Insulation Blankets - Kenmore 33176 - Power Miser 12 Owner's Manual

For potable water heating only not suitable for space heating not for use in mobile homes
Table of Contents

Advertisement

This water
heater
must
not be installed
directly
on carpeting.
Carpeting
must
be protected
by metal
or wood
panel
beneath
the appliance
extending
beyond
the full width
and depth
of the
appliance
by at least 3 inches
(76.2 mm) in any direction,
or if
the appliance
is installed
in an alcove
or closet,
the entire floor
must be covered
by the panel.
Failure
to heed this warning
may
result
in a fire hazard.
Fire or Explosion
Hazard
using or servicing water heater.
• Improper use may result in fire or
explosion.
, Maintain
required
clearances
to
combustibles.
Minimum
clearances
between
the
water
heater
and
combustible
construction
are 0 inch
at the sides
and
rear,
4 inches
(102
mm) at the front,
and 6 inches
(153
mm) from
the vent
pipe,
see
Figure
8.
Clearance
from
the top of the
jacket
is 12 inches
(305
mm)
on most
models.
Note that a
lesser
dimension
may
be allowed
on some
models,
refer
to
the label
attached
adjacent
to the gas
control
valve
on the
water
heater.
TOP VIEW
OF CLOSET
WITHOUT DOOR
0" MIN.
TOP VIEW
OF CLOSET
WITH DOOR
_{
1040" MIN.
" NIIN,
4 ram)
0" MIN.
0" MIN.
FIGURE
8.
Breathing
Hazard - Carbon
Monoxide
Gas
1,:_.
.:'_'.°:.,
" Install water heater in accordance
with
_;.:, :
:_,::_.
the instruction manual and NFPA54.
:?:"i_i°:_':._
"_!:_':if':°
° To
avoid
injury, combustion
and
_: _!._!
_
outdoors.Ventilati°n
air must
be taken
from
. Do not place chemical vapor emitting
products near water heater.
Breathing
carbon
monoxide
can cause
brain damage
or
death.
Always
read and understand
instruction
manual.
A gas water
heater
cannot
operate
properly
without
the correct
amount
of air for combustion,
see Figure
9. Do not install
in a
confined
area such as a closet,
unless
you provide
air as shown
in the Combustion
Air and Ventilation
forAppliances
Located
in
Confined
Spaces
section.
Never obstruct
the flow of ventilation
air.
If you
have
any doubts
or questions
at all, call your
gas
supplier.
Failure
to provide
the proper
amount
of combustion
air can
result
in a fire or explosion
and cause
death,
serious
bodily
injury, or property
damage.
__12" MAX. (30 cm)
VENTiLATiON
AiR
OPENING O
FRONT
VIEW
OF DOOR
AIR DUCT
FIGURE 9.
If this water
heater
will be used in beauty
shops,
barber
shops,
cleaning
establishments,
or self-service
laundries
with
dry
cleaning
equipment,
it is imperative
that the water heater or water
heaters
be installed
so that combustion
and ventilation
air be
taken
from outside
these
areas.
Propellants
of aerosol
sprays
and volatile
compounds,
(cleaners,
chlorine
based
chemicals,
refrigerants,
etc.) in addition
to being
highly
flammable
in many
cases,
will also change
to corrosive
hydrochloric
acid when exposed
to the combustion
products
of
the water heater.
The results
can be hazardous,
and also cause
product
failure.
Insulation
Blankets
Insulation
blankets
available
to the general
public
for external
use on gas
water
heaters
are not necessary
with
Kenmore
products.
The purpose
of an insulation
blanket
is to reduce
the
standby
heat loss encountered
with storage
tank heaters.
Your
Kenmore
water
heater
meets or exceeds
the EPACT
standards
with respect
to insulation
and standby
loss requirements,
making
an insulation
blanket
unnecessary.
10
Breathing
Hazard - Carbon
Monoxide
Gas
o Do not obstruct water heater air intake
with insulating blanket.
Gas and carbon monoxide
detectors
are available.
o Install water heater in accordance with
the instruction manual.
Breathing
carbon
monoxide
can cause brain damage
or
death.
Always
read and understand
instruction
manual.
,_
WARNING
Should
you choose
to apply an insulation
blanket
to this heater,
you
should
follow
these
instructions
(See
Figure
1 for
identification
of components
mentioned
below).
Failure
to follow
these
instructions
can
restrict
the air flow
required
for proper
combustion,
potentially
resulting
in fire, asphyxiation,
serious
personal
injury or death.
Do not apply insulation
to the top of the water
heater, as this
will interfere
with safe operation
of the draft hood.
Do not cover
the outer
door, thermostat
or temperature
&
pressure
relief valve.
Do not allow insulation
to come
within
2" (50.8
mm) of the
floor to prevent
blockage
of combustion
air flow to the burner.