Page 2
SPARE PARTS, ACCESSORIES AND AFTER SALES SERVICE Spitwater has an extensive range of spare parts and accessories to suit all your cleaning needs. For spare parts, accessories and service please contact 1800 SPITWATER (1800 774 892) and to view Spitwater's extensive range of high-pressure cleaner’s online visit www.spitwater.com.au...
Page 3
TECHNICAL DATA MODEL HC11140P HC12180P PRODUCT SCW006 SCW007 #N/A UNIT PERFORMANCE FLOW RATE PRESSURE PRESSURE #N/A NOZZLE #N/A OUTLET WATER TEMP MAX #N/A °C WATER INLET PRESSURE MAX #N/A TEMP MAX #N/A °C ELECTRICAL (Electric units only) VOLTAGE PHASE FREQUENCY...
DESCRIPTION OF SYMBOLS The following symbols are used throughout this instruction booklet in order to mark important paragraphs or sections that require particular attention. Their meaning is listed next to them for your attention. The following symbols are used on the unit in order to warn user of potential injury if not cautious. Their meaning is listed next to them for your attention.
Page 5
SAFETY LABELS, UNIT COMPONENTS FEATURES & CONTROLS • Always pay attention to the safety instructions provided on each label. Do not alter or remove safety labels...
GENERAL SAFETY PRECAUTIONS 1. OBSERVE SAFETY INSTRUCTIONS • Make sure you have read and understood the whole instruction manual before installing, operating or carrying out any maintenance on this unit. • Warnings and serial label on the unit provide important directions and information on the safe use of the unit.
Page 7
4. EXTENSION CORD (Electric units only) • If using an extension cord make sure it is according to cross section / maximum length requirements as shown to the right. • Inadequate extension cords can be dangerous. If an extension cord is used, it shall be suitable for outdoor use, and the connection has to be kept dry and off the ground.
(non-drinkable). been installed, AS/NZS 60335.2.79. • For suction supply / non-pressure water supply, • Follow all local standards and regulations other than potable water mains, contact your applicable to water connection. authorized Spitwater service agent for advice.
OPERATIONAL SAFETY PRECAUTIONS All health and safety regulations applicable to general safe work practices, as well as safe operation of equipment, as well as any specific standard for safe operation of high-pressure cleaners according to local regulations must be followed. 1.
Never exceed the maximum working temperature and pressure as indicated on the unit data plate and in this manual. • Only use this unit with cleaning chemicals recommended by Spitwater. The use of other cleaning agents or chemicals may adversely affect the safety of the unit. •...
Page 11
4. When not in use the unit must be stored in a dry building where there is no possibility for the temperature to be at or below 0°C. If necessary to store the unit at or below 0°C contact your authorized Spitwater service agent for advice.
Page 12
2. Remove carton and carefully remove the unit from the pallet keeping it upright. Visually check for any damage, leaks or other issues. If any problem is found, contact your Spitwater agent immediately. 3. Identify the unit from the information on the serial label affixed to the unit.
Page 13
• High pressure hoses, fittings and couplings are important for the safety of the machine. Use only high-pressure hoses, couplings and fittings recommended by Spitwater. • Do not pull-on high-pressure hose in order to move the unit.
Page 14
If the unit is damaged or faulty in any way, DO NOT use it and immediately contact your authorized Spitwater service agent for TO USE advice. 1. Release the spray gun trigger lock.
USAGE TIPS: PRESSURE ADJUSTMENT HIGH / LOW • Use the unit as necessary to carry out cleaning 1. To activate high pressure pull the lance head while trying to minimize where possible inwards and to activate low pressure push the opening and closing the spray gun trigger as lance head outwards this will lead to premature wear of the parts.
Page 16
TO STOP USING CLEANING AGENT 1. Close the chemical injector by turning it clockwise until it stops. 1. If detergent is required it CAN BE USED IN LOW PRESSURE ONLY. 2. Turn the engine switch to the OFF position. 2. Use cleaning solution bottle. Only use a cleaning detergent approved by the manufacturer and do not use under any circumstance acid or corrosive products (contact an authorized service agent or the...
2. Carry out all regular maintenance and Spitwater recommends that all maintenance is inspections as listed in this manual using carried out by an authorized Spitwater service original Spitwater parts where required. agent using original Spitwater spare parts. 3. Always make sure before carrying out any...
Check for water leaks at high pressure connections Check exhaust fume colour, if dark there may be an issue Check for any unusual noises from the machine Contact Spitwater service Safe to use for assistance STOP, do not operate unit.
Page 19
USAGE VS SERVICE FREQUENCY Time interval for checks and replacement listed above are for units subjected to normal operating conditions. Should the unit be subjected to abnormal conditions (e.g., heavy use, dirty water, extreme temperatures or conditions etc.) times should be reduced accordingly. TABLE-A: Usage vs Service Frequency...
OIL CHECK POINTS ENGINE OIL CHECK PUMP OIL CHECK • Ensure the unit is on a flat surface. • Ensure the unit is on a flat surface. • Remove the oil level dipstick and wipe it • Check the oil level in the pump using the clean.
TROUBLESHOOTING GUIDE If the fault cannot be identified or corrected using the below list (or remedy suggests contacting Spitwater service agent) stop using the unit immediately and contact your authorized Spitwater service agent to rectify. TROUBLESHOOTING GUIDE FAULT CAUSE REMEDY...
Need help?
Do you have a question about the HC11140P and is the answer not in the manual?
Questions and answers