The bladder in the stabilizer is to be preten- Before pumping other liquids - especially flammable, sioned on location. explosive and toxic media - Giant must be consulted with regard to the resistance of the pump material. It Depending on the lay-out of the plant, a pressure ac- cumulator may be necessary on the discharge side.
PARTS LIST - GP7142HTC ITEM PART DESCRIPTION QTY. ITEM PART DESCRIPTION QTY. 07665 Steel Ring 07600 Crankcase 04321-0100 Seal Case 05525 Head of Oil Dipstick 01009 O-Ring 13156 O-Ring 13000 Oil Filler Plug Assembly 04779 O-Ring 04791 Seal Sleeve 07601...
GP7142HTC REPAIR INSTRUCTIONS To Check Valves Unscrew hexagon screws (58). Take out tension spring (57), remove the complete valve (51) with either a valve tool or an M16 hexagon screw. Remove valve adaptor (56) and tension spring (57) with pull-out tool size 5.
GP7142HTC PUMP DIMENSIONS - MM (INCHES) GP7142HTC Torque Specifications Position Item# Description Lubrication Info Torque Specifications 07600 Crankcase Molycote/Cu-Paste 22706 Hexagon Screw 33 ft.-lbs. (45 Nm) 07109 Drain Plug 59 ft.-lbs. (80 Nm) 13182 Connecting Rod 30 ft.-lbs. (40 Nm)
Page 8
1. Five (5) years from the date of shipment for all pumps used in portable pressure washers with NON-SALINE, clean water applications. 2. Two (2) years from the date of shipment for Giant pumps used in car wash applications. 3. One (1) year from the date of shipment for all other Giant industrial and consumer pumps.