Contents Technical Specs Parts Description Helpful Tools and In the Box Installation Maintenance Warranty and Contact Important Notes • Please read fully and carefully before installing. Subject to change without notice. • The Hot+Cold Hydrant should be installed by a qualified professional. Follow all applicable regulations and building codes.
Page 3
33 -140 °F Certifications ASSE 1019C, ASME A112. 1 8. 1 , CSA B125. 1 Operating Water Pressure 25-125 PSI Warranty Limited lifetime all Aquor Hydrants Plumbing Compatibility PEX A and valves, 5 years all other products and parts Hydrant Material 316L Stainless Steel, Polymers www.aquorwatersystems.com...
Page 4
Rear Hydrant Barrel x4 Wedge Mounting Screws x2 Front Hydrant O-Rings x2 PEX Inlet and Pressure Relief Valve Front Hydrant and Control Knob HC1-006 Hydrant Sleeve x2 Hydrant Screws HC1-006-EL Hydrant Sleeve x4 Faceplate Screws EPDM Plug Cover (Removal Optional)
® Helpful Tools and in the Box ASSE 1019C, ASME A112.18.1, CSA B125.1 CERTIFIED Helpful Tools 4 mm 1/2" In the Box HC1-006 x2 M5 x .8 mm x4 #10 HC1-006-EL Remove inlets before installation Removal optional Mounting Template 6 in x 6 in www.aquorwatersystems.com...
Page 6
Aquor Hot+Cold Hydrant ® Installation ASSE 1019C, ASME A112.18.1, CSA B125.1 CERTIFIED Find vertically level install surface and turn off water 3 - 1/2” Install Hydrant body within a heated Entry hole is off-center vertically, use space to ensure freeze protection included template to find correct position.
Page 7
Aquor Hot+Cold Hydrant ® Installation ASSE 1019C, ASME A112.18.1, CSA B125.1 CERTIFIED If needed, reattach elbow inlets, then connect to plumbing, follow manufacturer's instructions 4 mm Ensure Hydrant body is within a heated space for freeze protection Test function Check for leaks www.aquorwatersystems.com...
Have an issue? Contact us. We're happy to help! ® and operational. They are treated with an FDA Aquor offers a limited lifetime warranty for all Aquor approved lubricant where needed. The hydrant Hydrants and valves and a 5-year limited warranty requires no scheduled maintenance to provide a for all other products and parts.
Page 9
Aquor Hot+Cold Hydrant ® 03/25 Servicing Guide Helpful Tools 3 mm (8 inch arm length) 2.5 mm 1.5 mm Front Serviceable Components Email us at contact@aquorwatersystems.com or call us at (800) 458-1749 for replacement parts. 1. EPDM Plug Cover 7. Ceramic Mixing Cartridge 13.
Page 10
Aquor Hot+Cold Hydrant ® 03/25 Servicing Guide Disassembly Diagnose problem BEFORE disassembling Shut off water, drain hydrant Remove x4 faceplate screws, set aside 2.5 mm Remove x6 rear hydrant body screws, Remove front hydrant and control knob set aside 3 mm...
Page 11
Aquor Hot+Cold Hydrant ® 03/25 Servicing Guide Reassembly Inspect rear hydrant body O-rings, Insert rear hydrant body into lubricate or replace as needed sleeve using guide pins Secure rear hydrant body screws, Align control knob to the center of the...
Page 12
Aquor Hot+Cold Hydrant ® 03/25 Mounting Template This Side Up 3 - 1/2 in 6 in x 6 in Have Questions? We’re here to help Monday to Friday 9AM-4PM PST contact@aquorwatersystems.com (800) 458-1749.