Filling The Water Heater; Venting - Kenmore 33176 - Power Miser 12 Owner's Manual

For potable water heating only not suitable for space heating not for use in mobile homes
Table of Contents

Advertisement

Water
temperature
over
125°F
(52°0)
can cause severe burns
instantly resulting in severe injury
or death.
Children,
the
elderly,
and
the
physically
or mentally
disabled
are at highest riskforscald
injury.
Feel
water
before
bathing
or
showering.
Temperature
limiting valves are
available.
Read instruction
manual for safe
temperature setting.
The
temperature-pressure
relief
valve
must
be manually
operated
at least
once
a year.
Caution
should
be taken
to
ensure
that (1) no one is in front
of or around
the outlet
of
the temperature-pressure
relief
valve
discharge
line,
and
(2) the water
manually
discharged
will not cause
any
bodily
injury
or
property
damage
because
the
water
may
be
extremely
hot.
If after
manually
operating
the valve,
it fails
to completely
reset
and continues
to release
water,
immediately
close
the
cold
water
inlet
to the
water
heater,
follow
the
draining
instructions,
and replace
the temperature-pressure
relief valve
with a new one.
Filling
the Water Heater
Property
Damage
Hazard
• Avoid water heater
damage,
- Fill tank with water
before operating.
Venting
Breathing
Hazard - Carbon
Monoxide
Gas
• Vent
dampers
must
be certified
in
accordance
with ANSI
Z2t.66/CSA
6.14.
• Vent
damper
must
permit
proper
drafting of water heater.
• Install properlysizedventing.
*Do
not
install
without
venting
outdoors.
• Do not install without drafthood.
• if
common
vented
install
in
accordance
with NFPA54.
• Be
alert
for
obstructed
or
deteriorated
vent
system
to avoid
serious
injury or death.
Breathing
carbon
monoxide
can cause
brain damage
or
death. Always
read and understand
instruction
manual.
VENT
DAMPERS
- Any vent
damper,
whether
it is operated
thermally
or otherwise
must be removed
if its use inhibits
proper
drafting
of the water
heater.
Thermally
Operated
Vent
Dampers:
This
gas-fired
water
heater
has a thermal
efficiency
at or above
80% which
may
produce
a relatively
low
flue
gas
temperature.
Such
temperatures
may not be high enough
to properly
open thermally
operated
vent dampers.
This would
cause
spillage
of the flue
gases
and may cause carbon
monoxide
poisoning.
Vent dampers
must bear evidence
of certification
as complying
with
the current
edition
of the American
National
Standard
ANSI
Z21.66/CGA
6.14,
cover
electrically
and mechanically
actuated
vent dampers).
Before
installation
of any vent damper,
consult
your local Sears Service
Center
or the local gas supplier
for further
information.
Never use this water
heater
unless
it is completely
full of water.
To prevent
damage
to the tank, the tank must be filled with water.
Water
must flow from the hot water faucet
before
turning
"ON"
gas to the water
heater.
To fill the water
heater with water:
Close
the water
heater drain
valve
by turning
the handle
to
the right (clockwise).
The drain
valve
is on the lower front of
the water
heater.
Open the cold water
supply
valve to the water
heater.
NOTE:
The
cold
water
supply
valve
must
be left open
when
the water
heater
is in use.
To insure
complete
filling
of the tank,
allow
air to exit
by
opening
the nearest
hot water
faucet.
Allow
water
to run
until a constant
flow
is obtained.
This will let air out of the
water
heater
and the piping.
Check
all water
piping and connections
for leaks.
Repair
as
needed.
To insure proper venting
of this gas-fired
water heater, the correct
vent pipe diameter
must be utilized.
Any additions
or deletions
of other gas appliances
on a common
vent with this water
heater
may adversely
affect the operation
of the water
heater.
Consult
your
gas supplier
if any such changes
are planned.
For proper
venting
in certain
installations,
a larger diameter
vent
pipe may be necessary.
Consult your local Sears Service
Center
or gas supplier
to aid you in determining
the proper
venting
for
your
water
heater
from the vent tables
in the current
edition
of
the National
Fuel Gas Code ANSI Z223.1/NFPA
54.
Periodically
check
the venting
system
for signs of obstruction
or
deterioration
and replace
if needed.
The combustion
and ventilation
air flow must not be obstructed.
15
The water heater with draft hood installed
must be connected
to
a chimney
or listed vent
pipe system,
which
terminates
to the
outdoors.
Never operate
the water
heater
unless
it is vented
to
the outdoors
and has
adequate
air supply
to avoid
risks
of
improper
operation,
explosion
or asphyxiation.