Download Print this page

Delta AC Motor Drives VFD-XXXE Getting Started Manual page 29

Delta electronics ac motor drives quick start manual

Advertisement

Pr.
Explanation
Group 12: Analog Input/Output Parameters for Extension Card
AI1 Function
12.00
Selection
AI1 Analog Signal
12.01
Mode
Min. AVI3 Input
12.02
Voltage
Min. AVI3 Scale
12.03
Percentage
Max. AVI3 Input
12.04
Voltage
Max. AVI3 Scale
12.05
Percentage
Min. ACI2 Input
12.06
Current
Min. ACI2 Scale
12.07
Percentage
Max. ACI2 Input
12.08
Current
Max. ACI2 Scale
12.09
Percentage
AI2 Function
12.10
Selection
AI2 Analog Signal
12.11
Mode
Min. AVI4 Input
12.12
Voltage
Min. AVI4 Scale
12.13
Percentage
Max. AVI4 Input
12.14
Voltage
Max. AVI4 Scale
12.15
Percentage
Min. ACI3 Input
12.16
Current
Min. ACI3 Scale
12.17
Percentage
Settings
23: Quick Stop (Only for VFD*E*C models)
24: Download/execute/monitor PLC Program
(PLC2) (NOT for VFD*E*C models)
25: Simple position function
26: OOB (Out of Balance Detection)
27: Motor selection (bit 0)
28: Motor selection (bit 1)
0: Disabled
1: Source of the 1st frequency
2: Source of the 2nd frequency
3: PID Set Point (PID enable)
4: Positive PID feedback
5: Negative PID feedback
0: ACI2 analog current (0.0 ~ 20.0mA)
1: AVI3 analog voltage (0.0 ~ 10.0V)
0.0 to 10.0V
0.0 to 100.0%
0.0 to 10.0V
0.0 to 100.0%
0.0 to 20.0mA
0.0 to 100.0%
0.0 to 20.0mA
0.0 to 100.0%
0: Disabled
1: Source of the 1st frequency
2: Source of the 2nd frequency
3: PID Set Point (PID enable)
4: Positive PID feedback
5: Negative PID feedback
0: ACI3 analog current (0.0 ~ 20.0mA)
1: AVI4 analog voltage (0.0 ~ 10.0V)
0.0 to 10.0V
0.0 to 100.0%
0.0 to 10.0V
0.0 to 100.0%
0.0 to 20.0mA
0.0 to 100.0%
English- 29
Factory
NOTE
Setting
0
1
0.0
0.0
10.0
100.0
4.0
0.0
20.0
100.0
0
1
0.0
0.0
10.0
100.0
4.0
0.0

Advertisement

loading