LG LV-B1861HL Owner's Manual
Hide thumbs Also See for LV-B1861HL:

Advertisement

Available languages

Available languages

Quick Links

This Owner's Manual is provided and hosted by Appliance Factory Parts.
LG LV-B1861HL
Owner's Manual
Shop genuine replacement parts for LG LV-B1861HL
Find Your LG Air Conditioner Parts - Select From 2328 Models
-------- Manual continues below --------

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LV-B1861HL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LG LV-B1861HL

  • Page 1 This Owner's Manual is provided and hosted by Appliance Factory Parts. LG LV-B1861HL Owner's Manual Shop genuine replacement parts for LG LV-B1861HL Find Your LG Air Conditioner Parts - Select From 2328 Models -------- Manual continues below --------...
  • Page 2: Installation Parts Provided

    CONVERTIBLE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS • Please read this instruction manual completely before installing the product. • When the power cord is to be replaced, replacement work shall be performed by authorized personnel only. • Installation work must be performed in accordance with national wiring standards by authorized personnel only.
  • Page 3: Table Of Contents

    OUT-LINE OF INSTALLATION 1.The following should be always observed for safety .......3 Installation works Installation Parts Required tools 2. Installation of Indoor, Outdoor unit 1) Selection of the best location... • • Installation Plate Level ..........4 • • Four Type “A” screws Screw driver 2) Indoor unit installation ....5 •...
  • Page 4: The Following Should Be Always Observed For Safety

    1. The following should be always observed for safety • Please report to or take consent by the supply authority before connecting to the system. • Be sure to read "THE FOLLOWING SHOULD BE ALWAYS OBSERVED FOR SAFETY" before installing the air conditioner. •...
  • Page 5: Installation Of Indoor, Outdoor Unit

    2. Installation of Indoor, Outdoor Unit 1. Selection of the best location More than 20cm 1) Indoor unit More than • There should not be any heat source or 20cm steam near the unit. • There should not be any obstacles to prevent More than eye-level the air circulation.
  • Page 6: Indoor Unit Installation

    2. Indoor unit installation Before Installing, prepare Installation Plates Side Plate • 'Installation Plates' are attached at the bottom of indoor unit. Detach them by removing each 3 screws at both sides. • Detach 'Side Plate (R,L)' by removing each 2 Install Plate screws on both sides.
  • Page 7 • Insert the nuts and washer onto the Anchor nut suspension bolts for locking the suspension Ceiling bolts on the ceiling. • Mount the suspension bolts to the anchor- Washer nuts firmly. Suspension bolts • Secure the Installation plates onto the Suspension bolts (adjust level roughly.) using nuts, washers and spring washers.
  • Page 8 CAUTION 1. Install declination of the indoor unit is very important for the drain of the convertible type air conditioner. 2. Minimum thickness of the insulation for the connecting pipe shall be 7mm. 3. If the Installation Plates are fixed to horizontal line, the indoor unit after installing will be declined to the bottomside.
  • Page 9 • Secure the unit to the Installation Plates with four M8 bolts and washers. • Before working, refer to "Connecting pipe and cable to Indoor Unit" on page 12. • Hook up the Inlet Grille Hook to the cabinet. Inlet hanger •...
  • Page 10: Installation On The Wall

    2) Installation on the Wall • Select and mark the position for fixing bolts and piping hole. Decide the position for fixing bolts slightly tilted to the drain direction after considering the direction of drain hose. • Drill the hole for anchor nut on the wall. •...
  • Page 11 Install the Indoor unit onto Installation Plate. Inner slot • Insert 2 hooks on the both left and right side of the unit to the inner slot (wall side) of the Installation Plate. • Secure the unit to the Installation Plate with four M8 bolts and washers.
  • Page 12: Installation On The Floor

    3) Installation on the floor From the left wall Installation of Mount Bracket. more than 760mm • Select and mark the position for Mount Brackets and the piping hole. • Drill the hole for the anchor nut on the wall. From the •...
  • Page 13: Connecting Pipes To The Indoor Unit

    3. Connecting Pipes to the Indoor Unit 3-1. Preparation of Piping Copper Main cause of gas leakage is defect in flaring Slanted Uneven Rough tube 90° work. Carry out correct flaring work in the following procedure. 1) Cut the pipes and the cable. Use the accessory piping kit or the pipes purchased locally.
  • Page 14: Installation On The Ceiling

    3-2. Installation on the ceiling 1) Connecting the pipes to the indoor unit The pipe can be connected to right side, bottom or back of the unit. 1. For the Right Side Piping • After bending an end of the connecting tube, align the center of the pipings and sufficiently Hose tighten the flare nut with fingers.
  • Page 15 3-3. Installation on the wall or floor 1) Connecting the pipes to the indoor unit 1. For the Right Rear Piping • Remove the knock-out at the back side of the Piping cabinet. • After bending an end of the connecting tube, align the center of the pipings and sufficiently Taping tighten the flare nut with fingers.
  • Page 16: Connecting Pipes To The Outdoor Unit

    4. Connecting Pipes to the Outdoor Unit 1) Connecting the pipes to the Outdoor unit 1. Align the center of the pipings and sufficiently tighten the flare nut with fingers. 2. Finally, tighten the flare nut with torque wrench until the wrench clicks. •...
  • Page 17: Connecting Cables Between Indoor Unit And Outdoor Unit

    6. Connecting Cables between Indoor Unit and Outdoor Unit 1) Connecting cables to the Indoor Unit 1) Remove the Air guide - L by loosening 2 screws after removing the Inlet grille from the Indoor unit. 2) Connect the wires to the terminals on the AIR GUIDE-L control board individually according to the outdoor unit connection.
  • Page 18: Connecting The Cable To Outdoor Unit

    3) Connecting the cable to Outdoor Unit Outdoor unit 1. Remove the Cover control from the unit by Terminal block loosening a screw. Connect the wires to the terminals on the Over 5mm control board individually as following. Holder for 2.
  • Page 19: Form The Pipings

    4) Form the pipings 1. Wrap the connecting portion of indoor Seal a small opening unit with the Insulation material and around the pipings secure it with two Plastic Bands. (for the with gum type sealer. right pipings) • If you want to connect an additional drain hose, the end of the drain-outlet should keep Taping distance from the ground.
  • Page 20: Pipes: Gas Side

    7. Air Purging of the Pipes and Indoor Unit The air which contains moisture remaining in the Outdoor unit refrigeration cycle may cause a malfunction on the compressor. 1. Remove the caps from the gas side and liquid Cover control side valves.
  • Page 21: Test Running

    8. Test running 1) Connection of power supply RESET 1. Connect the power supply cord to the independent power supply. • Circuit breaker is required. 2. Prepare the remote control. • Insert two batteries provided. Remove the battery cover from the RESET remote controller.
  • Page 22: Instrucciones De Instalación

    INSTRUCCIONES DE INSTALACIÓN DE LOS ACONDICIONADORES DE AIRE TIPO CONVERTIBLE • Antes de instalar el producto, sírvase leer íntegramente este manual de instrucciones. • El cable de interconexión a instalar entre las unidades interior y exterior debe estar aprobado por la normalización TÜV, u otra equivalente.
  • Page 23 BOSQUEJO DE LA INSTALACIÓN 1.Por razones de seguridad, observe siempre lo siguiente........3 Trabajo de instalación Componentes de instalacón Herramientas necesarias 2. Instalación de las unidades interior y exterior 1) Elección del mejor lugar ..4 • • Nivel. Pletinas de montaje 2) Instalación de la unidad interior..
  • Page 24: Por Razones De Seguridad, Observe Siempre Lo Siguiente

    1. Por razones de seguridad, observe siempre lo siguiente: • Sírvase comprobar que dispone de suficiente energía contratada del servicio público antes de conectar el acondicionador de aire. • No deje de leer este apartado “POR RAZONES DE SEGURIDAD, OBSERVE SIEMPRE LO SIGUIENTE”: antes de proceder a la instalación del acondicionador de aire.
  • Page 25: Instalación De Las Unidades Interior Y Exterior

    2. Instalación de las unidades interior y exterior 1. Elección del mejor lugar Más de 20cm 1) Unidad interior Más de • No debe haber estufa ni fuente de calor alguna en 20cm la vecindad de la unidad. • No deben existir obstáculos que impidan la Más alto que el circulación del aire.
  • Page 26: Instalación De La Unidad Interior

    2. Instalación de la unidad interior Antes de comenzar la instalación, tenga dispuestas las pletinas de montaje Pletina lateral • Las Pletinas de montaje van sujetas a la parte trasera de la unidad interior. Sepárelas, retirando los tres tornillos de cada una.
  • Page 27 • Inserte las tuercas de anclaje en los orificios Tuerca de anclaje practicados en el techo para los pernos de suspensión. Techo • Monte firmemente los pernos de suspensión con Tuerca sus tuercas y arandelas en las tuercas de anclaje. Arandela Perno de •...
  • Page 28 PRECAUCIÓN 1. La instalación inclinada de la unidad interior es muy importante para el drenaje en los acondicionadores de aire de tipo convertible. 2. El espesor mínimo del aislamiento de la tubería ha de ser de 7 mm. 3. Si las pletinas de montaje están puestas horizontalmente, al terminar la instalación la unidad interior debe quedar inclinada hacia atrás.
  • Page 29 • Monte la unidad en las pletinas de montaje con cuatro pernos M8 y sus arandelas. • Antes de proceder, consulte el apartado “Conexión de la tubería y el cable a la unidad interior” en la página 12. • Inserte la uñeta de la rejilla de la entrada Guía lateral de aire en la carcasa.
  • Page 30: Instalación En La Pared

    2) Instalación en la pared • Seleccione y marque la posición de los pernos de sujeción y la de la tubería. Marque la posición de los pernos de sujeción de modo que la unidad quede ligeramente inclinada hacia el costado donde entronca la manguera de drenaje.
  • Page 31 Instale la unidad interior en las pletinas de montaje. alojamiento interior • Inserte las uñetas laterales derecha e izquierda de la unidad, en el alojamiento interior (hacia la pared) de las pletinas de montaje. • Fije la unidad a la pletina de montaje con cuatro pernos M8 y sus arandelas.
  • Page 32: Instalación En El Suelo

    3) Instalación en el suelo Más de 760 mm hasta Instalación del soporte de montaje. la pared izquierda • Mida y marque en la pared la posición del soporte, de las pletinas de montaje y del orificio de la tubería. Más de 840 mm •...
  • Page 33: Preparacón De Los Tubos

    3. Empalme de las tuberías a la unidad interior 3-1. Preparación de los tubos Tubo La causa principal de fugas de gas son los defectos Torcido Desigual Basto de cobre 90° en el trabajo de abocardado. Lleve a cabo una labor correcta de abocardamiento en los pasos que siguen.
  • Page 34: Instalación En El Techo

    3-2. Instalación en el techo 1) Empalme de las tuberías a la unidad interior La tubería se puede empalmar por el lado derecho, por el fondo, o por detrás de la unidad. 1. Empalme de la tubería por el lado derecho Soporte •...
  • Page 35: Instalación En La Pared O En El Suelo

    3-3. Instalación en la pared o en el suelo 1) Empalme de las tuberías a la unidad interior 1. Empalme de la tubería por la parte trasera derecha Tuberías • Retire la protección de la parte trasera de la carcasa. •...
  • Page 36: Empalme De Tuberías A La Unidad Exterior

    4. Empalme de las tuberías a la unidad exterior 1) Empalme de las tuberías a la unidad exterior 1. Centre la tubería y apriete todo lo que pueda con los dedos la tuerca valona. 2. Seguidamente, apriétela con su llave dinamométrica hasta que ésta suene.
  • Page 37: Conexión De Los Cables Entre Las Unidades Interior Y Exterior

    6. Conexión de los cables entre las unidades interior y exterior 1) Conexión de los cables a la unidad interior 1) Desmonte la guía en "L" para el flujo de aire, soltando los tornillos que se descubren al retirar la rejilla de la toma de aire. 2) Conecte los hilos uno a uno a los terminales de la regleta de conexiones, de acuerdo con GUÍA EN "L"...
  • Page 38: Unidad Exterior

    3) Conexión del cable de la unidad exterior Unidad exterior 1. Retire la tapa de la regleta de conexiones, Regleta de conexiones aflojando el tornillo que la fija. Conecte de uno en uno los hilos de los cables a los Más de 5 mm terminales de la regleta, de la forma que sigue: •...
  • Page 39: Armar Las Tuberías

    4) Armar las tuberías. 1. Enrolle el material aislante alrededor de Selle un pequeño anillo las conexiones de la unidad interior y alrededor de las tuberías sujételo con dos tiras de plástico (caso con un sellador tipo goma. de tuberías a la derecha). •...
  • Page 40: Purga Del Aire De Las Tuberías Y De La Unidad Interior

    7. Purga del aire de las tuberías y de la unidad interior. El aire húmedo que pueda entrar en el Unidad exterior ciclo de refrigeración será causa del mal funcionamiento del compresor. 1. Retire los tapones de las tuberías de gas y de líquidos.
  • Page 41: Pruebas

    8. Pruebas 1) Conexión a la red 1 Conectar el cable de red a una toma RESET exclusiva de red. • Se necesita un disyuntor. 2. Preparación del mando a distancia. • Instalación de las dos pilas suministradas. Retire la tapa del compartimiento de pilas RESET del mando a distancia.