter to begin the initialization. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 170 Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 18. A graph will appear showing progress of the initialization. 19. After the initialization is complete, press ESC to return to the previous menu. 20. Press ESC to return to the management menu.
  • Page 171 Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 22. Reboot the system by pressing <Ctrl> <Alt> <Del>. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 172 Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 173 RAID 0 usually denotes two or more drives. RAID 0 ABCDEF Available Capacity RAID Adapter N=# disks C = Disk Capacity Available Capacity = N*C Data Striping RAID 0 Figure 141. RAID 0 - Data Striping Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 174 RAID 5 ABCDEF Available Capacity RAID Adapter N=# disks C = Disk Capacity Available Capacity = Data Striping & (N*C)(N-1) /N Striped Parity RAID 5 Figure 143. RAID 5 - Data Striping with Striped Parity Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 175 Available Capacity RAID Adapter N=# disks C = Disk Capacity Available Capacity = (N*C) /2 Disk Mirror & Data Striping RAID 10 Figure 144. RAID 10 - Combination of RAID 1 and RAID 0 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 176 RAID Adapter N=# disks C = Disk Capacity Available Capacity = (N*C)(N-1) /N P1(B+D) P(F+H) P(J+L) RAID 5 & Data Striping RAID 50 Figure 145. RAID 50 - Combination of RAID 5 and RAID 0 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 177 Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). Before calling, fill out an “Intel®...
  • Page 178 Colombia ... Contact AT&T USA at 01 800 911 0010. Once connected, dial 800 843 4481 Costa Rica . Contact AT&T USA at 0 800 0 114 114. Once connected, dial 800 843 4481 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 179 Panama..Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481 Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 180 Getting Help Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 181 (or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.
  • Page 182 This product has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed in a compatible Intel® host system. For information on compatible host system(s) refer to Intel's Server Builder Web site or contact your local Intel representative.
  • Page 183 MED Declaration of Conformity (New Zealand) • BSMI Certification (Taiwan) • GOST R Certification / Certification (Russia) • Belarus Certification / Certification (Belarus) • RRL Certification (Korea) • IRAM Certification (Argentina) • CNCA Certification (China) Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 184 VCCI Marking (Class A) Japan BSMI Certification Taiwan Number & Class A Warning GOST R Marking Russia RRL MIC Mark Korea See the regulatory information document for additional information. China Compulsory China Certification Mark Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 185 Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment to an outlet on a circuit other than the one to which the receiver is connected. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 186 This product has been tested in accordance to, and complies with the Low Voltage Directive (73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to illustrate its compliance. VCCI (Japan) Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 187 Following is the RRL certification information for Korea. English translation of the notice above: 1. Type of Equipment (Model Name): On Certification and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4.
  • Page 188 Special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate. This notice is required by California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product/part includes a battery which contains perchlorate material. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 189 Restriction of Hazardous Substances (RoHS) Compliance Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration that materials banned in the RoHS Directive are either (1) below all applicable threshold limits or (2) an approved / pending RoHS exemption applies.
  • Page 190 End of Life / Product Recycling Product recycling and end-of-life take back systems and requirements vary from country to country. Contact the retailer or distributor of this product for information on product recycling and / or take back. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 191 "as is" unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
  • Page 192 Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
  • Page 193 Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
  • Page 194 Warranty Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 195 To do this: 1. Unlock and remove the padlock from the back of the system if a padlock has been installed. 2. Remove and save all screws from the covers. 3. Remove the cover(s). Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 196 • Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 197 Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 198 Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 199 Telekommunikationsleitungen mit dem Modem bestehen; • "mit einer geerdeten Wechselstromsteckdose ausgerüstet sein; • "über ausreichend Platz verfügen, um Zugang zu den Netzkabeln zu gewährleisten, da der Stromanschluß des Produkts hauptsächlich über die Kabel unterbrochen wird Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 200 Procédez comme suit: 1. Si un cadenas a été installé sur à l'arrière du système, déverrouillez-le et retirez-le. 2. Retirez toutes les vis des panneaux et mettez-les dans un endroit sûr. 3. Retirez les panneaux. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 201 • "Muni d'une prise murale correctement mise à la terre. • "Suffisamment spacieux pour vous permettre d'accéder aux câbles d'alimentation (ceux-ci étant le seul moyen de mettre le système hors tension). Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 202 Para ello: 1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos de las tapas.Extraiga las tapas. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 203 • "Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 204 1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 205 • "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 206 Installation/Assembly Safety Instructions Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 207 To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in ® this guide before installing or maintaining your Intel storage server. In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.
  • Page 208 AC power, 5V standby power is active whenever the system is plugged in. To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 209 Turn off all peripheral devices connected to this product. • Turn off the system by pressing the power button to off. • Disconnect the AC power by unplugging all AC power cords from the system or wall outlet. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 210 Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 211 Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 212 Safety Information Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, bevor Sie Ihr Intel®...
  • Page 213 • Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 214 Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
  • Page 215 Einbauen von Hot-Plug-Komponenten sorgfältig vor, um nicht mit heißen Komponenten in Berührung zu kommen. Vorsicht: Berühren Sie nicht die rotierenden Lüfterflügel, um Verletzungen zu vermeiden. Falls Ihr System mit eine Lüfterabdeckung besitzt, darf es nicht ohne diese Abdeckung betrieben werden. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 216 Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 217 Vorsicht: Beachten Sie zur Vermeidung von Strahlung und Verletzungen die folgenden Hinweise: • Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 218 Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant...
  • Page 219 • Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 220 Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
  • Page 221 Attention: Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre système est fourni avec une protection sur le ventilateur, ne mettez pas le système en route sans la protection en place. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 222 à la terre, exempte de charge statique, composants orientés vers le haut. Utilisez si possible un tapi de mousse conducteru, mais pas l’emballage de la carte. Veillez à ce que la carte ne glisse sur aucune surface. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 223 Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au fabricant en cas de problème. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 224 Safety Information Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , las carcasas de servidor de ® Intel (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento...
  • Page 225 Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 226 CA estén desenchufado antes de abrir la carcasa, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precauciónes al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
  • Page 227 Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 228 Utilice una almohadilla de espuma conductora si dispone de ella, pero nunca el envoltorio de la tarjeta. No deslice la tarjeta sobre ninguna superficie. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 229 Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 230 表示如果无视此 “ ? ? ? 项 ” ? ? ? ? ? ? ? 轻微人身伤害或财产损失的危险。 警告 表示如果无视此 “ ? ? ” ? ? ? ? ? ? ? 严重人身伤害的危险。 表示如果无视所示信息,即存在潜在的危险。 表示如果不遵守安全指导,存在可导致严重伤害或死亡的电击危险。 表示灼热组件或表面。 表示请勿触摸风机叶片,否则可能致伤。 表示拔下所有交流电线,断开交流电源 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 231 通风良好,远离热源(包括直接日晒和散热器)。 • 远离振动源或物理震动。 • 与电气设备产生的强大电磁场隔离。 • 在易受闪电袭击的地区,我们建议将系统插入电涌抑制器并在闪电期间断开通信 线路与调制解调器之间的连接。 • 提供正确接地的墙壁插座。 • 提供足够的空间,以便拿取电源供应线,因为这是本产品的主要电源断开器。 设备操作规范 减少人身伤害或设备受损的危险: • 移举设备时遵守当地的职业健康与安全要求。 • 借助机械手段或其他合适的手段移举设备。 • 拆除一切易分离组件,以降低重量并方便操作。 电源与电气警告 注意事项 电源按钮(如待机电源标记所示)并不能完全关闭系统的交流电源,只要系统已接 通电源,就存在 5V 待机电源。要从系统切断电源,须从墙壁电源插座中拔下交流电线。您的系统可能 不止使用一根交流电线。请确保所有的交流电线都已拔下。打开机箱或增加或去除 任何热插拔组件之前,确保交流电线已拔下。 若非所需的确切类型,请勿尝试修改或使用交流电线。系统的每个电源供应设备都 需要一根单独的交流电线。 本产品的电源供应设备包含非用户维修部件。请勿打开电源供应设备。电源供应设 备包含非常危险的电压级、电流级和能量级。请与生产商联系维修事宜。 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线,再将其 从服务器上移除。 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 232 ⎯ 电源线的电气额定值须大于产品上标注的电流额定值。 ⎯ 电源线须拥有适合插座的安全接地插头或触点。 • 电源线为交流电源的主要断开设备。插座须靠近设备并可随时断开。 • 电源线须插入所提供的拥有合适接地的插座。 系统使用警告 注意事项 为避免人身伤害或财产损失,无论何时检查产品内部,以下安全指导都适用: • 关闭所有与本产品相连的外设。 • 按下电源按钮至关闭状态,关闭系统。 • 从系统或墙壁插座上拔下所有交流电线,断开交流电源。 • 断开与系统相连的所有线缆和通信线路。 • 卸除舱口盖时,保留所有螺钉及其他紧固件。完成产品内部检查之后,请 用螺钉或紧固件重新固定舱口盖。 • 请勿打开电源供应设备。电源供应设备内没有可维修部件。请与生产商联系 维修事宜. • 增加或替换任何非热插拔组件之前,请关闭服务器电源并断开所有电源线 。 • 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线 ,然后再从服务器上移除电源供应设备。 注意事项 如果服务器一直在运行,任何已安装的处理器和吸热设备都可能很热。除非要增加 或移除热插拔组件,否则请待系统冷却后再开盖。为避免在热插拔组件安装过程中 接触灼热组件,移除或安装热插拔组件时务须小心。 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 233 Safety Information 注意事项 为避免受伤,请勿触摸运转的风机叶片。如果系统的风机上配有防护装置,请勿卸 下风机防护装置运行系统。 机架固定件警告 设备的机架须固定在稳固的支座上,以防从中安装服务器或设备时倒塌。须按照机 架生产商提供的安装说明进行安装。 从下往上将设备安装在机架上,最重的设备安装在机架的最底层。 一次只从机架上安装一件设备。 您须负责安装整个机架装置的主要电源断开设备。此主要断开设备须随时可用,且 须标明为控制整个装置(而不仅限于服务器)的电源。 为避免潜在的电击危险,须对机架及其上所安装的每一件设备实行正确的安全接地 。 静电放电 (ESD) 注意事项 ESD 会损坏磁盘驱动器、主板及其他部件。我们建议您执行 ESD 工作站的所有步骤。如果没有 ESD 工作站,则采取一些静电放电保护措施,操作部件时,戴上与服务器上的机箱接地 或任何未喷漆金属表面连接的防静电腕带。 操作主板时始终保持小心。它们可能对 ESD 非常敏感。拿持主板时只接触边缘。从保护包装中或从服务器上取出主板后,请将 主板组件侧面朝上放置在无静电的接地表面上。请使用导电泡沫垫(若有),不要 使用主板包装。请勿将主板在任何表面上滑动。 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 234 Safety Information 其他危险 替换电池 注意事项 不正确替换电池可能导致爆炸危险。替换电池时,请只使用设备生产商推荐使用的 电池。 请按当地法规处置电池。 请勿对电池充电。 请勿拆卸、刺穿或以其他方式损坏电池。 冷却和气流 注意事项 按照说明小心布置线缆,尽量减少气流阻塞和冷却问题。 为保证适当的冷却和气流,运行系统时请确保机箱盖已安装。未安装机箱盖即运行 系统可能导致系统部件受损。安装机箱盖的步骤如下: 首先检查并确保系统内没有遗留的未固定工具或部件。 • 检查线缆、内插板和其他组件已正确安装。 • 按产品说明安装机箱盖。 • 激光外设或激光设备 注意事项 为避免幅射暴露和 / 或人身伤害: 请勿打开任何激光外设或激光设备的外壳 • 激光外设或激光设备为非用户维修设备 • 请与生产商联系维修事宜 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
  • Page 235 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Intel FMCFANS...

This manual is also suitable for:

Ssr212mc2rSsr212mc2