elsner elektronik KNX T-Objekt-UP Technical Data And Installation Notes

Temperature sensor

Advertisement

Temperature Sensor
KNX T-Objekt-UP
Elsner Elektronik GmbH Steuerungs- und Automatisierungstechnik
Herdweg 7 • D-75391 Gechingen • Germany
Phone: +49 (0) 70 56/93 97-0 • Fax: +49 (0) 70 56/93 97-20
info@elsner-elektronik.de • www.elsner-elektronik.de
Technical Data
and Installation Notes

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KNX T-Objekt-UP and is the answer not in the manual?

Questions and answers

Summary of Contents for elsner elektronik KNX T-Objekt-UP

  • Page 1 Temperature Sensor KNX T-Objekt-UP Technical Data and Installation Notes Elsner Elektronik GmbH Steuerungs- und Automatisierungstechnik Herdweg 7 • D-75391 Gechingen • Germany Phone: +49 (0) 70 56/93 97-0 • Fax: +49 (0) 70 56/93 97-20 info@elsner-elektronik.de • www.elsner-elektronik.de...
  • Page 2: Scope Of Delivery

    Socket ∅ 60 mm, 42 mm deep • Frame according to the switching programme used in the building • Cover according to the switching programme KNX T-Objekt-UP Temperature Sensor • Date of issue: 13/01/2010 • Technical changes reserved. Errors reserved.
  • Page 3: Technical Specifications

    EN 60730-1:2000 Section EMV (23, 26, H23, H26) • EN 50090-2-2:1996-11 + A1:2002-01 • EN 61000-6-1:2004 The product has been tested for the above mentioned standards by an accredited EMV laboratory. KNX T-Objekt-UP Temperature Sensor • Date of issue: 13/01/2010 • Technical changes reserved. Errors reserved.
  • Page 4: Installation And Commissioning

    Elsner Elektronik does not assume any liability for changes in standards after publication of this instruction manual. Installation position The KNX T-Objekt-UP will be installed concealed within a socket (∅ 60 mm, 42 mm deep) and fitted with a frame and cover from the switching programme used in the building.
  • Page 5: Front Side

    Composition Front side Programming LED Programming button for teaching instrument Rear view with connection Slot for KNX terminal BUS +/- KNX T-Objekt-UP Temperature Sensor • Date of issue: 13/01/2010 • Technical changes reserved. Errors reserved.
  • Page 6: Notes On Installation

    Sensor must not be exposed to water (rain) or dust. This could result in the electronic being damaged. A relative air humidity of 95% must not be exceeded. Avoid bedewing. KNX T-Objekt-UP Temperature Sensor • Date of issue: 13/01/2010 • Technical changes reserved. Errors reserved.

Table of Contents