Insulation Blankets - Kenmore 153.559400 Use & Care Manual

Table of Contents

Advertisement

Fire or Explosion
Hazard
Read instruction manual before installing,
using or servicing water heater.
• Improper use may result in fire or
explosion.
• Maintain
required
clearances
to
corn bustibles.
Minimum clearances between the water heater and combustible
surfaces are 0 inch at the sides and rear, 4 inches (102 mm)
at the front, and 6 inches (153 mm) from the vent pipe. See
Figure 8. Clearance from the top of the jacket is 8 inches (203
mm) on most models.
Note that a lesser dimension
may be
allowed on some models.
Refer to the label attached adjacent
to the gas control valve on the water heater.
TOP VIEW
OF CLOSET
WITHOUT DOOR
0" MIN.
TOP VIEW
OF CLOSET
WITH DOOR
(104 turn)
0" MIN.
FIGURE
8.
Breathing
Hazard - Carbon Monoxide
Gas
12" MAX. (30 cm)
1
VE_ON
I
FRONT
VIEW
t
OF DOOR
3" MIN,
76.2 mm
AIR DUCT
FIGURE
9.
If this water heater wilt be used in beauty shops, barber shops,
cleaning
establishments,
or self-service
laundries
with dry
cleaning equipment,
it is imperative that the water heater or
water heaters be installed so that combustion and ventilation
air be taken directly from outdoors (direct vent).
Propellants of aerosol sprays and volatile compounds, (cleaners,
chlorine based chemicals, refrigerants, etc.) in addition to being
highly flammable in many cases, wilt also change to corrosive
hydrochloric acid when exposed to the combustion products of
the water heater. The results can be hazardous, and also cause
product failure.
Insulation
Blankets
Insulation blankets available to the general public for external
use on gas water heaters are not necessary
with Kenmore
products. The purpose of an insulation blanket is to reduce the
standby heat toss encountered with storage tank heaters. Your
Kenmore water heater meets or exceeds the National Appliance
Energy Conservation
Act standards with respect to insulation
and standby loss requirements,
making an insulation blanket
unnecessary.
Install water heater in accordance
with the instruction manual and
NFPA 54.
To avoid injury, combustion and
ventilation air must be taken from
outdoors.
• Do
not
place
chemical
vapor
emitting
products
near
water
heater.
Breathing carbon monoxide can cause brain damage or
death. Always read and understand instruction manual.
A gas water heater cannot operate properly without the correct
amount of air for combustion.
See Figure 9. Do not install in a
confined area such as a closet, unless you provide air as shown
in the Locating The New Water Heater section.
Never obstruct
the flow of ventilation air. If you have any doubts or questions at
all, call your gas supplier. Failure to provide the proper amount of
combustion air can result in a fire or explosion and cause death,
serious bodily injury, or property damage.
11
Breathing
Hazard - Carbon
Monoxide
Gas
• Do not obstruct water heater air
intake with insulating blanket.
• Gas and carbon monoxide detectors
are available.
• Install water heater in accordance
with the instruction manual.
Breathing carbon monoxide can cause brain damage or
death. Always read and understand instruction manual.
,_
WARNING
Should you choose
to apply an insulation
blanket
to this
heater, you should follow these instructions
(See Figure 1 for
identification of components mentioned below). Failure to follow
these instructions can restrict the air flow required for proper
combustion,
potentially resulting in fire, asphyxiation,
serious
personal injury or death.
Do not apply insulation to the top of the water heater, as this
wilt interfere with safe operation of the draft hood.
Do not cover the outer door, thermostat or temperature
&
pressure relief valve.
Do not allow insulation to come within 2" (50.8 mm) of the
floor to prevent blockage of combustion air flow to the burner.
Do not cover the instruction manual. Keep it on the side of
the water heater or nearby for future reference.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.559500

Table of Contents