Download Print this page

Advertisement

Quick Links

HPE FlexFabric 5700 Switch Series
Installation Guide
Part number: 5998-5614s
Document version: 6W102-20160516

Advertisement

loading
Need help?

Need help?

Do you have a question about the FlexFabric 5700 48G 4XG 2QSFP+ and is the answer not in the manual?

Questions and answers

Summary of Contents for HPE FlexFabric 5700 48G 4XG 2QSFP+

  • Page 1 HPE FlexFabric 5700 Switch Series Installation Guide Part number: 5998-5614s Document version: 6W102-20160516...
  • Page 2 © Copyright 2016 Hewlett Packard Enterprise Development LP The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein.
  • Page 3 Contents Preparing for installation ················································································· 1   Safety recommendations ··································································································································· 2   Examining the installation site ···························································································································· 2   Temperature/humidity ································································································································ 3   Cleanliness ················································································································································· 3   EMI ····························································································································································· 4   Laser safety ················································································································································ 4   Installation tools ················································································································································· 4  ...
  • Page 4 Appendix A Chassis views and technical specifications ······························· 34   Chassis views ·················································································································································· 34   HPE 5700 48G 4XG 2QSFP+/HPE 5700 48G 4XG 2QSFP+ TAA ·························································· 34   HPE 5700 40XG 2QSFP+/HPE 5700 40XG 2QSFP+ TAA ····································································· 35   HPE 5700 32XGT 8XG 2QSFP+/HPE 5700 32XGT 8XG 2QSFP+ TAA ················································ 36  ...
  • Page 5 FlexFabric 5700 48G 4XG 2QSFP+ TAA-compliant products are assigned Regulatory Model Numbers (RMN). The Regulatory Model Numbers for these products are listed below. These regulatory numbers should not be confused with the marketing names HPE FlexFabric 5700, or product numbers JG894A and JG895A.
  • Page 6 FlexFabric 5700 40XG 2QSFP+ TAA-compliant products are assigned Regulatory Model Numbers (RMN). The Regulatory Model Numbers for these products are listed below. These regulatory numbers should not be confused with the marketing names HPE FlexFabric 5700, or product numbers JG896A and JG897A.
  • Page 7 Mount your switch in a rack and make sure: • Adequate clearance is reserved at the air inlet and outlet vents for ventilation. • The rack has a good ventilation system. • Identify the hot aisle and cold aisle at the installation site, and make sure ambient air flows into the switch from the cold aisle and exhausts to the hot aisle.
  • Page 8 ESD wrist strap. • Marker. Installation accessories Table 4 Installation accessories Product Description Quantity Applicable models code 1 U mounting bracket kit (including one pair of mounting brackets and eight M4 countersunk screws) 5066-0850 1 kit All HPE 5700 switches...
  • Page 9 HPE 5700 32XGT 8XG 2QSFP+ TAA 1 U long slide rail kit (including one pair of slide rails, one pair of • HPE 5700 48G 4XG 2QSFP+ guide rails, and four M4 • HPE 5700 48G 4XG 2QSFP+ countersunk screws)
  • Page 10 Product Description Quantity Applicable models code SFP/SFP+ dust plug 5185-8722 Optional All HPE 5700 switches QSFP+ dust plug 5187-9022 Optional All HPE 5700 switches...
  • Page 11 Installing the switch in a 19-inch rack Installation prerequisites To close the rack door easily, make sure the rack depth for the HPE 5700 32XGT 8XG 2QSFP+ and HPE 5700 32XGT 8XG 2QSFP+ TAA switches is a minimum of 1000 mm (39.37 in).
  • Page 12 Installation method distance distance • HPE 5700 48G 4XG 2QSFP+ Using mounting brackets and • HPE 5700 48G 4XG 2QSFP+ TAA 621 mm (24.45 874 mm long slide rails (supplied with • (34.41 in) HPE 5700 40XG 2QSFP+ the switch) •...
  • Page 13 (1) Chassis rail (2) Long slide rail Rack-mounting procedures at a glance Figure 4 Rack-mounting procedure NOTE: If a rack shelf is available, you can put the switch on the rack shelf, slide the switch to an appropriate location, and attach the switch to the rack with the mounting brackets. Attaching the mounting brackets, chassis rails, and grounding cable to the chassis The switch has one front mounting position (near the network ports) and one rear mounting position...
  • Page 14 (4) Auxiliary grounding point 1 (5) Front mounting position Figure 6 Mounting and grounding positions of the HPE 5700 48G 4XG 2QSFP+/HPE 5700 48G 4XG 2QSFP+ TAA/HPE 5700 40XG 2QSFP+/HPE 5700 40XG 2QSFP+ TAA switch (1) Auxiliary grounding point 2...
  • Page 15 NOTE: Secure the mounting brackets and chassis rails to both sides of the chassis in the same way. Connecting the grounding cable to the chassis CAUTION: The primary grounding point and auxiliary grounding point 1 are located on the left side panel. If you use one of these grounding points, you must connect the grounding cable to the grounding point before you mount the switch in the rack.
  • Page 16 Figure 8 Attaching the front mounting brackets/chassis rails to the chassis NOTE: As a best practice, use the primary grounding point or auxiliary grounding point 1 because the grounding cable and grounding screw that come with the switch are suitable only for these two grounding points.
  • Page 17 Mounting the switch in the rack This task requires two people. To mount the switch in the rack: Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded. Verify that the mounting brackets and chassis rails have been securely attached to the switch chassis.
  • Page 18 Figure 11 Mounting the switch in the rack (2) Grounding the switch WARNING! Correctly connecting the switch grounding cable is crucial to lightning protection and EMI protection. The power input end of the switch has a noise filter, whose central ground is directly connected to the chassis to form the chassis ground (commonly known as PGND).
  • Page 19 Attach the two-hole grounding lug at one end of the grounding cable to a grounding point on the switch chassis (see "Connecting the grounding cable to the chassis"). Remove the hex nut of a grounding post on the grounding strip. Attach the ring terminal at the other end of the grounding cable to the grounding strip through the grounding post, and fasten the ring terminal with the removed hex nut.
  • Page 20 • Do not operate the system outside of the temperature range 0°C to 45°C (32°F to 113°F) degrees. NOTE: • The fan trays in the HPE 5700 48G 4XG 2QSFP+, HPE 5700 48G 4XG 2QSFP+ TAA, HPE 5700 40XG 2QSFP+, and HPE 5700 40XG 2QSFP+ TAA switches must be the same type: LSWM1FANSC(JC682A) or LSWM1FANSCB(JC683A).
  • Page 21 Installing a fan tray CAUTION: To prevent damage to the fan tray or the connectors on the backplane, insert the fan tray gently. If you encounter a hard resistance while inserting the fan tray, pull out the fan tray and insert it again. Select appropriate fan trays as needed.
  • Page 22 WARNING! • The switch does not support intermixing of AC and DC power supplies. • HPE 5700 48G 4XG 2QSFP+ and HPE 5700 48G 4XG 2QSFP+ TAA switches do not support intermixing of 300W and 650W power supplies. • Provide a circuit breaker for each power supply and make sure the circuit breaker is off before installation.
  • Page 23 Figure 17 Installing a power supply Figure 18 Installing a power supply filler module Removing a power supply CAUTION: • If the switch has two power supplies, removing one power supply does not affect the operation of the switch. If the switch has only one power supply, removing the power supply powers off the switch.
  • Page 24 Figure 19 Removing the DC power cord (1) Press the tabs on the power cord connector (2) Pull the power cord connector out with your thumb and forefinger Figure 20 Removing the power supply (1) Pivot the latch to the right with your thumb (2) Pull the power supply out Connecting the power cord CAUTION:...
  • Page 25 Figure Connect the other end of the power cord to an AC power outlet. Figure 21 Connecting the AC power supply on the HPE 5700 40XG 2QSFP+ switch (1) Cable tie (2) Tighten the cable tie to secure the power cord to the handle of the power supply...
  • Page 26 Figure 22 Connecting the DC power supply on the HPE 5700 40XG 2QSFP+ switch Verifying the installation After you complete the installation, verify that: • There is enough space for heat dissipation around the switch, and the rack is stable.
  • Page 27 Accessing the switch for the first time Setting up the configuration environment The first time you access the switch you must use a console cable to connect a configuration terminal, for example, a PC, to the console port on the switch. Figure 23 Connecting the console port to a terminal Connecting the console cable A console cable is an 8-core shielded cable, with a crimped RJ-45 connector at one end for...
  • Page 28 After the startup completes, you can access the CLI to configure the switch. For more information about the configuration commands and CLI, see HPE FlexFabric 5700 Switch Series Configuration Guide and HPE FlexFabric 5700 Switch Series Command References.
  • Page 29 Setting up an IRF fabric You can use HPE IRF technology to connect and virtualize HPE FlexFabric 5700 switches into a large virtual switch called an "IRF fabric" for flattened network topology, and high availability, scalability, and manageability. IRF fabric setup flowchart...
  • Page 30 Distribute the IRF member switches in different racks to implement the top-of-rack (ToR) access solution for a data center. As your business grows, you can plug HPE FlexFabric 5700 switches into the IRF fabric to increase the switching capacity without any topology change or replacement.
  • Page 31 IRF-port 1 on one switch to the physical ports of IRF-port 2 on the other switch. The HPE 5700 48G 4XG 2QSFP+, HPE 5700 48G 4XG 2QSFP+ TAA, HPE 5700 40XG 2QSFP+, and HPE 5700 40XG 2QSFP+ TAA switches can provide 10-GE and 40-GE IRF connections through SFP+ ports and QSFP+ ports, respectively.
  • Page 32 Identify the ports to be used for IRF connections on the member switches according to your topology and connection scheme. All ports on the front panel of the HPE FlexFabric 5700 switch can be used for IRF connections. Follow these guidelines when you identify 1/10-GE Ethernet ports and SFP+ ports to be used for IRF connections: •...
  • Page 33 Figure 29 IRF fabric topology Connecting the IRF member switches in a ToR solution You can install IRF member switches in different racks side by side to deploy a top of rack (ToR) solution. Figure 30 shows an example for connecting four top of rack IRF member switches by using SFP+/QSFP+ DAC cables, and SFP+/QSFP+ transceiver modules, and optical fibers.
  • Page 34 • To bind the ports on an interface card to an IRF port, you must install the interface card first. For how to install an interface card, see HPE FlexFabric 5700 Switch Series Interface Cards User Guide. •...
  • Page 35 To avoid IP address collision and network problems, configure at least one multi-active detection (MAD) mechanism to detect the presence of multiple identical IRF fabrics and handle collisions. For more information about MAD detection, see HPE FlexFabric 5700 Switch Series IRF Configuration Guide.
  • Page 36 • HPE A58x0AF 650W AC (JC680A) & 650W DC (JC681A) Power Supplies User Guide. • HPE FlexFabric Switch 650W 48V Hot Plug NEBS Compliant DC Power Supply (JH336A) User Guide. Symptom The LEDs on the power supply are not steady green (active) or flashing green (standby).
  • Page 37 No terminal display Symptom The configuration terminal has no display when the switch is powered on. Solution To resolve the problem: Verify that the power system is operating correctly. Verify that the switch is operating correctly. Verify that the console cable has been connected correctly. Verify that the following settings are configured for the terminal: Baud rate—9600.
  • Page 38 (9) ACT LED for the management Ethernet port (10) USB port The HPE 5700 48G 4XG 2QSFP+ and HPE 5700 48G 4XG 2QSFP+ TAA switches come with the power supply slots empty and the filler modules for the slots as accessories. You can install one or 32, two 650 W AC power supplies are two power supplies for the switch as needed.
  • Page 39 (9) ACT LED for the management Ethernet port (10) USB port The HPE 5700 40XG 2QSFP+ and HPE 5700 40XG 2QSFP+ TAA switches come with the power supply slots empty and the filler modules for the slots as accessories. You can install one or two power supplies for the switch as needed.
  • Page 40 The HPE 5700 40XG 2QSFP+ and HPE 5700 40XG 2QSFP+ TAA switches also come with the fan tray slots empty. You must install two fan trays of the same model for the switch. In Figure 35, two LSWM1FANSC fan trays are installed. For more information about installing and removing a fan tray, "Installing/removing a fan...
  • Page 41 "Installing/removing a power supply." The HPE 5700 32XGT 8XG 2QSFP+ and HPE 5700 32XGT 8XG 2QSFP+ TAA switches also come with the fan tray slots empty. You must install two fan trays of the same model for the switch. Figure 38, two LSWM1HFANSC fan trays are installed.
  • Page 42 HPE 5700 32XGT 8XG HPE 5700 40XG HPE 5700 48G 4XG 2QSFP+/HPE 5700 Item 2QSFP+/HPE 5700 2QSFP+/HPE 5700 32XGT 8XG 2QSFP+ 40XG 2QSFP+ TAA 48G 4XG 2QSFP+ TAA • Single AC input: 83 • • Single AC input: 135 Single AC input: 98 W •...
  • Page 43 NOTE: • The switches do not support intermixing of AC and DC power supplies. • HPE 5700 48G 4XG 2QSFP+ and HPE 5700 48G 4XG 2QSFP+ TAA switches do not support intermixing of 300W and 650W power supplies. • When a switch has two power supplies for redundancy, you can replace a power supply without powering off the switch.
  • Page 44 Fan trays Item Specifications LSWM1FANSC (for the HPE 5700 48G 4XG 2QSFP+, HPE 5700 48G 4XG 2QSFP+ TAA, HPE 5700 40XG 2QSFP+, and HPE 5700 40XG 2QSFP+ TAA switches) Fans Two 40 × 40 × 28 mm (1.57 × 1.57 × 1.1 in) fans Fan speed 18500 R.P.M...
  • Page 45 HPE LSWM1HFANSC & LSWM1HFANSCB Installation Manual NOTE: • The fan trays in the HPE 5700 48G 4XG 2QSFP+, HPE 5700 48G 4XG 2QSFP+ TAA, HPE 5700 40XG 2QSFP+, and HPE 5700 40XG 2QSFP+ TAA switches must be the same type: LSWM1FANSC or LSWM1FANSCB.
  • Page 46 Appendix C Ports and LEDs Ports Console port The switch has one console port. Table 9 Console port specifications Item Specification Connector type RJ-45 Compliant standard EIA/TIA-232 Transmission baud rate 9600 bps (default) to 115200 bps • Provides connection to an ASCII terminal. •...
  • Page 47 Product Module wavelengt Connect diameter bandwidt transmissio Code description (µm) n distance (nm) (MHz × HPE X120 1G Category-5 100 m JD089B SFP RJ45 T RJ-45 twisted pair (328.08 ft) transceiver 550 m (1804.46 ft) Multi-mode, 50/125 500 m HPE X120 1G (1640.42 ft)
  • Page 48 Enterprise sales representative or Hewlett Packard Enterprise Support. For the SFP transceiver module specifications, see HPE Comware-Based Devices Transceiver Modules User Guide. The SFP+ DAC cables available for the HPE FlexFabric 5700 switches are 10 Gbps SFP+ DAC Cables, as shown in Figure...
  • Page 49 Table 15 40G QSFP+ DAC cables available for the switch Product Cable description Cable length code JG326A HPE X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable 1 m (3.28 ft) JG327A HPE X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable 3 m (9.84 ft) JG328A HPE X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable 5 m (16.40 ft)
  • Page 50 Table 16 40G QSFP+ to 4x10G SFP+ DAC cables available for the switch Product Cable description Cable length code HPE X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter JG329A 1 m (3.28 ft) Cable HPE X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter JG330A 3 m (9.84 ft)
  • Page 51 For QSFP+ transceiver module and cable specifications, see HPE Comware-Based Devices Transceiver Modules User Guide. 10/100/1000Base-T autosensing Ethernet port The HPE 5700 48G 4XG 2QSFP+ and HPE 5700 48G 4XG 2QSFP+ TAA switches have 10/100/1000Base-T autosensing Ethernet ports. Table 17 10/100/1000Base-T autosensing Ethernet port specifications...
  • Page 52 • Use category-6A or above cables and connectors. • Do not bundle cables in their first 20 m (65.62 ft). • Separate power cords and twisted pair cables at and around the distribution frame. • For ports adjacent to one another on the device, the peer ports on the distribution frame is preferably not adjacent, for example: If the device connects to one distribution frame, connect port 1 on the device to port 1 on the distribution frame, port 2 on the device to port 3 on the distribution frame, and port 3 on the...
  • Page 53 Table 21 QSFP+ port LED description LED status Description A transceiver module or cable has been correctly installed. A link is present, and Steady green the port is operating at 40 Gbps. Flashing green The port is sending or receiving data at 40 Gbps. A transceiver module or cable has been correctly installed.
  • Page 54 LED mark Status Description The management Ethernet port is not receiving or sending data. Flashing yellow The management Ethernet port is sending or receiving data.
  • Page 55 The fan trays in the HPE 5700 48G 4XG 2QSFP+, HPE 5700 48G 4XG 2QSFP+ TAA, HPE 5700 40XG 2QSFP+, and HPE 5700 40XG 2QSFP+ TAA switches must be the same type: LSWM1FANSC or LSWM1FANSCB.
  • Page 56 Figure 45 Airflow through the HPE 5700 32XGT 8XG 2QSFP+ chassis (with LSWM1HFANSCB fan trays) (1) Power supply air vents (2) Fan tray air vents (3) Network port-side air vents IMPORTANT: The chassis and the power supplies use separate air aisles. Make sure both aisles are not blocked.
  • Page 57 Document conventions and icons Conventions This section describes the conventions used in the documentation. Port numbering in examples The port numbers in this document are for illustration only and might be unavailable on your device. Command conventions Convention Description Bold text represents commands and keywords that you enter literally as shown. Boldface Italic text represents arguments that you replace with actual values.
  • Page 58 Convention Description An alert that provides helpful information. TIP: Network topology icons Convention Description Represents a generic network device, such as a router, switch, or firewall. Represents a routing-capable device, such as a router or Layer 3 switch. Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that supports Layer 2 forwarding and other Layer 2 features.
  • Page 59 Support and other resources Accessing Hewlett Packard Enterprise Support • For live assistance, go to the Contact Hewlett Packard Enterprise Worldwide website: www.hpe.com/assistance • To access documentation and support services, go to the Hewlett Packard Enterprise Support Center website: www.hpe.com/support/hpesc Information to collect •...
  • Page 60 For more information and device support details, go to the following website: www.hpe.com/info/insightremotesupport/docs Documentation feedback Hewlett Packard Enterprise is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (docsfeedback@hpe.com). When submitting your feedback, include the document title,...
  • Page 61 part number, edition, and publication date located on the front cover of the document. For online help content, include the product name, product version, help edition, and publication date located on the legal notices page.
  • Page 62 Index connecting grounding cable to switch chassis, Numerics rail, 1/10GBase-T autosensing Ethernet views, port, cleanliness port LED, installation site, 10/100/1000 Base-T autosensing Ethernet compatibility matrixes, port, configuring port LED, accessing IRF fabric to verify the configuration, 19-inch rack IRF basic settings, switch installation, switch, troubleshooting configuration terminal...
  • Page 63 grounding switch with grounding strip, 10/100/1000 Base-T autosensing Ethernet port LED technical specifications, grounding the switch, 10/100/1000 Base-T autosensing Ethernet port power supply installation, 18, 18, technical specifications, power supply removal, 18, 19, connecting AC power supply, powering on switch, connecting DC power supply, troubleshooting power supply failure, console port technical specifications,...
  • Page 64 prerequisite for switch installation on 19-inch IRF fabric, rack, member rack chassis rails, configuring IRF member switch basic settings, rack mounting bracket, connecting IRF physical ports, rack mounting grounding cable, identifying IRF member switch physical ports, safety recommendations, IRF member ID, site cleanliness, site humidity, troubleshooting fan failure,...
  • Page 65 powering on switch, installing mounting bracket, preparing for installation, mounting procedure, prerequisite mounting the switch, switch installation on 19-inch rack, prerequisite for switch installation on 19-inch rack, preventing rack mounting rail kit, EMI prevention, switch installation on 19-inch rack, procedure verifying switch installation (19-inch rack), configuring IRF basic settings, removing...
  • Page 66 first time access, temperature grounding, installation site requirements, grounding through AC power supply PE terminal wire, troubleshooting garbled terminal display, grounding with grounding strip, troubleshooting no terminal display, identifying IRF master switch, tools needed for installation, identifying IRF member switch physical topology ports, planning IRF cabling scheme, 28,...