Page 1
Awareness of the potential for RF exposure in a workplace or similar environment can be provided through specific training as part of a RF safety program. Corning Optical Communications User Manual | E62-H2 | Page 1...
All the following “Safety Precautions” must be observed during the entire installation and operation of the Everon 6200system. The Everon 6200 system components are designed for maximum safety and reliability when they are installed, used, and maintained by trained and qualified technicians in accordance with the procedures and instructions contained in this manual.
Page 5
L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Corning Optical Communications User Manual | E62-H2 | Page 5...
Storage Temperature range: -25° C to +70° C DC Power Connections Referring to the diagram, connect the power cables as follows: Higher voltage wire linked to cable / Lower voltage wire linked to BLUE cable. Corning Optical Communications User Manual | E62-H2 | Page 7...
Page 8
Connect “-” to a low potential (0 VDC from a +48 VDC power supply; -48 VDC from a -48 VDC power supply) Cable Core Cable Length Maximum Expandable Length 14 AWG 10 m Corning Optical Communications User Manual | E62-H2 | Page 8...
ALWAYS disconnect all lines and power connections before servicing or disassembling this equipment. NEVER touch the surface after the device's power is turned on. For performance and safety reasons, NEVER disassemble and remodel the devices. Corning Optical Communications User Manual | E62-H2 | Page 9...
Verify that the contents and quantities agree with the Delivery Packing List. Check the device model against the Delivery Packing List. Notify CORNING immediately if any discrepancies are discovered, to verify whether the complete and correct shipment has been received.
Maintain 3U clearance from the top surface of the device to the top of the rack. Fan Cooling: You can mount the fan between the bottom of the device and any other. Maintain 2U clearance between the bottom of the device and any other. Corning Optical Communications User Manual | E62-H2 | Page 11...
Page 12
Maintain 150 mm clearance from the top of the device to any other planar obstructions. Maintain 150 mm clearance from both sides of the device to any other planar obstructions. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 10...
To install the Access Unit (AU) in the equipment rack. Attach the 19-inch mounting brackets at the front of the AU, using 4 screws M3×6 per bracket and the Phillips screwdriver. Observe the orientation of the brackets. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 12...
Page 15
Recommended attaching the sliding rails to rack. (Not included in delivery). Place the AU in the rack and secure the AU using 2 screws M6×16 on both side and the Phillips screwdriver. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 13...
Page 16
It is necessary to allow at least 3 rack units (132 mm) of free space below each unit for heat dissipation without fan installed or 1 rack unit (44 mm) of free space below each unit with fan occupied in the middle. Otherwise, the device temperature may rise and affect the service life of the device. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 14...
Page 17
Connect and lock the power cable at the AU rear side. Connect and screw the ground wire at the AU rear side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 15...
Fan Installation 1. Secure the Fan using 2 screws M6×16 on both sides and the Phillips screwdriver 2. Plug AC power lead. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 16...
Page 19
3. Fan DC version has power cable embedded in chassis. Note: Red is for positive; Blue is for negative. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 17...
To install the Access Unit (AU) on the wall: Rotate the handles 90° and attach them at the rear of the AU, using 4 screws M3×6 per bracket and the Phillips screwdriver. Observe the orientation of the brackets. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 18...
Page 21
Mark 4 x ∅6.8mm drilling holes sites for the hanger to be attached to the wall. Drill 4 holes at the marked sites using percussion drill and embed 4×∅10 plastic expansion pipes. Note: H = 70 mm. Fasten the case with 4×M6 expansion bolt. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 19...
Page 22
Connect and lock the power cable at the AU rear side. Connect and screw the ground wire at the AU rear side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 20...
To install the Expansion Unit in the equipment rack. Attach the 19-inch mounting brackets at the front of the EU, using 4 screws M3×6 per bracket and the Phillips screwdriver. Observe the orientation of the brackets. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 24...
Page 27
Recommended attachment of the sliding rails to rack. (Not included in delivery). Place the EU in the rack and secure the EU using 2 screws M6×16 on both sides and the Phillips screwdriver. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 25...
Page 28
It is necessary to allow at least 2 rack units (88 mm) of free space below each unit for heat dissipation without fan installed or 1 rack unit (44 mm) of free space below each unit with fan occupied in the middle. Otherwise, the device temperature may rise and affect the service life of the device. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 26...
Page 29
5. Connect and lock the power cable at the EU rear side. 6. Connect and screw the ground wire at the EU rear side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 27...
To install the Expansion Unit (EU) on the wall: Rotate the handles 90° and attach them at the rear of the EU, using 4 M3×6 screws per bracket and the Phillips screwdriver. Observe the orientation of the brackets. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 28...
Page 31
Mark 4 x ∅6.8 mm drilling holes sites for the hanger to be attached to the wall. Drill 4 holes at the marked sites using percussion drill and embed 4×∅10 plastic expansion pipes. Note: H = 70 mm. Fasten the case with 4×M6 expansion bolt. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 30...
Page 32
Connect and lock the power cable at the AU rear side. Connect and screw the ground wire at the AU rear side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 31...
Attach and fasten the handle to the side of H2RU with screws M6×14 using T5 Wrench. Attach and fasten the Bracket I to the back of H2RU with screws M6×14 using T5 Wrench. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 34...
Page 36
Mark the position of the drilling holes in the mounting Bracket II. Note: R = 13 mm. Drill 4 holes at the marked positions. Note: H = 70 mm Corning Optical Communications Installation Manual | CMA-793-AEN | Page 35...
Page 37
Tips: Use Bracket II as a reference to control each devices’ separation distance before hanging and locking H2RU up. Hang the H2RU on the mounting Bracket II and fasten with nuts M10. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 36...
Page 38
Fasten the Bracket I and II with screws M6×14. Connect and lock the power cable at the H2RU rear side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 37...
Page 39
Connect and screw the ground cable at the H2RU’s left side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 38...
Attach and fasten the handle to the side of H2RU with screws M6×14 using T5 Wrench. Attach and fasten the Bracket I to the left side of H2RU with screws M6×14 using T5 Wrench. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 39...
Page 41
Mark the position of the drilling holes in the mounting Bracket II. Note: R = 13 mm. Drill 4 holes at the marked positions. Note: H = 70 mm. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 40...
Page 42
Tips: Use Bracket II as a reference to control each devices’ separation distance before hanging and locking H2RU up. Hang the H2RU on the mounting Bracket II and fasten with nuts M10. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 41...
Page 43
Fasten the Bracket I and II with screws M6×14. Connect and lock the power cable at the H2RU rear side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 42...
Page 44
Connect and screw the ground cable at the H2RU left side. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 43...
Connect the ground cable and power cable. Extra accessories are required for pole installation and purchased separately. Note: The diameter of Pole shall not be over 110 mm or less than 55 mm. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 44...
B. The optical receiver and transmitter terminals of the optical module can be determined by the triangular mark on the optical module. The triangular mark in the yellow box and the red and blue lines indicate the optical fiber connections. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 46...
Check whether both indicators turn green after connecting one pair of optical modules. If the indicators are red, the terminal has not synchronized. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 47...
Connects WLAN network adapters for monitoring device through Wi-Fi STATUS Indicates device operating status DEBUG Connects local debugging PC through a USB connection ALARM I/O Connects external environment alarm interface for environment monitoring Corning Optical Communications Installation Manual | CMA-793-AEN | Page 48...
Connection for local PC through CAT-5 for local monitoring Connection for WLAN Network adapters for monitoring device through Wi-Fi DEBUG Connection for local debugging PC through USB wire STATUS Indicates device operating status Corning Optical Communications Installation Manual | CMA-793-AEN | Page 49...
Connection for RU at the next lower level Master Indicates Master OP port operating status Indicates device operating status DEBUG Connection for local PC through CAT-5 for local monitoring Wi-Fi signal output port Electrical Power Line Interface Corning Optical Communications Installation Manual | CMA-793-AEN | Page 50...
Page 52
—Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Corning Optical Communications Installation Manual | CMA-793-AEN | Page 51...
Need help?
Do you have a question about the Everon 6200 and is the answer not in the manual?
Questions and answers