Water Piping - Kenmore 3314 - Power Miser 12 Owner's Manual

For potable water heating only, not suitable for space heating, not for use in mobile homes
Table of Contents

Advertisement

VENTULAT+ON
LOUVERS
OUTLET
FIGURE 12+
When
communicating
with
the outdoors
through
horizontal
ducts,
each
opening
shall
have
a minimum
free area
of 1
square
inch per 2,000
BTU
per hour (11 cm_/kW)
of total
input
rating
of all
equipment
in the
enclosure.
See
Figure
13.
When
ducts
are
used,
they
shall
be of the same
cross°
sectional
area
as the free
area
of the openings
to which
they
connect.
The
minimum
short
side
dimension
of
rectangular
air
ducts
shall
not
be less
than
3 inches
(76.2
ram)+ See Figure
13+
OUTLET
AmR DUCT
Water Piping
,,%
Water
temperature
over
125°F
(52°C) can cause severe burns
instantly resulting in severe injup]
or death.
Children,
elderly,
and
the
physically
or mentally
disabled
are at highest risk for scald injury.
Feel
water
before
bathing
or
showering+
Temperature
limiting valves
are
available.
Read instruction manual for safe
temperature setting
HOTTER
WATER
CAN SCALD:
Water heaters
are intended
to produce
hot water.
Water heated
to a temperature
which
will
satisfy
space
heating,
clothes
washing,
dish washing,
cleaning
and other
sanitizing
needs
can scald
and permanently
injure
you upon
contact.
Some
people
are more likely
to be permanently
injured
by hot water
than others.
These
include
the elderly,
children,
the infirm,
or
physically/mentally
handicapped.
If anyone
using hotwaterin
your
home
fits into one of these
groups
or if there
is a local
code or state
law requiring
a certain
temperature
water
at the
hot water
tap, then
you
must
take
special
precautions.
In
addition
to using the lowest
possible
temperature
setting
that
satisfies
your
hot water
needs,
a means
such
as a *mixing
valve, shall be used at the hot water
taps used by these people
or at the ,water heater.
Mixing
valves
are available
at plumbing
supply
or hardware
stores.
See Figure
14. Valves
for reducing
point of use temperature
by mixing
cold and hot water
are also
available.
Follow
manufacturer's
instructions
for installation
of the valves.
Before
changing
the factory
setting
on the
thermostat,
read the Temperature
Regulation
section
in this
manual.
INLET A_R DUCT
FIGURE 13.
Louvers
and Grilles:
In calculating
free area,
consideration
shal!
be given
to the blocking
effect
of louvers,
grilles
or
screens
protecting
openings+
Screens
used
shall
not be
smaller
than
1/4 inch (6+4 mm) mesh.
If the free area through
a design
of louver
or grille
is known,
it should
be used
in
calculating
the size
opening
required
to provide
the free
area specified.
If the design
and free area is not known,
it
may
be assumed
that wood
louvers
will be 20°25
percent
free
area
and
metal
louvers
and grilles
will have
60°75
percent
free area.
Louvers
and grilles
shall
be fixed
in the
open
position
or interlocked
with the equipment
so that they
are opened
automatically
during
equipment
operation.
Special
Conditions
Created
by Mechanical
Exhausting
or
Fireplaces:
operation
of exhaust
fans,
ventilation
systems,
clothes
dryers
or fireplaces
may create
conditions
requiring
special
attention
to avoid unsatisfactory
operation
of installed
gas
utilization
equipment.
+MIXING
HOT WATER
VALVE
OUTLET
ON
WATER
HEATER
WATERHEATER
FIGURE14.
Toxic
Chemica!
Hazard
+ Do not connect
to non°potable
water system
12