Storage system
power distribution module (fmjpdb) (23 pages)
Summary of Contents for Intel D90842-002
Page 1
Intel® Storage Server SSR212MC2/ SSR212MC2R User Guide ® A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number D90842-002...
Page 2
Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
Page 3
Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http://support.intel.com/support/motherboards/server/sb/cs- 010770.htm. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor...
Page 4
Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 5
Preface About this Manual Thank you for purchasing and using the Intel® Storage Server SSR212MC2/ SSR212MC2R. This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this storage system. This document provides a brief overview of...
Page 6
Hardware (peripheral Tested Hardware Operating Systems List boards, adapter cards) and operating systems that have been tested with this product For software to manage StorView* Enclosure Management Software ® your Intel storage system Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 7
Preparation of Site and Host Server ..................17 Unpacking the Enclosure System ..................... 17 Planning and Configuring Your Installation ................17 Rack Installation Prerequisites ....................18 Installing the Enclosure in a Rack ..................18 Rail Kit Assembly ........................19 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 8
Removing and Installing the Processor Air Duct ..............44 Removing the Processor Air Duct .................... 44 Installing the Processor Air Duct ....................45 Installing and Removing Memory ..................45 Installing FBDIMMs ........................45 viii Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 9
Replacing a Server Board ....................97 Replacing the SAS Expander PCB ..................107 Replacing an Intel® RAID Controller SRCSAS144E ............110 Replacing the Intel® Intelligent AXXRIBBU1 Battery Backup Unit ........112 Installing the Boot Drives ....................115 Installing an Add-in Board ....................122 Troubleshooting and Problem Solving ..............125 Overview ..........................125...
Page 10
C Setting up RAID on the Intel® Storage Server SSR212MC2R ......139 Enter RAID BIOS Console ....................139 Create a RAID Volume ...................... 140 D Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 Start RAID Configuration Utility ..................145 Create a RAID Volume ...................... 145 E RAID Levels ......................155...
Page 11
Restriction of Hazardous Substances (RoHS) Compliance ..........171 End of Life / Product Recycling ..................172 H Warranty ......................173 Limited Warranty for Intel® Chassis Subassembly Products ..........173 Extent of Limited Warranty ....................173 Warranty Limitations and Exclusions .................174 Limitations of Liability ......................174 How to Obtain Warranty Service ....................
Page 12
Advertencias y precauciones sobre seguridad ............... 206 Aplicaciones y usos previstos ....................207 Selección de la ubicación ....................... 207 Manipulación del equipo ......................207 Advertencias el acceso al sistema ..................209 Descarga electrostática (ESD) ....................210 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 13
List of Figures List of Figures Figure 1. Intel® Storage Server SSR212MC2/SSR212MC2R - Front View....... 1 Figure 2. Intel® Storage Server SSR212MC2/SSR212MC2R - Rear View Showing Service Ar- eas............................2 Figure 3. Rear View........................3 Figure 4. Front View ........................4 Figure 5.
Page 14
Figure 96. Re-installing Brace Assembly ................. 88 Figure 97. Removing Brace Assembly..................90 Figure 98. Removing Boot Drive Module ................. 90 Figure 99. Locating IDE Connector on the Server Board ............91 Figure 100. Removing IDE DOM ..................... 91 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 15
Figure 127. Removing Battery Assembly from Battery Backup Unit ........113 Figure 128. Attaching Battery to Battery Backup Unit ............114 Figure 129. Installing the New Intel® Intelligent AXXRIBBU1 Battery Backup Unit ....114 Figure 130. Removing Brace Assembly ................. 115 Figure 131.
Page 16
List of Figures Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 18
List of Tables xviii Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 19
Storage Server Features The Intel® Storage Server SSR212MC2/SSR212MC2R is a 2U (rack space) disk drive enclosure, currently housing twelve low-profile (1-in high), 1.5/3.0 Gb/s, 3.5-in form factor SAS/SATA disk drives. Each individual disk drive is field replaceable. Figure 1 shows a front view of the Intel® Storage Server SSR212MC2/SSR212MC2R...
Page 20
D. Boot Drive E. Server Board F. PCI Slots Enclosure Core Product The Intel® Storage Server SSR212MC2/SSR212MC2R design concept is based on an enclosure sub-system together with a set of plug-in modules and (as supplied) consists of: • An enclosure chassis with: —...
Page 21
Note: If only one PSU is installed, a blanking plate must be fitted over the empty upper bay. • A server subsystem comprising: — An Intel® Server Board S5000PSL with integral I/O panel — An Intel® RAID Controller SRCSAS144E — An Intel® Intelligent AXXRIBBU1 Battery Backup Unit — A boot drive module •...
Page 22
Figure 4. Front View Enclosure Chassis Figure 5. Enclosure Chassis The enclosure chassis consists of a sheet metal enclosure assembly containing an integrated backplane printed circuit board (PCB), an enclosure management PCB, and a module runner system. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 23
Slots for up to six low-profile 3/4-length PCI cards, installed in a vertical orientation.The following PCBs are installed as standard configuration: — (SSR212MC2R only) An Intel® RAID Controller SRCSAS144E, in the left-hand slot (when viewed from the rear) — (SSR212MC2R only) An Intel® Intelligent AXXRIBBU1 Battery Backup Unit, in the right-hand slot (when viewed from the rear) Blank PCI plates are filled in the empty PCI slots.
Page 24
• PS2 mouse port • PS2 keyboard port • Serial port • Video port • Two RJ-45 ports - NICs 1 and 2 (1Gb each) • Four USB ports: 0, 1, 2, and 3 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 25
Storage Server Features Server Board LEDs See your Intel® Server Board S5000PSL User Guide for full details on I/O panel LED states. Status LEDs Diagnostic LEDs are present on the server board I/O panel to assist in identifying failed and failing components. See “Server Board LEDs”...
Page 26
Used to identify a server from among several servers Power Supply Unit AC-DC power is provided by a commercial dual-redundant power supply with specific load capability, mechanical packaging and output loom to suit this product. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 27
(green/red) LED to indicate PSU status. Multiple Power Supply Units The Intel® Storage Server SSR212MC2/SSR212MC2R can be operated with either one or two PSUs fitted in the power supply mounting cage. If two PSUs are fitted, they provide redundancy for the system so that if one PSU fails the other maintains the power supply while the faulty PSU is being replaced.
Page 28
The cooling cage contains ten individual high-speed single-rotor axial fans, individually connected to and interfacing with the enclosure management PCB. This interface provides power and speed control to the fans and returns tacho output from each fan to the management system. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 29
LED) mounted on the front cap of each drive carrier module. See “Disk Drive LEDs” on page 24 for a description of LED states. A. Green LED B. Amber LED C. Torque Screw D. Drive Lock Indicator Aperture Figure 12. Drive Status LEDs and Components Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 30
Warning: Operation of the enclosure with ANY modules missing will disrupt the airflow and the drives will not receive sufficient cooling. Spare Parts and Accessories The following replaceable parts are available for the Intel® Storage Server SSR212MC2/ SSR212MC2R. Table 3. Spare Parts and Accessories...
Page 31
Hot swap fans (5 pack) FMCSASX SAS expander card FMCAIRBAFFLE Processor and memory air ducts BB5000PSLSAS 10-pack of Intel® Server Board S5000PSL with integrated 4-port SRCSAS144E 10-pack of Intel® RAID Controller SRCSAS144E AXXRIBBU1 Intel® Intelligent AXXRIBBU1 Battery Backup Unit AMC850WPS...
Page 32
Storage Server Features Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 33
Getting Started In this chapter, you are shown how to plan and install your Intel® Storage Server SSR212MC2/SSR212MC2R into an industry standard 19-inch rack cabinet. Caution: When connecting up the Intel® Storage Server SSR212MC2/SSR212MC2R, use only the power cords supplied or power cords which match the specification quoted in “Power...
Page 34
1 x 4 bay bank would take the space of one drive width by four drive bays across (in the rack mount configuration). The Intel® Storage Server SSR212MC2/SSR212MC2R subsystem is housed in a 4 x 3 enclosure, i.e., four drive bays wide by three bays high. The top bays are numbered 1 to 4 from left to right, as viewed from the front.
Page 35
Getting Started Preparation of Site and Host Server Before beginning, make sure that the site where you intend to set up and use your Intel® Storage Server SSR212MC2/SSR212MC2R has standard AC power available from an independent source or a rack power distribution unit with a UPS (universal power supply).
Page 36
Installing the Enclosure in a Rack A set of rack-mounting rails is provided with the system for installing the Intel® Storage Server SSR212MC2/SSR212MC2R in a 19-inch rack cabinet. These rails have been designed and tested to handle the maximum weight of the enclosure and to ensure that multiple enclosures may be installed without loss of space within the rack.
Page 37
Getting Started Rail Kit Assembly Refer to the Rail Kit Install Guide: Intel® Storage Server SSR212MC2/SSR212MC2R for instructions on assembling the rail kit. A. Rear Rack Post B. Clamping Screws C. Rack Bracket ASM D. Front Rack Post E. Slide Screw (4) F.
Page 38
The Intel® Storage Server SSR212MC2/SSR212MC2R is delivered with backplane PCB, server board, enclosure management PCB, SAS expander PCB, Front Operator’s Panel, and all plug-in modules pre-installed. The Intel® Storage Server SSR212MC2R also ships with an Intel® RAID Controller SRCSAS144E and an Intel® Intelligent AXXRIBBU1 Battery Backup Unit pre-installed.
Page 39
Power On Caution: Do not operate the Intel® Storage Server SSR212MC2/SSR212MC2R until the ambient temperature is within the specified operating range. If the drives have been recently installed, ensure they have had time to acclimate before operating them.
Page 40
Functions of the push-button switches are defined in Table A. USB Port B. Power Active LED C. Unit Fault LED D. ID LED E. On/Off Switch F. Reset Button (recessed) G. ID LED Activation Switch Figure 17. Front Operator’s Panel Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 41
There may be a power problem (an alarm and power fault indication would normally be present). • In the presence of only one PSU, the drive motors will spin up in a delayed sequence. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 42
To power down the enclosure, either: • Switch off the PSU(s) installed in the enclosure by pressing the power push-button on the Front Operator’s Panel for approximately 3 seconds, • Remove AC mains at the power source. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 43
This chapter provides instructions for removing, installing, and replacing storage system components in your Intel® Storage Server SSR212MC2/SSR212MC2R. Caution: When connecting the Intel® Storage Server SSR212MC2/SSR212MC2R to a power source, use either the power cords that shipped with the system, or match the power cord specifications listed under “Power Cord”...
Page 44
— Access to power supply unit openings Upon replacement, the cover MUST be secured by tightening the retaining screw with a screwdriver. Removing the Enclosure Cover 1. Observe all safety and ESD precautions listed in “Safety Information” on page 189. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 45
(see letter “B”) and slide the enclosure cover back (see letter “C”) until it stops. Figure 18. Unlatching Enclosure Cover 3. Lift the cover to completely remove it from the chassis. Figure 19. Removing Enclosure Cover Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 46
A PSU can be replaced if it fails. If your storage system uses a redundant power supply system, you do not need to power down the system to replace the failed PSU as long as the remaining PSU is plugged into an AC power source and is functioning. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 47
3. For redundant PSU systems, make sure you correctly identify the faulty PSU to be replaced. 4. Switch off and disconnect the power supply bail. Disconnect the power supply cord to the faulty PSU. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 48
5. Press the locking tab to the left. Figure 21. Unlatching a Power Supply Unit 6. Grip the handle and withdraw the PSU from the mounting cage. Figure 22. Removing a Power Supply Unit Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 49
2. Check for damage to the new PSU, especially to the rear connector on the module. 3. Slide the PSU into the mounting cage. A click should be heard as the securing spring engages. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 50
Figure 24. Power Supply Unit in Place 4. Connect the AC power cable to the new PSU. Secure the power cord plug with the power supply bail. 5. On non-redundant power supply systems, power up the storage system. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 51
“EARTH LEAKAGE CURRENT” (“TOUCH CURRENT”). Prior to switching on, ensure that the earth connection to the rack has been checked by an electrical engineer qualified in local and national electrical standards. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 52
Hardware Installations and Upgrades Replacing a Cooling Fan The Intel® Storage Server SSR212MC2/SSR212MC2R has ten fans in its cooling cage to ensure proper cooling of the system. Each cooling fan can be individually replaced. Warning: The enclosure cover should only be removed by qualified service personnel as it provides access to a service area.
Page 53
3. Grip the faulty fan with finger and thumb and pull it upwards to unplug it from the enclosure management PCB. Remove fan from the enclosure. Figure 27. Removing a Cooling Fan 4. Check the new fan for damage. Do not install it if there are any visible signs of damage. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 54
PCB. Ensure that the fan LED extinguishes within 10 seconds of installation. Figure 28. Installing a Cooling Fan 6. Close the enclosure cover and latch securely by turning the lock mechanism to the “locked” position. Figure 29. Re-installing Enclosure Cover Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 55
“De-activating an Anti-tamper Lock” on page 41 for instructions on de-activating the lock. 3. Release the carrier handle by pressing the latch in the handle towards the handle hinge. Figure 30. Unlatching a Drive Carrier Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 56
1. Observe all safety and ESD precautions listed in “Safety Information” on page 189. 2. Release the drive carrier handle by depressing the latch in the handle. Figure 32. Unlatching a Drive Carrier Handle Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 57
5. Cam the drive carrier home until the camming foot on the base of the drive carrier engages with the enclosure. Continue to push firmly until the handle fully closes. A click should be heard as the latch engages and holds the handle closed. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 58
1. Carefully insert the TORX* screwdriver provided into the cutout in the handle (see letter “A” in the following figure). 2. Rotate the screwdriver in a clockwise direction until the lock symbol is visible in the aperture beside the key (see letter “B”). Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 59
(see letter “B”). Note: Do not turn the lock more than half a turn otherwise the drive carrier may be damaged. Figure 37. De-activating an Anti-tamper Lock 3. Remove the screwdriver. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 60
5. For instructions on re-installing the drive carrier into the drive bay, see “Installing a Drive Carrier Module” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 61
(see letter “B”). Set any jumpers for the hard drive. Figure 39. Installing Hard Drive into Drive Carrier 5. For instructions on re-installing the drive carrier into the drive bay, see “Installing a Hard Drive into a Drive Carrier” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 62
5. Lift the processor air duct from its location over the processor sockets. Figure 40. Removing the Processor Air Duct 6. If removing a processor air duct as part of another procedure, continue with that procedure. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 63
Caution: Before performing any maintenance on the system, back up the data. Follow the instructions in the operating system manual for shutting down the system. Warning: Do not operate the Intel® Storage Server SSR212MC2/SSR212MC2R without the presence of a processor air duct.
Page 64
5. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page 6. Locate the DIMM sockets. Callout DIMM Socket Callout DIMM Socket DIMM_A1 DIMM_C1 DIMM_A2 DIMM_C2 DIMM_B1 DIMM_D1 DIMM_B2 DIMM_D2 Figure 42. Locating FBDIMM Sockets Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 65
3. Disconnect the AC power cord(s). 4. Remove the enclosure cover. For instructions, see “Removing the Enclosure Cover” on page 5. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 66
“Installing the Processor Air Duct” on page 10. Re-install the enclosure cover. For instructions, see “Installing the Enclosure Cover” on page 11. Reconnect all peripheral devices and the AC power cord(s). Power up the storage system. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 67
Intel® Storage Server SSR212MC2/SSR212MC2R. Caution: Reduce the risk of ESD damage to the processor by doing the following: (1) Touch the metal chassis before touching the processor or server board. Keep part of your body in contact with the metal chassis to dissipate the static charge while handling the processor.
Page 68
Hardware Installations and Upgrades 6. Locate the processor sockets. Callout Processor Socket Callout Processor Socket CPU_2 CPU_1 (Use this socket when installing a single processor.) Figure 45. Locating Processor Sockets Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 69
Fully open the load plate. Figure 47. Opening Load Plate 9. If the protective cover is attached to the load plate, remove it and store it for future use. Figure 48. Removing Protective Cover from Load Plate Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 70
14. Prepare the passive heatsink for installation. The heatsink has thermal interface material (TIM) located on the bottom of it. Use caution when handling the heatsink so as not to damage the TIM. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 71
In the same order, gradually and equally tighten each captive screw until all are firmly tightened. Do not fully tighten one screw at a time. Figure 50. Installing Passive Heatsink Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 72
2. Turn off all peripheral devices connected to the storage system. Power down the storage system. 3. Disconnect the AC power cord(s). 4. Remove the enclosure cover. For instructions, see “Removing the Enclosure Cover” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 73
CPU_2 CPU_1 Figure 52. Locating Processor Sockets 7. Loosen the four captive screws on the corners of the heatsink. 8. Twist the heatsink slightly to break the seal between the heatsink and the processor. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 74
Figure 53. Opening Processor Socket Lever 11. Push down on the rear tab of the load plate to swing the front of the load plate up slightly. Fully open the load plate. Figure 54. Opening Load Plate Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 75
17. Re-install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page 18. Re-install the enclosure cover. For instructions, see “Installing the Enclosure Cover” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 76
4. Remove the enclosure cover. For instructions, see “Removing the Enclosure Cover” on page 5. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page 6. Locate the CMOS battery. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 77
“Installing the Enclosure Cover” on page 13. Reconnect all peripheral devices and the AC power cord(s). Power up the storage system. 14. Run the BIOS Setup utility to restore the configuration settings to the real-time clock. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 78
See the Intel® Server Board S5000PSLUser Guide for information on setting up the server board to support either SATA or SAS options. In the Intel® Storage Server SSR212MC2, the two internal boot drives are connected to the two black SATA ports and can be used with SATA drives.
Page 79
Port USB port on connected to server board backplane via mini-SAS to 4x SATA Table 8. Intel® Storage Server SSR212MC2 Boot Drive SAS/SATA Cable Connections Server Board SATA Boot Drive SAS Boot Drive DOM Boot Drive Connector (as shipped) SATA 0...
Page 80
“Setting up RAID on the Intel® Storage Server SSR212MC2R” on page 139 information on setting up RAID 0 or RAID 1 options using these boot drives. The twelve drives connected to the storage system backplane are controlled by the Intel® RAID Controller SRCSAS144E. See the Intel® RAID Controller SRCSAS144E Software User Guide and Hardware Guide for information on configuring RAID options.
Page 81
Hardware Installations and Upgrades Table 9. Intel® Storage Server SSR212MC2R Boot Drive Cable Connections Boot Drive Mini-USB P4 Power 12 SAS/SATA Boot Drives Options Cable Cable Drives SAS/SATA Connected to Connected to SAS 0 connected Intel® RAID drives on boot...
Page 82
Hardware Installations and Upgrades Replacing or Installing a SATA DOM The Intel® Storage Server SSR212MC2/SSR212MC2R can be used with a Disk On Module (DOM) installed directly to the server board’s SATA 0 Port. A SATA DOM is a storage device based on flash memory technology, which emulates an ordinary magnetic hard drive.
Page 83
Figure 58. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 59. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 84
9. Press in on the latch on the side of the DOM (see letter “A” in the following figure) to release DOM from connector. Lift DOM off the connector (see letter “B”). Remove the power cable from the DOM (see letter “C”). Figure 61. Removing SATA DOM Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 85
11. Align the two holes at the back of the boot drive module with the two chassis pins. Push until seated properly. Secure the boot drive module to the chassis with the single screw previously removed. Figure 63. Re-installing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 86
Installing a SATA DOM See the documentation supplied by your vendor for more information on how to upgrade the Intel® Storage Server SSR212MC2/SSR212MC2R to use third-party software. 1. Observe all safety and ESD precautions listed in “Safety Information” on page 189.
Page 87
Figure 65. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 66. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 88
9. Connect the P4 power cable to the power adapter cable that came with the new SATA DOM. 10. Locate the SATA Port 0 on the server board (see letter “A” in the following figure). Figure 68. Locating SATA Port 0 on Server Board Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 89
12. Align the two holes at the back of the boot drive module with the two chassis pins. Push until seated properly. Secure the boot drive module to the chassis with the single screw previously removed. Figure 70. Re-installing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 90
Replacing or Installing a USB Header DOM The Intel® Storage Server SSR212MC2/SSR212MC2R can be used with Disk On Module (DOM) installed directly to the server board’s USB header. A USB DOM is a storage device based on flash memory technology, which emulates an ordinary magnetic hard drive.
Page 91
3. Disconnect the AC power cord(s). 4. Remove the enclosure cover. For instructions, see “Removing the Enclosure Cover” on page 5. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 92
Figure 72. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 73. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 93
9. Press in on both sides of the USB Header DOM (see letter “A” in the following figure) and pull up to remove from the USB header (see letter “B”). Figure 75. Removing USB Header DOM Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 94
11. Align the two holes at the back of the boot drive module with the two chassis pins. Push until seated properly. Secure the boot drive module to the chassis with the single screw previously removed. Figure 77. Re-installing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 95
Installing a USB Header DOM See the documentation supplied by your vendor for more information on how to upgrade the Intel® Storage Server SSR212MC2/SSR212MC2R to use third-party software. 1. Observe all safety and ESD precautions listed in “Safety Information” on page 189.
Page 96
Figure 79. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 80. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 97
Figure 81. Disconnecting Power and Disk Drive Cables from Boot Drive Module 9. Locate the USB header on the server board (see letter “A” in the following figure). Remove the mini USB cable. Figure 82. Locating USB Header on the Server Board Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 98
11. Align the two holes at the back of the boot drive module with the two chassis pins. Push until seated properly. Secure the boot drive module to the chassis with the single screw previously removed. Figure 84. Re-installing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 99
“Installing the Processor Air Duct” on page 14. Re-install the enclosure cover. For instructions, see “Installing the Enclosure Cover” on page 15. Reconnect all peripheral devices and the AC power cord(s). Power up the storage system. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 100
Hardware Installations and Upgrades Replacing or Installing a USB Flash Drive The Intel® Storage Server SSR212MC2/SSR212MC2R can be used with a USB Flash Drive installed directly to the server board’s USB port. A USB Flash Drive is a storage device based on flash memory technology, which emulates an ordinary magnetic hard drive.
Page 101
Figure 86. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 87. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 102
11. Align the two holes at the back of the boot drive module with the two chassis pins. Push until seated properly. Secure the boot drive module to the chassis with the single screw previously removed. Figure 89. Re-installing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 103
Installing a USB Flash Drive See the documentation supplied by your vendor for more information on how to upgrade the Intel® Storage Server SSR212MC2/SSR212MC2R to use third-party software. 1. Observe all safety and ESD precautions listed in “Safety Information” on page 189.
Page 104
Figure 91. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 92. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 105
Figure 93. Disconnecting Power and Disk Drive Cables from Boot Drive Module 9. Locate the USB port on the server board (see letter “A” in the following figure). Figure 94. Locating USB Port on the Server Board Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 106
12. Re-install the brace assembly (see letter “A” in the following figure). Secure to enclosure by tightening the two captive screws (see letter “B”). Figure 96. Re-installing Brace Assembly 13. Re-install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 107
Replacing or Installing an IDE DOM The Intel® Storage Server SSR212MC2/SSR212MC2R can be used with a Disk On Module (DOM) installed directly to the server board’s IDE connector. An IDE DOM is a storage device based on flash memory technology, which emulates an ordinary magnetic hard drive.
Page 108
Figure 97. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 98. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 109
Ensure the latches are closed enough for easy removal of the IDE DOM otherwise the housing on the IDE connector may be damaged. Disconnect the power cable from the IDE DOM (see letter “B”). Figure 100. Removing IDE DOM Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 110
11. Align the two holes at the back of the boot drive module with the two chassis pins. Push until seated properly. Secure the boot drive module to the chassis with the single screw previously removed. Figure 102. Re-installing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 111
Installing an IDE DOM See the documentation supplied by your vendor for more information on how to upgrade the Intel® Storage Server SSR212MC2/SSR212MC2R to use third-party software. 1. Observe all safety and ESD precautions listed in “Safety Information” on page 189.
Page 112
Figure 104. Removing Brace Assembly 7. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 105. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 113
9. Connect the P4 power cable to the power adapter cable that shipped with the new IDE DOM. 10. Locate the IDE connector on the server board (see letter “A” in the following figure). Figure 107. Locating IDE Connector on the Server Board Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 114
12. Align the two holes at the back of the boot drive module with the two chassis pins. Push until seated properly. Secure the boot drive module to the chassis with the single screw previously removed. Figure 109. Re-installing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 115
Caution: Back up the data on the storage system before performing any maintenance procedures. Caution: Before installing a new server board, ensure that the server board has the correct versions of the BIOS, FRU/SDR. and mBMC installed. Refer to the Intel support site at http:// www.intel.com/support/motherboards/server/ssr212mc2...
Page 116
Figure 111. Removing Brace Assembly 9. Remove the single screw at the top of the boot drive module and slide the module off the two chassis pins (as shown). Figure 112. Removing Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 117
Power for a USB DOM device is provided by the USB connector. 12. Remove the USB, SATA, or IDE DOM if one is present. For instructions, see the appropriate DOM removal section in this chapter. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 118
SRCSAS144E (see letter “A” in the following figure). Release the screw on the retaining bracket at the back of the enclosure (see letter “B”). Ease the Intel® Intelligent AXXRIBBU1 Battery Backup Unit out of its PCI slot (see letter “C”).
Page 119
SRCSAS144E. Disconnect the SAS cable (see letter “A” in the following figure). Release the screw on the retaining bracket at the back of the enclosure (see letter “B”). Lift the Intel® RAID Controller SRCSAS144E upwards and out of the enclosure (see letter “C”).
Page 120
17. Remove the seven screws securing the server board to the chassis. Remove server board from chassis and store in an anti-static bag. 18. Install the new server board by aligning the screw holes in the server board with the standoffs in the chassis. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 121
— Power cable to the front panel connector, uses pins 11 and 13 (see letter “M”) — Serial B/emergency management port cable (see letter “N”) 22. Re-attach standoff (see letter “O”). Figure 117. Connecting Cables and Standoff to Server Board Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 122
Hardware Installations and Upgrades 23. (Intel® Storage Server SSR212MC2R only) Install the Intel® RAID Controller SRCSAS144E in the leftmost PCI slot (see letter “A” in the following figure). Tighten the screw on the retaining bracket at the back of the enclosure (see letter “B”).
Page 123
AXXRIBBU1 Battery Backup Unit in the rightmost PCI slot (see letter “A” in the following figure). Tighten the screw on the retaining bracket at the back of the enclosure (see letter “B”). Connect the BBU cable to the Intel® RAID Controller SRCSAS144E (see letter “C”).
Page 124
Figure 121. Re-installing Brace Assembly 31. Re-install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page 32. Re-install the enclosure cover. For instructions, see “Installing the Enclosure Cover” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 125
2. Turn off all peripheral devices connected to the storage system. Power down the storage system. 3. Disconnect the AC power cord(s). 4. Remove the enclosure cover. For instructions, see “Removing the Enclosure Cover” on page Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 126
5. Open the PCB cover (see letter “A” in the following figure). Remove the SAS cable (see letter “B”). Pull the SAS Expander PCB assembly forward, unplugging it from the backplane (see letter “C”). Figure 122. Removing the SAS Expander PCB Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 127
Figure 123. Installing the SAS Expander PCB 7. Re-install the enclosure cover. For instructions, see “Installing the Enclosure Cover” on page 8. Reconnect all peripheral devices and the AC power cord(s). Power up the storage system. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 128
Hardware Installations and Upgrades Replacing an Intel® RAID Controller SRCSAS144E The Intel® RAID Controller SRCSAS144E is installed in the left-hand PCI slot (when viewed from the rear) of the Intel® Storage Server SSR212MC2/SSR212MC2R. 1. Observe all safety and ESD precautions listed in “Safety Information”...
Page 129
Hardware Installations and Upgrades 6. Install the replacement Intel® RAID Controller SRCSAS144E in the leftmost PCI slot (see letter “A” in the following figure), ensuring it is seated firmly in the slot. Replace the screw removed in the previous step (see letter “B”). Reconnect the BBU cable (see letter “C”).
Page 130
Unit The Intel® Intelligent AXXRIBBU1 Battery Backup Unit is installed in the right-hand PCI slot (when viewed from the rear) of the Intel® Storage Server SSR212MC2/ SSR212MC2R. Warning: Risk of explosion if battery pack is replaced by an incorrect type. The battery pack must...
Page 131
Hardware Installations and Upgrades 5. Disconnect the BBU cable to the Intel® RAID Controller SRCSAS144E (see letter “A” in the following figure). Release the screw in the retaining bracket at the back of the enclosure (see letter “B”). Ease the Intel® Intelligent AXXRIBBU1 Battery Backup Unit out of the PCI slot (see letter “C”).
Page 132
PCI slot (see letter “A” in the following figure). Support the Intel® Intelligent AXXRIBBU1 Battery Backup Unit while aligning the bracket and replacing the screw removed in step 5 (see letter “B”). Connect the BBU cable to the Intel® RAID Controller SRCSAS144E (see letter “C”).
Page 133
6. Loosen the two captive screws securing the brace assembly to the enclosure (see letter “A” in the following figure). Lift brace assembly out of enclosure (see letter “B”). Figure 130. Removing Brace Assembly Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 134
8. Turn the boot drive module over. Disconnect the disk drive cables (see letter “A” in the following figure) and the P4 power cable (see letter “B”) from the boot drive module backplane. Figure 132. Disconnecting Power Cable and Disk Drive Cables from Boot Drive Module Backplane Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 135
Hardware Installations and Upgrades 9. Remove the two screws securing the backplane to the boot drive module. Remove the backplane from the boot drive module. Figure 133. Removing Backplane from Boot Drive Module Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 136
(see letter “A” in the following figure). Secure disk drive to boot drive module with four screws (see letter “B”). Caution: When handling drives, ensure that they are placed (and stored) on a cushioned surface. Figure 134. Installing Lower Boot Drive Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 137
11. (Optional) Install second boot drive in upper slot with circuit side facing up and connectors oriented toward backplane (see letter “A” in the following figure). Secure disk drive to boot drive module with four screws (see letter “B”). Figure 135. Installing Upper Boot Drive Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 138
— Top boot drive to SATA 1 on server board • For Intel® Storage Server SSR212MC2R — Bottom boot drive to SAS 0 on server board — Top boot drive to SAS 1 on server board Figure 137. Connector Locations on Server Board Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 139
Figure 138. Re-installing Boot Drive Module 16. Re-install brace assembly in enclosure (see letter “A” in the following figure). Secure brace assembly to enclosure by tightening the two captive screws (see letter “B”). Figure 139. Re-installing Brace Assembly Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 140
The retaining bracket fits the space that was previously occupied by the expansion slot cover. 11. Secure the add-in board to the chassis with the screw that was previously removed. 12. Attach cables, if necessary. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 141
“Installing the Processor Air Duct” on page 14. Re-install the enclosure cover. For instructions, see “Installing the Enclosure Cover” on page 15. Reconnect all peripheral devices and the AC power cord(s). Power up the storage system. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 142
Hardware Installations and Upgrades Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 143
Computer Doesn’t Recognize the Subsystem 1. Check that the interface cables from the Intel® Storage Server SSR212MC2/ SSR212MC2R to the host computer are fitted correctly. 2. Check that the LEDs on all installed drive carrier modules are illuminated (amber).
Page 144
(cage related) 240VA limit (cage related) Blink green Current limit Amber Front Operator’s Panel The Front Operator’s Panel displays the aggregated status of all the modules. Front Operator’s Panel LED states are defined in Table Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 145
Disk drive status is monitored by a green LED and an amber LED mounted on the front of each Drive Carrier module. The conditions for each LED are defined in “Drive Carrier Module Faults” on page 133. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 146
Left No network connection is in place Solid green Active network connection is in place Blinking green Transmit / receive activity is occurring Right 10 Mbps connection (if left LED is on or blinking) Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 147
Slow beep. Fan light Fan broken or out of Replace lit fan. constant. tolerance No beep if muted. Slow beep. Drive Drive fault Replace drive light constant. No beep if muted. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 148
Operator’s Panel ID Buzzer Front Operator’s No issues Panel Fault LED Off Front Operator’s Muted. See Front Operator’s Panel Fault LED Panel LED settings Flashing or Constant above for interpretation of lights and remedy. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 149
On settings above Troubleshooting The following sections describe common problems, with possible solutions, which can occur with your Intel® Storage Server SSR212MC2/SSR212MC2R. For details on how to remove and replace a module see Section “Hardware Installations and Upgrades” on page...
Page 150
3. Fan LED is illuminated. 3. Reduce the ambient temperature. Thermal Control The Intel® Storage Server SSR212MC2/SSR212MC2R uses extensive thermal monitoring to ensure component temperatures are kept low and acoustic noise is minimized. Airflow is from front to rear of the enclosure.
Page 151
• If the subsystem is powered up and you remove any module, replace it immediately. If the subsystem is used with modules or module blanks missing for more than a few Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 152
Depending on how the enclosure system is set up, if a disk unit fails, it can normally be replaced without interrupting the use of the system. If an enclosure contains two PSUs, either PSU can maintain power to the system while the other is being replaced. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 153
Upgrading Component Firmware or the Server Board BIOS ® ® If replacing an Intel Server Board S5000PSL or Intel RAID Controller SRCSAS144E, refer to the support site at http://www.intel.com/support/motherboards/server/ssr212mc2 for downloading the appropriate firmware or BIOS. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 154
Upgrading Component Firmware Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 155
1 slot 2 D. RMM NIC connector E. PCI Express x4 slot 4 (ROMB F. PCI Express x8 slot 5 slot) G. PCI Express x8 slot 6 H. CMOS battery I. P12V4 connector Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 156
MM. SATA 3 or SAS 1 NN. SATA 4 or SAS 2 OO. SATA 5 or SAS 3 PP. USB port QQ. Front control panel RR. Serial B/emergency SS. Chassis intrusion header header management port header Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 157
2. Press <Ctrl> <G> at bootup when the following screen appears. 3. Once the Intel® RAID BIOS Console starts, a screen will appear displaying the adapter installed in the system. Select the Adapter No. 0 radio button and then click Start.
Page 158
Setting up RAID on the Intel® Storage Server SSR212MC2R Create a RAID Volume Note: Refer to the Intel® RAID Controller SRCSAS144E Software User Guide on the Resource CD for a description of applicable RAID levels and logical drive parameters. Note: Refer to the GUI Help files for more information on screen displays.
Page 159
Setting up RAID on the Intel® Storage Server SSR212MC2R 6. Select the configuration you wish to set up. (For this example, we selected “Custom Configuration”.) Click Next to continue. 7. Add physical drives to the array by holding the control key while clicking on ready drives.
Page 160
Setting up RAID on the Intel® Storage Server SSR212MC2R 8. If desired, define additional arrays. If finished, click Accept DG. Click Next to continue. 9. Select the RAID Level from the pull-down box. Enter in the size of the logical drive.
Page 161
Setting up RAID on the Intel® Storage Server SSR212MC2R 10. Click Accept. 11. Click Yes when asked to save the configuration. 12. Click Yes when asked to initialize the new logical drives. Depending on drive size and RAID level, initialization can take many hours to complete.
Page 162
Setting up RAID on the Intel® Storage Server SSR212MC2R Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 163
Therefore, software RAID on the 12 drives connected to the backplane is not supported. Software RAID is only supported on the boot drives. 1. Boot the system. 2. Press <Ctrl> <E> when prompted to start the Intel® Embedded Server RAID BIOS Configuration utility. Create a RAID Volume 3.
Page 164
Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 4. Select New Configuration and answer “yes” when prompted to proceed. The Array Selection Menu will be displayed. 5. Use the arrow keys to navigate to a drive. Press the space bar to add the selected drive to an array.
Page 165
Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 7. Repeat Steps 5 and 6 to create a second array if desired. Press <F10> when finished with creating all arrays. 8. Select an array by highlighting it and pressing the space bar. Press <F10> to configure the properties for the array.
Page 166
Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 9. The Logical Drives Configured screen will be displayed. This screen shows the: — Logical drive number — RAID level — Logical drive size — Number of stripes in the physical array —...
Page 167
Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 13. When you have finished defining the current logical drive, select Accept and press Enter. The Array Selection Menu screen will be displayed. 14. Repeat Steps 8 through 13 for all logical drives.
Page 168
Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 15. Select the array you just configured. Select “yes” when prompted to Save the configuration. Press ESC to return to the main menu. 16. Select Initialize. Caution: All data on the logical drive will be erased during an initialization.
Page 169
Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 Use the space bar to highlight the logical drive to initialize. 17. Press F10. Select Yes at the prompt and press Enter to begin the initialization. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 170
Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 18. A graph will appear showing progress of the initialization. 19. After the initialization is complete, press ESC to return to the previous menu. 20. Press ESC to return to the management menu.
Page 171
Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 22. Reboot the system by pressing <Ctrl> <Alt> <Del>. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 172
Setting Up RAID on the Boot Drives for the Intel® Storage Server SSR212MC2 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 173
RAID 0 usually denotes two or more drives. RAID 0 ABCDEF Available Capacity RAID Adapter N=# disks C = Disk Capacity Available Capacity = N*C Data Striping RAID 0 Figure 141. RAID 0 - Data Striping Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 174
RAID 5 ABCDEF Available Capacity RAID Adapter N=# disks C = Disk Capacity Available Capacity = Data Striping & (N*C)(N-1) /N Striped Parity RAID 5 Figure 143. RAID 5 - Data Striping with Striped Parity Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 175
Available Capacity RAID Adapter N=# disks C = Disk Capacity Available Capacity = (N*C) /2 Disk Mirror & Data Striping RAID 10 Figure 144. RAID 10 - Combination of RAID 1 and RAID 0 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 176
RAID Adapter N=# disks C = Disk Capacity Available Capacity = (N*C)(N-1) /N P1(B+D) P(F+H) P(J+L) RAID 5 & Data Striping RAID 50 Figure 145. RAID 50 - Combination of RAID 5 and RAID 0 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 177
Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). Before calling, fill out an “Intel®...
Page 178
Colombia ... Contact AT&T USA at 01 800 911 0010. Once connected, dial 800 843 4481 Costa Rica . Contact AT&T USA at 0 800 0 114 114. Once connected, dial 800 843 4481 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 179
Panama..Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481 Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 180
Getting Help Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 181
(or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.
Page 182
This product has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed in a compatible Intel® host system. For information on compatible host system(s) refer to Intel's Server Builder Web site or contact your local Intel representative.
Page 183
MED Declaration of Conformity (New Zealand) • BSMI Certification (Taiwan) • GOST R Certification / Certification (Russia) • Belarus Certification / Certification (Belarus) • RRL Certification (Korea) • IRAM Certification (Argentina) • CNCA Certification (China) Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 184
VCCI Marking (Class A) Japan BSMI Certification Taiwan Number & Class A Warning GOST R Marking Russia RRL MIC Mark Korea See the regulatory information document for additional information. China Compulsory China Certification Mark Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 185
Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment to an outlet on a circuit other than the one to which the receiver is connected. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 186
This product has been tested in accordance to, and complies with the Low Voltage Directive (73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to illustrate its compliance. VCCI (Japan) Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 187
Following is the RRL certification information for Korea. English translation of the notice above: 1. Type of Equipment (Model Name): On Certification and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4.
Page 188
Special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate. This notice is required by California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product/part includes a battery which contains perchlorate material. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 189
Restriction of Hazardous Substances (RoHS) Compliance Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration that materials banned in the RoHS Directive are either (1) below all applicable threshold limits or (2) an approved / pending RoHS exemption applies.
Page 190
End of Life / Product Recycling Product recycling and end-of-life take back systems and requirements vary from country to country. Contact the retailer or distributor of this product for information on product recycling and / or take back. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 191
"as is" unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
Page 192
Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
Page 193
Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
Page 194
Warranty Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 195
To do this: 1. Unlock and remove the padlock from the back of the system if a padlock has been installed. 2. Remove and save all screws from the covers. 3. Remove the cover(s). Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 196
• Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 197
Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 198
Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 199
Telekommunikationsleitungen mit dem Modem bestehen; • "mit einer geerdeten Wechselstromsteckdose ausgerüstet sein; • "über ausreichend Platz verfügen, um Zugang zu den Netzkabeln zu gewährleisten, da der Stromanschluß des Produkts hauptsächlich über die Kabel unterbrochen wird Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 200
Procédez comme suit: 1. Si un cadenas a été installé sur à l'arrière du système, déverrouillez-le et retirez-le. 2. Retirez toutes les vis des panneaux et mettez-les dans un endroit sûr. 3. Retirez les panneaux. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 201
• "Muni d'une prise murale correctement mise à la terre. • "Suffisamment spacieux pour vous permettre d'accéder aux câbles d'alimentation (ceux-ci étant le seul moyen de mettre le système hors tension). Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 202
Para ello: 1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos de las tapas.Extraiga las tapas. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 203
• "Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 204
1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 205
• "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 206
Installation/Assembly Safety Instructions Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 207
To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in ® this guide before installing or maintaining your Intel storage server. In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.
Page 208
AC power, 5V standby power is active whenever the system is plugged in. To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 209
Turn off all peripheral devices connected to this product. • Turn off the system by pressing the power button to off. • Disconnect the AC power by unplugging all AC power cords from the system or wall outlet. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 210
Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 211
Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 212
Safety Information Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, bevor Sie Ihr Intel®...
Page 213
• Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 214
Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
Page 215
Einbauen von Hot-Plug-Komponenten sorgfältig vor, um nicht mit heißen Komponenten in Berührung zu kommen. Vorsicht: Berühren Sie nicht die rotierenden Lüfterflügel, um Verletzungen zu vermeiden. Falls Ihr System mit eine Lüfterabdeckung besitzt, darf es nicht ohne diese Abdeckung betrieben werden. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 216
Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 217
Vorsicht: Beachten Sie zur Vermeidung von Strahlung und Verletzungen die folgenden Hinweise: • Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 218
Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant...
Page 219
• Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 220
Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
Page 221
Attention: Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre système est fourni avec une protection sur le ventilateur, ne mettez pas le système en route sans la protection en place. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 222
à la terre, exempte de charge statique, composants orientés vers le haut. Utilisez si possible un tapi de mousse conducteru, mais pas l’emballage de la carte. Veillez à ce que la carte ne glisse sur aucune surface. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 223
Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au fabricant en cas de problème. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 224
Safety Information Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , las carcasas de servidor de ® Intel (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento...
Page 225
Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 226
CA estén desenchufado antes de abrir la carcasa, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precauciónes al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
Page 227
Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 228
Utilice una almohadilla de espuma conductora si dispone de ella, pero nunca el envoltorio de la tarjeta. No deslice la tarjeta sobre ninguna superficie. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Page 229
Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. Intel® Storage Server SSR212MC2/SSR212MC2R User Guide...
Need help?
Do you have a question about the D90842-002 and is the answer not in the manual?