Baoding Longer Precision Pump T100&JY15-12 Series Operating Manual

Variable speed peristaltic pump

Advertisement

Quick Links

T100&JY15-12 Series Variable Speed
Peristaltic Pump Operating Manual
2013-10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T100&JY15-12 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Baoding Longer Precision Pump T100&JY15-12 Series

  • Page 1 T100&JY15-12 Series Variable Speed Peristaltic Pump Operating Manual 2013-10...
  • Page 2: Table Of Contents

    Baoding Longer Precision Pump Co., Ltd. Contents 1 General Information ........................1 1.1 Precaution ........................1 1.2 Warranty and Service ....................1 1.2.1 Warranty Service ....................1 1.2.2 Maintenance Service ..................2 1.2.3 Service Commitment ..................2 1.2.4 Dispute Settlement .....................2 1.3 Repair Notes.........................2 1.4 Contacts Information.....................2 2 Pump Introduction........................3...
  • Page 3: General Information

    Baoding Longer Precision Pump Co., Ltd. 1 General Information 1.1 Precaution If tubing leaks or bursts, fluid may spray from the tubing and pump head. Take  reasonable practicable measures to ensure the operators’ safety.  Make sure fluid in the tubing has been drained out, no pressure in the pipeline and disconnect pump from mains power, while removing or replacing the tubing.
  • Page 5: Pump Introduction

    Baoding Longer Precision Pump Co., Ltd. 2 Pump Introduction 2.1 Main Features T100&JY15-12 series variable speed peristaltic pumps, including T100 pump drive and JY15-12 pump head, are mainly designed for ODM applications. The speed can be controlled by BCD dial switch or external control signal, with100 rpm as max. This pump offers flow rate from 0.7 to 170mL/min and can be mounted to customer equipment through soleplate.
  • Page 6: Main Function

    Baoding Longer Precision Pump Co., Ltd. 2.2 Main Function 2.2.1 T100-S9/S10/S11/S12&JY15-12 Main Function 1) Fitted with JY15-12 pump head. 2) Pump speed can be controlled through internal control mode or external control mode. The internal control mode uses BCD dial switch. The external control mode uses current, voltage or pulse signal.
  • Page 7: T100-S101&Jy15-12 Specification

    Baoding Longer Precision Pump Co., Ltd. 2.3.2 T100-S101&JY15-12 Specification Speed: 0-100rpm Speed resolution: 0.1rpm ® Tubing options: 25# 17# silicone tubing or PharMed tubing. Baud rate (bit rate): 1200 or 9600 baud (1200 or 9600 bps). Refer to table 5 for data transmission speed setting.
  • Page 8: Operating Instruction

    Baoding Longer Precision Pump Co., Ltd. Figure 1 3 Operating Instruction 3.1 Pump Head Mounting JY15-12 pump head rotor drive shaft is the motor output shaft. The rotor needs re-aligning when mount the pump head on the pump drive. We don’t recommend that you change JY15-12 pump head by yourself.
  • Page 9: Pump Mounting

    Baoding Longer Precision Pump Co., Ltd. 3.3 Pump Mounting T100&JY15-12 series variable speed peristaltic pump can be mounted on customer equipment through soleplate. Refer to Figure 1 “Mounting Hole” for the mounting position. 3.4 Hardware Setting 3.4.1 Power Supply The power supply requirement is DC 11.4V-25.2V and power ≥12W. For the power supply terminal position, please refer to Figure 2 and Table 2 for T100-S9/S10/S11/S12&JY15-12,...
  • Page 10 Baoding Longer Precision Pump Co., Ltd. Figure 2 shows BCD dial switch and wiring terminal on control circuit board. Refer to Table 2 for wiring terminal definition. BCD Dial Switch Wiring Terminal J1 1 2 3 4 5 6 7 8 9 Figure2 Table2:Wiring Terminal Instruction...
  • Page 11: T100-S101&Jy15-12 Communication Address Setting, Wiring Terminal And Communication Wire Connection Instruction

    Baoding Longer Precision Pump Co., Ltd. 3.4.3 T100-S101&JY15-12 Communication Address Setting, Wiring Terminal and Communication Wire Connection Instruction T100-S101&JY15-12 receives RS485 communication signal to control start/stop, speed, direction and prime function. It also has the function of power-off memory. The data transmission speed and communication address are set through DIP switch.
  • Page 12 Baoding Longer Precision Pump Co., Ltd. 485-A User’s J1-1 485-B Communication Wiring Terminal J1 J1-2 Interface J1-3 2) User’s communication interface is RS232, please refer to below wiring diagram: 485-A User’s J1-1 RS232/RS485 Wiring Terminal J1 Communication 485-B J1-2 Converter...
  • Page 13: Operation

    Baoding Longer Precision Pump Co., Ltd. 3.5 Operation 3.5.1 T100-S9/S10/S11/S12&JY15-12 Operating Procedures 1) Ensure the power supply is DC 11.4V-25.2V and power≥12W. 2) Connect the power supply and necessary control signal wire according to Figure 2 and Table 2. Control the pump start/stop with switch signal connected to J1-5 and J1-7 terminals.
  • Page 14: T100-S101&Jy15-12 Operating Procedures

    Baoding Longer Precision Pump Co., Ltd. the pump speed. Pump will be at 0 rpm but still in running state, when BCD is set at “0” position. Pump will stop when close start/stop switch. We recommend external control mode where a high number of speed changes is required.
  • Page 15: Appendix A:t100-S101&Jy15-12 Communication Protocol

    Baoding Longer Precision Pump Co., Ltd. APPENDIX A:T100-S101&JY15-12 Communication Protocol 1. Frame format: 1start + 8data + 1even parity + 1stop, 1200bps or 9600bps 2. Message format: flag+ addr + len + pdu + fcs. flag: E9H, as message head. When sending the message, the data E8H after message head will be replaced with E8H 00H, and E9H after message head will be replaced with E8H 01H.
  • Page 16 Baoding Longer Precision Pump Co., Ltd. Note: When read the running state, the addr in the message only can be pump address (1-30). Read pump address PC calls: Pump responds:  RID: 3 bytes, using ASCII code, to indicate that this call is used to read pump address.

Table of Contents