Brightness and Presence Detectors
Item numbers
70670 Intra-Sewi KNX L-Pr, white
70672 Intra-Sewi KNX L-Pr, black
70680 Intra-Sewi KNX TH-L-Pr, white
70682 Intra-Sewi KNX TH-L-Pr, black
Installation and Ad justment

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Intra-Sewi KNX L-Pr and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for elsner elektronik Intra-Sewi KNX L-Pr

  • Page 1 Intra-Sewi KNX L-Pr and Intra-Sewi KNX TH-L-Pr Brightness and Presence Detectors Item numbers 70670 Intra-Sewi KNX L-Pr, white 70672 Intra-Sewi KNX L-Pr, black 70680 Intra-Sewi KNX TH-L-Pr, white 70682 Intra-Sewi KNX TH-L-Pr, black Installation and Ad justment...
  • Page 3: Table Of Contents

    5.0.7.6. Dehumidification and/or humidification ........56 5.0.8. Cooling medium temp. monitoring ............58 5.0.8.1. Threshold value ................58 Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 4 5.0.10.1.Block ....................64 5.0.10.2.Monitoring ..................64 5.0.11. Connection inputs of the OR logic ............. 67 Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 5 Clarification of signs Installation, inspection, commissioning and troubleshooting of the device must only be carried out by a competent electrician. This manual is amended periodically and will be brought into line with new software releases. The change status (software version and date) can be found in the contents footer. If you have a device with a later software version, please check www.elsner-elektronik.de in the menu area "Service"...
  • Page 6 Clarification of signs...
  • Page 7: Description

    Configuration is made using the KNX software ETS. The product file can be down- loaded from the Elsner Elektronik website on www.elsner-elektronik.de in the “Ser- vice” menu. 1.0.1. Scope of delivery • Sensor Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 8 -20°C … +60°C Resolution 0.1°C Accuracy* ±0.7°C at -20°C...-10°C ±0.5°C at -10°C...+60°C Humidity sensor (only Intra-Sewi KNX TH-L-Pr): Measurement range 0% rH … 100% rH Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 9: Measuring Accuracy

    The device may only be used as a fixed-site installation; that means only when assem- bled and after conclusion of all installation and operational start-up tasks and only in the surroundings designated for it. Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 10: Coverage Area Of The Motion Detector

    ETS in order to ensure the specified accuracy of the sensor (offset). 2.2.1. Coverage area of the motion detector Angle of coverage: approx. 94° × 82° Range: approx. 5 m Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 11: Installation In False Ceiling

    Place the device in the installation opening in the ceiling. For this, fold the clamps up- wards and guide the device through the installation opening with the clamps first. The device is automatically fixed by the clamps. Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 12: Installation In Connector Socket

    Clamp the device in the support ring so that the springs on the device snap over the tabs of the support ring. Fig. 3: Tragring Tabs Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 13: Back View: Connection

    The connection is made with the KNX terminal (red/black) to KNX TP. Fig. 5 Clamps for installation in false ceiling Springs for installation in sup- port ring KNX terminal Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 14: Front View: Programming And Addressing

    The brightness and movement sensor and the airing lamella must not get dirty or cov- ered. As a rule, it is sufficient to wipe the device with a soft, dry cloth twice a year. Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 15: Transfer Protocol

    Input -WC- [1.1] DPT_Switch 1 bit (1 = Start | 0 = Stop) Light controller: Dimmer incre- Input [5.1] DPT_Scaling 1 byte ments Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 16 Output R-CT Depending on setting 1 Bit - 4 Bytes Motion sensor: Master 1: Switch Input RWC- [7.5] 2 Bytes on delay DPT_TimePeriodSec Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 17 Output R-CT Depending on setting 1 Bit - 4 Bytes Motion sensor: Master 3: Switch Input RWC- [7.5] 2 Bytes on delay DPT_TimePeriodSec Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 18 Temperature sensor: measured Output R-CT [9.1] 2 Bytes value total DPT_Value_Temp Temperature sensor: measured Input -WC- [1.17] 1 Bit value min./max. query DPT_Trigger Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 19 -WC- [1.1] 1 Bit output block DPT_Switch 102 Temp. threshold value 4: Abso- Input / -WCT [9.1] 2 Bytes lute value Output DPT_Value_Temp Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 20 Input / -WCT [9.1] 2 Bytes ting Output DPT_Value_Temp 124 Temp.control: Setpoint Eco hea- Input -WC- [1.1] 1 Bit ting (1:+ | 0:-) DPT_Switch Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 21 -WC- [1.17] 1 Bit value min./max. reset DPT_Trigger 146 Humidity thresholdV 1: Abso- Input / -WCT [9.7] 2 Bytes lute value Output DPT_Value_Humidity Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 22 Input -WC- [7.5] 2 Bytes from 1 to 0 DPT_TimePeriodSec 168 Humidity thresholdV 4: Swit- Output R-CT [1.1] 1 Bit ching output DPT_Switch Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 23 DPT_Value_Amplitude 189 Absolute humidity [g/m³] Output R-CT [14.17] 4 Bytes DPT_Value_Density 190 Ambient climate status: 1=com- Output R-CT [1.1] 1 Bit fortable|0=uncomfort. DPT_Switch Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 24 1 Bit DPT_Bool 210 Logic input 5 Input -WC- [1.2] 1 Bit DPT_Bool 211 Logic input 6 Input -WC- [1.2] 1 Bit DPT_Bool Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 25 232 AND logic 3: 8 bit output B Output R-CT [5.010] DPT_- 1 Bit - Value_1_Ucount 2x1 Byte 233 AND logic 3: Block Input -WC- [1.1] 1 Bit DPT_Switch Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 26 252 OR logic 4: 8 bit output B Output R-CT [5.010] DPT_- 1 Bit - Value_1_Ucount 2x1 Byte 253 OR logic 4: Block Input -WC- [1.1] 1 Bit DPT_Switch Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 27: Parameter Setting

    The brightness reading can be corrected in order to compensate for a dull or bright point of installation for the sensor. Use reading correction No • Yes Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 28: Threshold Value 1/2/3/4

    Select whether the threshold value is to be specified per parameter or via a communi- cation object. Threshold value setpoint using Parameter • Communications object Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 29: Switching Output

    • on change to 1 and periodically • on change to 0 and periodically Cycle 5 s ... 2 h (if sent periodically) Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 30: Block

    • never point-actual difference, dimming increment • after power supply restoration and times • after power supply restoration and programming Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 31 •the actual value deviates from the setpoint value by more than X Lux Target / actual difference in % 1...100; 20 (for a deviation in %) Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 32 Value prior to initial communication 0 • 1 Output pattern On block • send nothing • send off command • send on command • send value Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 33 Activate the slave in order to use it. Use slave No • Yes When a motion is detected, the device periodically sends a 1 to the master via the bus. Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 34: Master 1/2/3/4

    • after power supply restoration and programming Select, whether motion is to be detected constantly or brightness dependent. Motion detection constantly • brightness dependent Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 35 Switch off sensor, at the earliest after a waiting period of seconds 0...600; 5 after motion detection and above measured brightness plus hysteresis in Lux 1...5000; 200 Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 36 • on change to movement and periodically • on change to no movement periodically Cycle 1s • 5 s • ... 2 h (if sent periodically) Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 37: Align Communication Between Master And Slave

    When the master performs a switch-off action, it simultaneously sends a message to the bus via the "master: slave cycle reset". . This message can be received by the slave Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 38 0.1°C • 0.2°C • 0.5°C • ... • 5.0°C (if sent on change) Send cycle 5 s • 10 s • ... • 2 h (if sent periodically) Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 39: Threshold Value 1, 2, 3, 4

    For units which have already been taken into service, the last communicated threshold value can be used. Basically, Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 40: Switching Output

    • on change to 0 and periodically Cycle 5 s • 10 s • 30 s… • 2 h (only if sending periodically is selected) Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 41: Block

    The parameter is only taken into consideration if the setting via object is activated below. Please note that the setting "After power supply restoration and pro- Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 42 (Default). Then configure a temperature control block via the blocking object. Mode after reset • Comfort • Standby • Eco • Building protection Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 43: General Setpoint Values

    • Dual-level heating + dual-level cooling General setpoint values You may enter separate setpoint values for each mode or use the comfort setpoint as a basic value. Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 44: Comfort Setpoint

    Starting heating/cooling setpoint (in 0.1 °C) -300…800; 210 valid until 1st communication (not upon saving the setpoint value after programming) Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 45: Standby Setpoint

    0…200; 30 (for heating) Increase cooling setpoint (in 0.1°C) 0…200; 30 (for cooling) Eco setpoint Eco mode is usually used for night mode. Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 46: Setpoint Values For Frost/Heat Protection (Building Protection)

    • common control variable are used for Level 1+2 Use control variable for 4/6-way valve No • Yes (only for common control variables in level 1) Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 47: Heating Control Level 1/2

    In case of a short reset time, the control responds with a fast increase of the control variable. In case of a long reset time, the control responds somewhat less Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 48 (if a value is sent) In case of a common control variable for heating and cooling, 0 is always transmitted as a fixed value. Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 49: Cooling Control Level 1/2

    • PI control Control variable is a • 1 bit object (for level 2 with 2-point controlling, no • 8 bit object common control variables) Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 50 When blocked, the control variable shall • not be sent • send a specific value Value (in %) 0...100 (if a value is sent) Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 51 Use external measured value No • Yes Ext. Reading proportion of the total reading 5% • 10% • ... • 50% • ... • 100% Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 52: Threshold Value 1, 2, 3, 4

    • after power supply restoration and programming Set the threshold value directly in the application program using parameters, or define them via the bus using a communication object. Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 53: Switching Output

    None • 1 s • 2 s • 5 s • 10 s • … • 2 h (If delay can be set via objects: valid until 1st communication) Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 54: Block

    Switching output sends on change to 1 and periodically if switching output = 0  send 0 Switching output sends on change to 0 and periodically Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 55: General Control

    Set, in which cases setpoint values received via object are to be retained. Please note that the setting "After power supply restoration and programming" should not be used Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 56: Dehumidification And/Or Humidification

    - dead zone value. Dehumidification and/or humidification Depending on the control mode, settings sections for humidification and dehumidifi- cation appear (level 1/2). Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 57 Activate the monitoring of the coolant temperature if required. The menus for setting the monitoring are displayed. Use monitoring of the coolant temperature No • Yes Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 58: Cooling Medium Temp. Monitoring

    (if sent on change) Send cycle 5 s • 10 s • 30 s • 1 min • … • 2 h (if sent periodically) Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 59: Switching Output

    • Send switching output status Switching output sends on change to 1 • Do not send message • if switching output = 1  send 1 Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 60 In this way, it is for example possible to monitor compliance with DIN 1946 (stan- dard values) or even to define your own comfort field. Use comfort field No • Yes Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 61 The chapter "Variable comparator" only applies to the TH-L-Pr model. The integrated variable comparators can output maximum, minimum and average values. Use comparator 1/2 No • Yes Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 62: Control Variable Comparator 1/2

    AND logic AND logic 1 not active • active AND logic ... not active • active AND logic 4 not active • active Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 63: Or Logic

    0 … 255 / 100% / 360° / 63; 0 if logic = 0 Output value object B 0 … 255 / 100% / 360° / 63; 0 if logic = 0 Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 64: 1.Block

    • 1 + 2 + 3 • 1 + 2 + 4 • 1 + 3 + 4 • 2 + 3 + 4 • 1 + 2 + 3 + 4 Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 65 Temperature sensor malfunction ON Temperature sensor malfunction OFF Humidity sensor malfunction ON Humidity sensor malfunction OFF Motion detector test output Motion detector test output inverted Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 66 Cooling 1 temperature controller inactive Cooling 2 temperature controller active Cooling 2 temperature controller inactive Humidity controller dehumidification 1 active Humidity controller dehumidification 1 inactive Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 67: Connection Inputs Of The Or Logic

    Switching output AND logic 2 inverted Switching output AND logic 3 Switching output AND logic 3 inverted Switching output AND logic 4 Switching output AND logic 4 inverted Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 68 Parameter setting Sensors Intra-Sewi KNX TH-L-Pr and Intra-Sewi KNX L-Pr • Version: 30.08.2018 • Technical changes and errors excepted.
  • Page 69 Elsner Elektronik GmbH Control and Automation Engineering Sohlengrund 16 75395 Ostelsheim Phone +49 (0) 70 33 / 30 945-0 info@elsner-elektronik.de Germany +49 (0) 70 33 / 30 945-20 www.elsner-elektronik.de Technical support: +49 (0) 70 33 / 30 945-250...

This manual is also suitable for:

Intra-sewi knx th-l-pr

Table of Contents