CORNING E62-HPRU Installation Manual

High-power remote unit supporting cellular technologies on fiber optic cable using the cpri protoco;

Advertisement

Quick Links

1.
2.
GENERAL INFORMATION
The E62-HPRU is a high-power remote unit supporting cellular technologies on fiber optic
cable using the CPRI protocol. The HP is ideal for multioperator multiband deployments of
cellular services in large coverage areas. The HP supports up to 43 dBm output per band in
single 2T2R or dual 1T1R up to 80 MHz per band. The HP converts an optical signal to RF
and then transmits at the relevant 3GPP band and receives the analog RF signal, conditions
it, and converts it back to optical for routing to the E2 or A2.
This document describes the installation procedure for the E62-HP unit.
This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and
QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC
License to operate this device. NOTE: Only authorized person can enter the area where the
antenna is installed. And the person is fully aware of the potential for exposure and can exercise
control over his or her exposure by leaving the area or by some other appropriate means.
Awareness of the potential for RF exposure in a workplace or similar environment can be provided
through specific training as part of a RF safety program.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
Corning Optical Communications
High-Power (E62-H2)
Installation Manual
Everon™ 6200
Installation Manual | CMA-793-AEN | Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E62-HPRU and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CORNING E62-HPRU

  • Page 1 Everon™ 6200 GENERAL INFORMATION The E62-HPRU is a high-power remote unit supporting cellular technologies on fiber optic cable using the CPRI protocol. The HP is ideal for multioperator multiband deployments of cellular services in large coverage areas. The HP supports up to 43 dBm output per band in single 2T2R or dual 1T1R up to 80 MHz per band.
  • Page 2: Table Of Contents

    Accessories List ..........................23 Rack Installation ..........................24 Wall Installation ..........................29 EU-O Mounting Dimension Spacing ...................... 32 Installing the High Power Remote Unit (HPRU) ..................33 Accessories List ..........................33 Corning Optical Communications Installation Manual | CMA-793-AEN | Page 2...
  • Page 3 Single Port Bidirectional SFP Transceiver ................... 46 Dual Port SFP Transceiver ........................ 46 Optical Indicator ..........................47 AU Optical Port Description ......................... 48 EU-O Optical Port Description ......................49 RU Optical Port Description ......................... 50 Corning Optical Communications Installation Manual | CMA-793-AEN | Page 3...
  • Page 4: Preface

    Low path loss cables connected to antennas are highly recommended. In accordance with wireless service provider standards it is not advised to use digital repeaters as a signal source for Corning solutions. Antenna gain should not exceed 12.5 dBi. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 4...
  • Page 5: Site Considerations

    Storage Temperature range: -25°C to +70°C DC Power Connections Referring to the diagram, connect the power cables as follows: Higher voltage wire linked to cable / Lower voltage wire linked to BLUE cable. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 5...
  • Page 6 Connect “-” to a low potential (0 VDC from a +48 VDC power supply; -48 VDC from a -48 VDC power supply) Cable Core Cable Length Maximum Expandable Length 14 AWG 10 m Corning Optical Communications Installation Manual | CMA-793-AEN | Page 6...
  • Page 7: Warning Marks

    ALWAYS disconnect all lines and power connections before servicing or disassembling this equipment. NEVER touch the surface after the device's power is turned on. For performance and safety reasons, NEVER disassemble and remodel the devices. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 7...
  • Page 8: Unpacking And Inspecting

    Verify that the contents and quantities agree with the Delivery Packing List. Check the device model against the Delivery Packing List. Notify CORNING immediately if any discrepancies are discovered, to verify whether the complete and correct shipment has been received.
  • Page 9: Inspecting The Device

    Maintain 3U clearance from the top surface of the device to the top of the rack.  Fan Cooling: You can mount the fan between the bottom of the device and any other. Maintain 2U clearance between the bottom of the device and any other. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 9...
  • Page 10 Maintain 150 mm clearance from the top of the device to any other planar obstructions. Maintain 150 mm clearance from both sides of the device to any other planar obstructions. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 10...
  • Page 11: Installing The Access Unit (Au)

    3. Installing the Access Unit (AU) Accessories List Corning Optical Communications Installation Manual | CMA-793-AEN | Page 11...
  • Page 12: Rack Installation

    To install the Access Unit (AU) in the equipment rack. Attach the 19-inch mounting brackets at the front of the AU, using 4 screws M3×6 per bracket and the Phillips screwdriver. Observe the orientation of the brackets. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 12...
  • Page 13 Recommended attaching the sliding rails to rack. (Not included in delivery). Place the AU in the rack and secure the AU using 2 screws M6×16 on both side and the Phillips screwdriver. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 13...
  • Page 14 It is necessary to allow at least 3 rack units (132 mm) of free space below each unit for heat dissipation without fan installed or 1 rack unit (44 mm) of free space below each unit with fan occupied in the middle. Otherwise, the device temperature may rise and affect the service life of the device. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 14...
  • Page 15 Connect and lock the power cable at the AU rear side. Connect and screw the ground wire at the AU rear side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 15...
  • Page 16: Fan Installation

    Fan Installation 1. Secure the Fan using 2 screws M6×16 on both sides and the Phillips screwdriver 2. Plug AC power lead. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 16...
  • Page 17 3. Fan DC version has power cable embedded in chassis. Note: Red is for positive; Blue is for negative. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 17...
  • Page 18: Wall Installation

    To install the Access Unit (AU) on the wall: Rotate the handles 90°and attach them at the rear of the AU, using 4 screws M3×6 per bracket and the Phillips screwdriver. Observe the orientation of the brackets. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 18...
  • Page 19 Mark 4 x ∅6.8mm drilling holes sites for the hanger to be attached to the wall. Drill 4 holes at the marked sites using percussion drill and embed 4×∅10 plastic expansion pipes. Note: H = 70 mm. Fasten the case with 4×M6 expansion bolt. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 19...
  • Page 20 Connect and lock the power cable at the AU rear side. Connect and screw the ground wire at the AU rear side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 20...
  • Page 21: Au Mounting Dimension Spacing

    AU Mounting Dimension Spacing Corning Optical Communications Installation Manual | CMA-793-AEN | Page 21...
  • Page 22: Rf Connection

    Description Module 4 Duplexer Interface QMA Female Module 3 Duplexer Interface QMA Female Module 2 Duplexer Interface QMA Female Module 1 Duplexer Interface QMA Female Electric Power Line Interface Grounding Corning Optical Communications Installation Manual | CMA-793-AEN | Page 22...
  • Page 23: Installing The Expansion Unit (Eu-O)

    4. Installing the Expansion Unit (EU-O) Accessories List Corning Optical Communications Installation Manual | CMA-793-AEN | Page 23...
  • Page 24: Rack Installation

    To install the Expansion Unit in the equipment rack. Attach the 19-inch mounting brackets at the front of the EU, using 4 screws M3×6 per bracket and the Phillips screwdriver. Observe the orientation of the brackets. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 24...
  • Page 25 Corning Optical Communications Installation Manual | CMA-793-AEN | Page 25...
  • Page 26 Recommended attachment of the sliding rails to rack. (Not included in delivery). Place the EU in the rack and secure the EU using 2 screws M6×16 on both sides and the Phillips screwdriver. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 26...
  • Page 27 It is necessary to allow at least 2 rack units (88 mm) of free space below each unit for heat dissipation without fan installed or 1 rack unit (44 mm) of free space below each unit with fan occupied in the middle. Otherwise, the device temperature may rise and affect the service life of the device. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 27...
  • Page 28 5. Connect and lock the power cable at the EU rear side. 6. Connect and screw the ground wire at the EU rear side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 28...
  • Page 29: Wall Installation

    To install the Expansion Unit (EU) on the wall: Rotate the handles 90°and attach them at the rear of the EU, using 4 M3×6 screws per bracket and the Phillips screwdriver. Observe the orientation of the brackets. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 29...
  • Page 30 Mark 4 x ∅6.8 mm drilling holes sites for the hanger to be attached to the wall. Drill 4 holes at the marked sites using percussion drill and embed 4×∅10 plastic expansion pipes. Note: H = 70 mm. Fasten the case with 4×M6 expansion bolt. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 30...
  • Page 31 Connect and lock the power cable at the AU rear side. Connect and screw the ground wire at the AU rear side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 31...
  • Page 32: Eu-O Mounting Dimension Spacing

    EU-O Mounting Dimension Spacing Corning Optical Communications Installation Manual | CMA-793-AEN | Page 32...
  • Page 33: Installing The High Power Remote Unit (Hpru)

    5. Installing the High-Power Remote Unit (HPRU) Accessories List Corning Optical Communications Installation Manual | CMA-793-AEN | Page 33...
  • Page 34: Wall Installation (Back On The Wall)

    Attach and fasten the handle to the side of HPRU with screws M6×14 using T5 Wrench. Attach and fasten the Bracket I to the back of HPRU with screws M6×14 using T5 Wrench. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 34...
  • Page 35 Mark the position of the drilling holes in the mounting Bracket II. Note: R = 13 mm. Drill 4 holes at the marked positions. Note: H = 70 mm Corning Optical Communications Installation Manual | CMA-793-AEN | Page 35...
  • Page 36 Tips: Use Bracket II as a reference to control each devices’ separation distance before hanging and locking HPRU up. Hang the HPRU on the mounting Bracket II and fasten with nuts M10. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 36...
  • Page 37 Fasten the Bracket I and II with screws M6×14. Connect and lock the power cable at the HPRU rear side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 37...
  • Page 38 Connect and screw the ground cable at the HPRU’s left side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 38...
  • Page 39: Wall Installation (Side On The Wall)

    Attach and fasten the handle to the side of HPRU with screws M6×14 using T5 Wrench. Attach and fasten the Bracket I to the left side of HPRU with screws M6×14 using T5 Wrench. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 39...
  • Page 40 Mark the position of the drilling holes in the mounting Bracket II. Note: R = 13 mm. Drill 4 holes at the marked positions. Note: H = 70 mm. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 40...
  • Page 41 Tips: Use Bracket II as a reference to control each devices’ separation distance before hanging and locking HPRU up. Hang the HPRU on the mounting Bracket II and fasten with nuts M10. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 41...
  • Page 42 Fasten the Bracket I and II with screws M6×14. Connect and lock the power cable at the HPRU rear side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 42...
  • Page 43 Connect and screw the ground cable at the HPRU left side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 43...
  • Page 44: Pole Installation

    Connect the ground cable and power cable. Extra accessories are required for pole installation and purchased separately. Note: The diameter of Pole shall not be over 110 mm or less than 55 mm. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 44...
  • Page 45: Hpru Mounting Dimension Spacing

    HPRU Mounting Dimension Spacing Corning Optical Communications Installation Manual | CMA-793-AEN | Page 45...
  • Page 46: Optical Connection

    B. The optical receiver and transmitter terminals of the optical module can be determined by the triangular mark on the optical module. The triangular mark in the yellow box and the red and blue lines indicate the optical fiber connections. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 46...
  • Page 47: Optical Indicator

    Check whether both indicators turn green after connecting one pair of optical modules. If the indicators are red, the terminal has not synchronized. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 47...
  • Page 48: Au Optical Port Description

    Connects WLAN network adapters for monitoring device through Wi-Fi STATUS Indicates device operating status DEBUG Connects local debugging PC through a USB connection ALARM I/O Connects external environment alarm interface for environment monitoring Corning Optical Communications Installation Manual | CMA-793-AEN | Page 48...
  • Page 49: Eu-O Optical Port Description

    Connection for local PC through CAT-5 for local monitoring Connection for WLAN Network adapters for monitoring device through Wi-Fi DEBUG Connection for local debugging PC through USB wire STATUS Indicates device operating status Corning Optical Communications Installation Manual | CMA-793-AEN | Page 49...
  • Page 50: Ru Optical Port Description

    Connection for RU at the next lower level Master Indicates Master OP port operating status Indicates device operating status DEBUG Connection for local PC through CAT-5 for local monitoring Wi-Fi signal output port Electrical Power Line Interface Corning Optical Communications Installation Manual | CMA-793-AEN | Page 50...
  • Page 51 Corning Optical Communications products without prior notification. A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. © 2021 Corning Optical Communications. All rights reserved. CMA-793-AEN /July 2021...