Schematic Diagram - Haier FCD-8 User Manual

Mini sea-ox household electric water heater

Advertisement

Dimension Figure
Front view
a1
b1
B
A
Net
Model Volum e
a1
weight
FCD-8
5kg
8L
325mm
Remarks:the permitted error limit of above parameters is

Schematic Diagram

L:Brown wire
N:Blue wire
MT:High temperature limiter
EH:Heating element
E:Yellow/green wire
N
BT:
Thermostat
HL:Heating indicator
PDF 文件使用 "pdfFactory Pro" 试用版本创建 ÿ
Side view
Cutaway view
E
D
C
A
B
c1
A Hot water outlet
B Cold water inlet
b 1
c1
d1
C Mg anode rod
D Heating element
414 mm
100mm
25 5mm
E Enamel tank
F Wall-mounting bracket
±
10%.
MT
BT
L
HL
E
3
www.fineprint.cn
(Fig ure 1)
Figure 1
Be sure to have it installed by the appointed staff. It adopts wall-mounting installation.
First decide the installation location according to the usage requirement. Make two
holes in the wall with depth 70mm and
installation diagram.
Fasten the wall-mounting plate on the wall tightly with two expansion bolts as per
indicated in Figure 2. Check and confirm that the bolts are not loose.
Hang the water heater vertically onto the wall by the wall-mounting plate. Confirm it
is firmly mounted. Please reserve certain space for the future maintenance during
F
installation.
d1
When the power is switched on, and the water heater starts operating, there may
be some water discharged from the pressure relief hole of safety valve. It is due to
the water expansion under heating, and is normal phenomenon. The pressure
relief hole shall communicate with the air directly. Do not block it.
heater will be installed in the bathroom without sewer, we suggest you add drain
hose.
Figure 3). According to the need, you could truncate or elongate the hose in your
favor. Connect the other end of drain hose to the sewer to avoid polluting the
room by splashing. The drain hose connecting to the safety valve shall be kept
downward sloping in installation and in a frost-free environment.
Be sure to check and confirm that the tank is filled with water, there is no leakage
at each joint and the power supply complies with the stipulation before switching
on the power.
(Figure 4) for reference in installation only
EH
E
Installation
φ
9mm by churn drill as per the indication of
(Figure 2)
6 5 m m
Wall-mounting
Expansion bolt
plate
Fasten the drain hose to the drain thread of safety valve by twisting (see to
Hot water outlet
Cold water inlet
4
(Figure 3)
Connect to drain hose
If the water
Safety valve