Spitwater SW151 Operating & Maintenance Manual

Electric hot water high pressure cleaner
Hide thumbs Also See for SW151:

Advertisement

Quick Links

Electric Hot Water
High Pressure Cleaner

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SW151 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Spitwater SW151

  • Page 1 Electric Hot Water High Pressure Cleaner...
  • Page 2 SPARE PARTS, ACCESSORIES AND AFTER SALES SERVICE Spitwater has an extensive range of spare parts and accessories to suit all your cleaning needs. For spare parts, accessories and service please contact 1800 SPITWATER (1800 774 892) and to view Spitwater's extensive range of high pressure cleaners online visit www.spitwater.com.au...
  • Page 3: Technical Data

    TECHNICAL DATA MODEL SW151 SW151 SW151 PRODUCT SHW68 SHW68/B SHW68S UNIT PERFORMANCE FLOW RATE PRESSURE PRESSURE NOZZLE OUTLET WATER TEMP MAX °C WATER INLET PRESSURE MAX TEMP MAX °C ELECTRICAL VOLTAGE PHASE FREQUENCY PLUG CONNECTED LOAD RATED CURRENT CLASS IP PROTECTION...
  • Page 4: Description Of Symbols

    DESCRIPTION OF SYMBOLS The following symbols are used throughout this instruction booklet in order to mark important paragraphs or sections that require particular attention. Their meaning is listed next to them for your attention. The following symbols are used on the unit in order to warn user of potential injury if not cautious. Their meaning is listed next to them for your attention.
  • Page 5 SAFETY LABELS, UNIT COMPONENTS FEATURES & CONTROLS • Always pay attention to the safety instructions provided on each label. Do not alter or remove safety labels CHEMICAL TANK POWER PLUG (SHW68 & SHW68/S ONLY) PRESSURE BURNER PRESSURE GAUGE SWITCH HIGH / LOW TEMPERATURE UNIT ON / OFF CHEMICAL FLOW...
  • Page 6: General Safety Precautions

    GENERAL SAFETY PRECAUTIONS 1. OBSERVE SAFETY INSTRUCTIONS • Make sure you have read and understood the whole instruction manual before installing, operating or carrying out any maintenance on this unit. • Warnings and serial label on the unit provide important directions and information on the safe use of the unit.
  • Page 7 4. EXTENSION CORD • If using an extension cord make sure it is according to cross section / maximum length requirements as shown to the right. • Inadequate extension cords can be dangerous. If an extension cord is used, it shall be suitable for outdoor use, and the connection has to be kept dry and off ground.
  • Page 8: Chemical Hazard

    • Refuel in a well ventilated and open area. When fuel and/or lubricants are spilled clean immediately. • DO NOT mix fuel. Incorrect fuels shall not be used as they may prove hazardous. • Use only clean and approved fuel, store in appropriate containers and dispensers 9.
  • Page 9: Operational Safety Precautions

    OPERATIONAL SAFETY PRECAUTIONS All health and safety regulations applicable to general safe work practices, as well as safe operation of equipment, as well as any specific standard for safe operation of high pressure cleaners according to local regulations must be followed. When operating this unit, 1.
  • Page 10: Equipment Safety

    Never exceed the maximum working temperature and pressure as indicated on the unit data plate and in this manual. • Only use this unit with cleaning chemicals recommended by Spitwater. The use of other cleaning agents or chemicals may adversely affect the safety of the unit. •...
  • Page 11: Storage / Transport

    4. When not in use the unit must be stored in a dry building where there is no possibility for the temperature to be at or below 0°C. If necessary to store the unit at or below 0°C contact your authorized Spitwater service agent for advice.
  • Page 12: Plug Assembly

    6. Replace the red oil travel plug fitted on the for any damage, leaks or other issues. If any pump with the yellow dipstick supplied in the problem is found, contact your Spitwater agent accessories bag. immediately. 3. Identify the unit from the information on the serial label affixed to the unit.
  • Page 13: Nozzle Assembly

    10. NOZZLE ASSEMBLY Connect the high pressure nozzle (smaller hole) and the low pressure nozzle (larger hole) to the lance. Do not over tighten and make sure that the nozzle positions do not interchange during assembly. Add nozzle shield after nozzle assembly. Refer diagram below. 11.
  • Page 14: Water Inlet Connection

    Contact your Spitwater agent for advice and /or supply. • Make sure the water supply temperature and pressure meet the values specified in the technical data, then turn the water supply on. Visually check for leaks and contact your Spitwater service agent if found. •...
  • Page 15 14. Remove the DIESEL tank cap and fill the diesel tank with clean filtered diesel. ONLY USE CLEAN DIESEL IN THIS UNIT, as using any other fuel will create a risk of explosion and damage to the unit.
  • Page 16: Usage Tips

    CHECK LIST” in the SERVICE / CARE section as a guide. If the unit is damaged or faulty in anyways, DO NOT use it and immediately contact your authorized Spitwater service agent for advice. TO START 3. Check that the pressure indicated on the pressure 1.
  • Page 17: Hot Water Mode

    2. Turn the temperature adjustment knob to achieve PRESSURE ADJUSTMENT HIGH / LOW desire cleaning temperature. To activate high pressure turn the lance handle clockwise and pull the trigger and to activate low pressure turn the lane handle anti-clockwise. HIGH 3.
  • Page 18 3. Open the chemical injector by turning the knob anti-clockwise until the desired affect is reached. When the trigger is pulled, water mixed with detergent will be sprayed. 4. If the unit is to be left unused for an extended period, be sure to clean the detergent line by running the water through it and dropping the 4.
  • Page 19: Safety Precautions

    2. Carry out all regular maintenance and Spitwater recommends that all maintenance is inspections as listed in this manual using carried out by an authorized Spitwater service original Spitwater parts where required. agent using original Spitwater spare parts. 3. Always make sure before carrying out any...
  • Page 20: Daily Inspection Checklist

    ● Clear fumes = ideal condition to run the unit. Assess any undue noise levels from the motor. STOP operting the unit, Unit is fit, proceed task Contact Spitwater service agent immediately Contact Spitwater service Do It Yourself, agent / Qualified person for...
  • Page 21 USAGE VS SERVICE FREQUENCY TABLE-A: Usage vs Service Frequency Time interval for checks and replacement listed above are for units subjected to normal operating conditions. Should the unit be subjected to abnormal conditions (e.g. heavy use, dirty water, extreme temperatures or conditions etc.) times should be reduced accordingly.
  • Page 22: Pump Oil Check

    OIL CHECK POINTS 1. Remove the fastening knobs at four places. PUMP OIL CHECK 3. Ensure the unit is on a flat surface. 4. Check the oil level in the pump using the dipstick or the sight glass on the back / side of the pump.
  • Page 23: Troubleshooting Guide

    TROUBLESHOOTING GUIDE If the fault cannot be identified or corrected using the below list (or remedy suggests contacting Spitwater service agent) stop using the unit immediately and contact your authorized Spitwater service agent to rectify. TROUBLESHOOTING GUIDE FAULT CAUSE REMEDY...

This manual is also suitable for:

Sw151s

Table of Contents